PROBLEM
CAUSE
SOLUTION
8. Salty water after regeneration
A. Injectors or screen plugged
A. Clean or replace injectors and
screen
B. Restricted drain flow control
B. Clean drain line flow control
C. Brine valve sticking
C. Replace brine valve assembly
D. Brine tank is overfilled
D. See Problem # 7
E. Rinse cycle too short
E. Lengthen rinse cycle
9. Water leaks to drain continuously
A. Foreign material in control valve
A. Remove and inspect piston and
seal kit. Replace as necessary
B. Drive motor stopped during
regeneration cycle
B. Check for obstruction in piston and
seals. Replace drive motor.
C. Control valve continuously cycling
C. See Problem #10
D. Internal valve seal leak
D. Replace seals and/or piston
10. Control valve continuously cycling
A. Faulty homing switch
A. Replace homing switch
11. Resin in service line
A. Softener installed backwards
A. Verify supply water is plumbed to
inlet of softener by putting inlet
bypass handle in the SHUTOFF
position (Figure 4, Page 7) and
advancing the control valve to a
backwash position and unplugging
power from the control valve. If the
backwash flow rate does not
diminish, the unit is plumbed in
backwards.
B. Hot water backed up from water
heater has melted internal
components
B. Replace all damaged components
12. Meter fails to register flow
A. External bypass or cross connect in
plumbing
A. Test for external bypass by putting
inlet bypass handle in the
SHUTOFF position (Figure 4, Page
7) and open a treated faucet. If it
does not trickle to a stop, locate the
open bypass or cross connect and
correct it.
B. Meter cable unplugged at meter
module or circuit board
B. Plug in meter cable.
C. Meter turbine not securely snapped
into meter axel
C. Remove meter module and snap
securely onto axel and reinstall or
replace if unable to snap in place.
D. Meter module pushed too far into
valve body outlet
D. Pull meter module very slightly back
in the valve body outlet.
13. Call Error
A. Wires for drive motor or
microswitches are unplugged
A. Verify drive motor and microswitch
wires are connected correctly
B. Circuit board needs reset
B. Turn on both VAC and ECO lights
then unplug power for 10 seconds
and plug power back in.
14. Call Error and/or softener stuck in
DRAW cycle at 0:00 countdown
A. Defective component in powerhead
assembly:
Drive cam, microswitch position,
seal & spacer cartridge, piston
A. Replace powerhead assembly or
individual components