FRANKLINWH aGate X Скачать руководство пользователя страница 2

                                                                                                QUICK INSTALLATION GUIDE (FHP)

 
 

 

©2022 FranklinWH Energy Storage Inc. All rights reserved

.

 

All  information  in  this  Manual  is  subject  to  the  copyright  and  other  intellectual  property  rights  of 
FranklinWH Energy Storage Inc. This manual may not be modified, copied or reproduced, in whole or 
in part, without the prior written permission of FranklinWH Energy Storage Inc.

 

Please visit 

www.franklinwh.com/support

 

for the latest Franklin Home Power documents.

 

All  brands  and  trademarks  mentioned  in  this  document  are  the  property  of  their  respective 
owners, and their use in this document does not imply the sponsorship or recognition of their 
products or services.   

Please  read  this  document  carefully  to  ensure  the  best  reliability  of  the  product  and  your 
warranty eligibility. For further information about warranty, please refer to

 

the

 Franklin Home 

Power Limited Warranty

.

 

This document is intended for use by professional installation and maintenance service providers 
only  and  no  statements,  information  or  recommendations  in  this  document  constitute  any 
express or implied warranty. 

 

Please  read  this  document  carefully  before  installing  or  using  the  Franklin  Home 
Power equipment.  Failure  to  follow any  instructions  or warnings  in this document 
may  result  in  damage  to  the  equipment,  personal  electric  shock,  severe  injury,  or 
even death. 

Product Information 

Franklin Home Power (FHP) is composed of aPower, aGate and other electrical components, and 
this document applies only to the following products: aPower X and aGate X. 

FranklinWH 

Energy Storage Inc.

 

(“FranklinWH”) reserves the right to make a

ny improvements to 

the  product,  and  the  contents  in  this  document  shall  be  subject  to  updates  without  further 
notification. 

All images and pictures provided in this Manual are only for demonstration purposes and may 
differ in detail from the product, based on the product version. 

Feedback

 

If you have any questions or give us advice, please send us an email at: 

[email protected]

 

Disposal of Scrapped Products

 

Scrapped  products  (including  their  internal  chemicals  and  electrical  materials)  should  not  be 
disposed  of  with  household  wastes.  Please  refer  to  your  local  laws  and  regulations  regarding 
disposal. 

 

Содержание aGate X

Страница 1: ...Franklin Home Power Quick Installation Guide Version 1 0 Issued on September 28 2022...

Страница 2: ...n or recommendations in this document constitute any express or implied warranty Please read this document carefully before installing or using the Franklin Home Power equipment Failure to follow any...

Страница 3: ...loth keep aPower X and aGate X well protected from hard objects that may damage their exterior appearance or body during the handling and installation Torque Requirements Screws and their correspondin...

Страница 4: ...X installation area should be kept in a dry cool well ventilated The aPower X and aGate X installation area should be protected from access by children and away from any source of heat and or fire wa...

Страница 5: ...be a minimum clearance of 5D D is the outer diameter of electrical conduits from the top of aPower X to the ceiling When the aPower X is mounted on the wall the recommended distance between the botto...

Страница 6: ...nerator 98 4ft 30m aGate X to Router 328 1ft 100m External CT 16 4ft 5m DANGER Avoid drilling holes in the water pipes and cables buried in the wall WARNING Cover the aPower X top heat dissipation hol...

Страница 7: ...it 3 80A Backup load terminals 160A Grid terminal 200A Combiner box terminal 30A Wireless module aPower terminal Generator assembly terminal Bonding jumper Grid relay Reserved generator relay location...

Страница 8: ...6 combination screws fastening the inner panel counterclockwise to remove the screws Remove the aGate X inner panel and properly store it Remove the Door Use a 2X4 Phillips head screwdriver Turn the...

Страница 9: ...buried in the wall WARNING Cover the aPower X top heat dissipation hole to protect from gravel dust during drilling Based on the preplanned installation position and electrical conduit arrangement th...

Страница 10: ...Remove the water proof lock using an adjustable wrench turn the lock nut counterclockwise until the lock is removed If a signal cable hole is needed remove the lower plug WARNING Connect cables in ac...

Страница 11: ...shown in the figure Solution Use steel spacers to the same thickness of the baseboard for the upper part of the bracket Solution Use plywood or gypsum board to level the wall The recommended thicknes...

Страница 12: ...QUICK INSTALLATION GUIDE FHP 10 Breaker and Optional Parts Standard configuration Full configuration Smart Circuits Module optional Generator Module optional...

Страница 13: ...he home network cable with an internet connection into the Eth2 port of the EMS module in order to enable the remote communications function Wireless module EMS module Com Kit 4G Wifi WARNING Use only...

Страница 14: ...the matching terminal on the last aPower X NOTE If the communications cable shares the same conduit with power wires please use a Type 600V TC insulated communication cable with metal connector When t...

Страница 15: ...Bonding Part V when installed as service equipment the neutral and ground should be bonded together as shown in the picture on the left The Neutral Ground Bonding Jumper must only be removed if not in...

Страница 16: ...enerator breaker L1 and L2 will swap sides for connections L2 is located to the left while L1 is to the right NOTE If aluminum cable is used the cable connectors need to be treated using antioxidant I...

Страница 17: ...QUICK INSTALLATION GUIDE FHP 15 aPower X connections to the aGate X One aPower X unit L1 L2 Neutral Ground...

Страница 18: ...nnections to the aGate X 2 to 3 aPower X units WARNING The WAGO terminals of each aPower X can only be connected using 10AWG power wire aPower X 2 Connection aPower X 3 Connection L1 L2 Ground Neutral...

Страница 19: ...e aGate X When connecting more than 3 aPower X units to the aGate X use one 1 pair for the aPower X input from the combiner box and one 1 for the backup main panel output WARNING The WAGO terminals of...

Страница 20: ...IDE FHP 18 Re install the aPower X cover Install aPower X grills aGate X Panel re installation Two installers will be needed to re install the aGate X door Remove the knockouts Install the inner panel...

Страница 21: ...rilling holes in the water pipes and cables buried in the wall WARNING Cover the aPower X top heat dissipation hole to protect from gravel dust during drilling aPower X 1 aPower X 2 aPower X N N 15 aG...

Страница 22: ...igns into their account to set the FHP parameters b Bind homeowner email account to the FHP Step 4 Log into the Homeowner Account The main page of the FranklinWH App displays the real time data of the...

Отзывы: