If you are looking for an underfloor design which we guarantee will have the heat pump at the centre of the system design, 
instead of as an add on, come and talk to us at Freedom HP.

All Hitachi heat pumps can now be registered for a 7-year parts warranty, covering only the Hitachi components. Any labour charges 
for replacing faulty parts are not covered. The Hitachi warranty does not cover, radiators, cylinders, UFH, valves, pumps etc. It is the 
role of the installer to offer a warranty to the end user covering the heating system including the heat pump. Your installer may offer 
you their own full parts labour and call out warranty as part of their maintenance agreement, but you need to discuss this with the 
installer / maintenance company. The warranty will be held by the end user at the address the unit is installed. It is important that 
a qualified engineer services the unit annually to maintain the warranty . It does not have to be the installer who does this, we can 
recommend engineers to do this if the installer does not want to do this work.

Your unit is not automatically registered for warranty, your installer needs to fill in a form Online at 

www.freedomhp.co.uk.

 

Once this is done a certificate and a maintenance book will be emailed to the applicant, please make sure you have a copy of this 
certificate, and proof of maintenance. Hitachi may ask for this when a warranty claim is made.

Installation Details

Your Name

 

Your email address

 

Outdoor model number

 

Outdoor serial number

 

You will find this on the side of the heat pump

Indoor unit model number

 

Date commissioned

 

/                  /

Name of Homeowner

 

End user email address

 

This is where the warranty certificate will be sent by Samsung

Installation address

 

Post code

 

Installation Details

Company name

 

Engineers name

 

Office telephone number

 

Is this your first Hitachi install? 

YES     /     NO

Date commissioned

 

Will you or your company 

  

be maintaining the Unit? 

YES     /     NO

If No, Freedom Heat Pumps will advise of an engineer who  
can do this

Install Photos

Please take at least 6 photos showing the outdoor unit, control 
box and cylinder cupboard

Pipe

 

We supply a high quality 16x2mm 
multilayer pipe, consisting of 5 layers of 
polyethylene, adhesive and aluminium. 
Typically rated at 95°C at 10bar, this 
strong flexible pipe is well suited to 
underfloor heating, and is manufactured 
within the EU.

Controls

At Freedom we provide a wide range of 
controls manufactured by leading brands 
such as Heatmiser, Danfoss and Reliance. 
On offer are basic dial thermostats to 
the latest digital phone app controlled 
products.

Manifolds

Our brass manifolds are made in 
Germany, and are supplied to us by Watts 
Industries. This premium product has 
individual flow meters, isolation ball 
valves, and is fitted with an auto air vent 
and pressure gauge to aid testing.

Plate Systems

Our plate system is generally used for a suspended floor. Insulation should be fixed 
flush with the top of the existing joists to prevent downward heat loss. Battens are 
fixed at 400mm centres at 90° to the existing joists. Aluminium trays are then laid 
and stapled into position and the underfloor heating pipe is pressed into the grooves 
within the trays.

The pipe warms the trays and the heat is spread across the floor. Chipboard or 
plywood can then be laid and fixed to the battens.

Overlay Systems

Overlay panels provide many advantages over other insulation products when used 
with warm water underfloor heating systems.

Our panel dimensions are 1250mm in length by 350mm in width and either 20mm or 
25mm high.

Screed Systems

A Screed System is where the underfloor heating pipes are incorporated within 
the solid floor structure. Staples, interlocking cliprail or castellation mats are 
fixed directly on to the floor insulation. At Freedom Heat Pumps, we can provide 
everything from staples to cliprail through to castellation mats in order to suit your 
project.

Quotations are provided without obligation, and a fully insured BS1264 compliant AutoCAD pipe layout can be prepared prior to 
delivery and installation. This affords the client an opportunity to approve our suggestions prior to final acceptance. 

Do you have a project which you would like us to provide a competitive underfloor heating quotation for?  

If so, please email [email protected] or call 02380 274 833

Содержание RASM Series

Страница 1: ...Air Source Heat Pump Installation and Maintenance Manual Model Numbers RASM Monoblocs RWM Splits RWD Combi pre plumbed RWH High temp ...

Страница 2: ...n in line with today s standards and put together a list of the kit required at your cost price Alternatively if you don t currently have a heat pump project but would like to become a heat pump installer and don t know where to start contact us on 02380 274833 or email us at sales freedomhp co uk and we can set you on the correct course Homeowners If you are the homeowner please ask your installe...

Страница 3: ...e at least 6 photos showing the outdoor unit control box and cylinder cupboard Pipe We supply a high quality 16x2mm multilayer pipe consisting of 5 layers of polyethylene adhesive and aluminium Typically rated at 95 C at 10bar this strong flexible pipe is well suited to underfloor heating and is manufactured within the EU Controls At Freedom we provide a wide range of controls manufactured by lead...

Страница 4: ...e notice of Your installer should have provided you with a room thermostat if you have radiators or a thermostat in every room if you have under floor heating They will tell you how to use these stats The heat pump will run when it gets a run signal from the thermostat It is not controlled by the Hitachi remote controller To turn on the heating all you need to do is turn up the thermostats to turn...

Страница 5: ...ature falls 5 degrees below its set point the unit will automatically switch to heating the cylinder This should take less than an hour Once set temperature is achieved the unit will go back to heating the house The hot water cylinder loses almost no heat 1 3 a degree an hour if no hot water is used An anti legionella disinfection operation will be completed at a 3am every Wednesday morning The un...

Страница 6: ...con informs about pump operation There are three available pumps on the system Each one is numbered and its corresponding number is displayed below to the pump icon when it is operating Heater step Indicates which of the 3 possible heater steps is applied on space heating DHW Heater Informs about DHW Heater operation If it is enabled Solar Combination with solar energy Compressor Compressor enable...

Страница 7: ... cylinder set the stat to 5 Maintenance procedure Stop the unit clean the water strainer in the unit you need a spanner and circlip pliers for this On Monoblocs test the concentration of the Anti freeze glycol in the system using a Glycol tester the level should be 25 If you don t have a glycol tester a glycol tester refractometer can be bought from your heat pump supplier or online Refill the uni...

Страница 8: ...er less than 100m from the outdoor unit The box is 360mm wide 490mm high 100mm deep Note the pump in the Monobloc can only manage a run of 10m at 28mm diameter copper each way to the header or cylinder Header Buffer or Heat Exchanger Pump Z1 Z1 Z2 The 3 port valve MUST go A to DHW and B to Heating Flow Return at Heat Pump Return from Header Return from Heating Flow out of Header Flow into Header He...

Страница 9: ...ect live to 32 and Neutral to 34 the orange and grey wires are not used If a low loss header or buffer is used you can connect a buffer sensor in 8 and 9 Before power up Monobloc Dip Switches when using mirror box In the outdoor unit on the right hand pcb set DSW 4 Pin 1 up to activate indoor unit wiring box You also need to set SSW1 to Local push it down Instead of remote On the Monobloc mirror b...

Страница 10: ... pipe between the indoor and outdoor units with refrigeration pipework Pipe Sizes Outdoor Unit Yutaki M Indoor Unit Model Pipe Size Model Pipe Size Gas Pipe Liquid Pipe Gas Pipe Liquid Pipe 3 6 HP Ø 15 88 5 8 Ø 9 52 3 8 3 0 6 0 HP Ø 15 88 5 8 Ø 9 52 3 8 Pipe Limits Outdoor Unit HP 4 5 6 Maximum piping length between outdoor unit and indoor unit Lmax Actual piping length L 75m Equivalent piping len...

Страница 11: ...Z1 Z2 Flow Return at Heat Pump Return from Header Return from Heating Flow out of Header Flow into Header The 3 port valve MUST go A to DHW and B to Heating Power the Hitachi system needs 2 power supplies Immersion heater is connected to 31 Live and 30 Neutral Communication cable connect to the control box terminals 1 and 2 Remote controller connect to 3 and 4 Cylinder sensor connect this using 5 ...

Страница 12: ...aki M Indoor Unit Model Pipe Size Model Pipe Size Gas Pipe Liquid Pipe Gas Pipe Liquid Pipe 2 HP Ø 12 7 1 2 Ø 6 35 1 4 2 0 HP Ø 15 88 5 8 Ø 6 35 1 4 2 5 HP Ø 6 35 1 4 2 5 HP Ø 9 52 3 8 3 6 HP Ø 15 88 5 8 Ø 9 52 3 8 3 0 6 0 HP Ø 15 88 5 8 Ø 9 52 3 8 Note on the 2 and 2 5HP units run the pipes as per outdoor unit the indoor comes with adaptors to suit the pipework H Before power up On the indoor cir...

Страница 13: ... for 15m of pipework each way The additional refrigerant charge required is Size 2 add 30g m after 15m Size 3 add 40g m after 15m Size 4 add 60g m after 15m Size 6 add 60g m after 15m If the pipe length is under 5m set DSW2 pin 1 up to on If the pipe length is over 30M set DSW2 pin 2 to up on When delivered the indoor unit expansion valves are fully closed To open the valve you must apply power to...

Страница 14: ...Heating and Hot Water Combi Combi Installation Combi Installation Before power up On the indoor circuit board set the following switches DSW 4 Pin 5 needs to set pushed up DSW 4 Pin 3 push to up to enable immersion heater Note before the unit will run the expansion valve dip switch needs to be set by the fridge engineer If the pipe length is under 5m set DSW2 pin 1 up to on If the pipe length is o...

Страница 15: ... 8 HP Ø 25 4 1 1 18 Ø 9 52 3 8 8 HP Ø 25 4 1 1 18 Ø 9 52 3 8 10 HP Ø 12 7 1 2 10 HP Ø 12 7 1 2 Note on the 2 and 2 5HP units run the pipes as per outdoor unit the indoor comes with adaptors to suit the pipework Pipe Limits Outdoor Unit HP 2 2 5 3 4 5 6 8 10 Maximum piping length between outdoor unit and indoor unit Lmax Actual piping length L 50m 75m 70m Equivalent piping length 70m 95m 90m Minimu...

Страница 16: ...40V ac The run signal goes into 14 Remove the link Pump Z1 Live 14 and Neutral 34 on a combi wire live to 36 3 port connect live to 32 and Neutral to 34 the orange and grey wires are not used If a low loss header or buffer is used you can connect a buffer sensor in 8 and 9 Wiring Diagram Heating and Hot Water Split Pump Z1 Remote Controller Heating run signal from stat or ufh 3 port Monobloc split...

Страница 17: ...5 3 bar maximum In Monobloc units only Using the power fill the system with water and 25 Propylene Glycol Setting up the cylinder immersion heater To avoid the immersion heater cutting out before the legionella function is complete you have to set the stat in the immersion heater to 65 C minimum on a Telford cylinder set it to 5 Powering Up Makes sure all your room thermostats are off and all unde...

Страница 18: ...oll to Heat Pump OK 3 Water Pump Configuration OK 4 Minimum off time Change to 0 mins 5 Minimum on time change to 0 mins 6 Overrun time change to 0 mins 7 Press return x2 On all units Adjust the weather comp 8 In system configuration ok 9 Space heating ok 10 Circuit 1 ok 11 Water calculation mode ok 12 OTC gradient shows go left to points 13 In points graph pressing down highlights the water temp ...

Страница 19: ...ump details OK flow rates is listed Flow must be 7l min or 0 4m3 hr on size 2 and 3 units 14l min 0 8m3 hr on size 4 5 and 6 units and 25l min or 1 5m3 hr on size 8 and 10 units A 70 also shows on the PCB Starting the System in hot water mode On the controller scroll left highlight Heating C1 press power to turn this off With everything off the indoor PCB will say oF Scroll right highlight DHW pre...

Страница 20: ...ation from the unit going into the house All external pipework has to be insulated to meet MCS standards Mounting feet the outdoor units need to be mounted 100mm above the ground we recommend using rubber feet with unistrut channel These come with mounting bolts included Splits have 2 feet monos have 3 feet An expansion vessel pressure gauge pressure relief valve and filling loop All Hitachi units...

Страница 21: ... supply a 2 core 0 75mm 2 core flex from 3 and 4 in the remote controller to 3 and 4 in the control box Maximum distance is 100m The cylinder sensor is 1m long you need to connect this using 0 75mm flex 2 core to terminals 5 and 6 in the control box and into the cylinder in the top of the cylinder It must install above the immersion heater You must fix it so it can t be pulled out of the cylinder ...

Страница 22: ...1 Menu 2 System configuration press OK 3 Complimentary heating press OK 4 Automatically populates Heating source Monobloc will say HP Boiler Splits and combi will say HP EH Boiler 5 Boiler combination press OK 6 Adjust Bivalent point to your desired bivalent point or 3 C 7 Combination mode Parallel 8 Waiting time 5 min In this config the boiler will run IF the ambient is below the Bi Valent point ...

Страница 23: ...at Pumps Ltd All rights reserved Specifications and designs are subject to change without notice Non metric weights and measurements are approximate All data were deemed correct at time of creation All brand product service names and logos are trademarks and or registered trademarks of their respective owners and are hereby recognized and acknowledged v031218 ...