STEP 4: Plumb vent. Plumb vent using 2" threaded pipe to fitting in basin cover. 

Use pipe joint compound on threads and hand tighten only on plastic fittings. 

The basin must be vented in accordance with state and local codes. The vent 

is essential for proper switch operation and must not be omitted or restricted. 

CAUTION: Do not use a mechanical vent with this product. A mechanical vent 

will cause improper operation of the automatic switch.
STEP 5: Test unit. Connect power cord to electrical supply as stated under 

“Electrical Connections.” Secure power cord to piping with ties or tape. Fill unit 

with water through inlet. Pump should turn on with 7"–10" of water in tank, and 

turn off when 2"–5" of water is left in tank.

MAINTENANCE

Maintenance operations consist of cleaning basin and limited pump mainte-

nance. WARNING: Before any maintenance is performed, shut off water inlet 

and disconnect power cord from electrical supply outlet. Pump may become 

hot in operation. Allow pump to cool before servicing.
BASIN: Sediment may build up in basin causing pump to operate improperly. 

Remove (10) 1/4-20 screws from cover. Remove cord grommet and loosen cords 

to allow slack and then remove cover.
Remove pump and clean basin using a mild detergent and water. Reassemble 

in reverse order.
Torque screws 18-20 in.-lbs.
PUMP: Sediment or lint can clog pump and cause improper operation. If neces-

sary, remove pump from basin and remove the screws that hold the base plate 

and screen to motor housing. Remove baseplate and screen and clean impeller 

and volute passage. Do not use strong solvent on impeller. Clean using a mild 

detergent and water and reinstall. See pump manual for other information. For 

any other pump repair, return the pump to a Little Giant authorized service center.
FOR TROUBLESHOOTING INFORMATION, SEE PUMP OWNERS MANUAL 

INCLUDED WITH WRS-9EN BASIN KIT.
Instructions for replacement of RVMS Pump Switch (C/N 599261) 
STEP 1: CAUTION –
 make certain that the unit is disconnected from the power 

source before attempting to service or rework any components. 
STEP 2: Disconnect unit from inlet pipe, vent pipe, and discharge pipe.
STEP 3: Remove the 14 machine screws (Figure 2, Item #8) from around the 

basin cover.
STEP 4: Take off basin cover and remove cord grommet (Figure 2, Item #1).
STEP 5: Remove RVMS Pump Switch cord from the cord grommet. 
STEP 6: Loosen the stainless steel clamp that attaches the RVMS Pump Switch 

to the discharge pipe (Figure 2, Item #4).
STEP 7: Slide the RVMS Pump Switch up and off the discharge pipe. Be careful 

to note the switch's orientation for re-assembly.
STEP 8: Trim 1.25" from the replacement RVMS Pump Switch stem, as is 

detailed in Figure 4. Orientate the rubber grommet approximately 1.5" from the 

newly cut bottom of the switch stem.
STEP 9: Clean out the basin to ensure maximum product performance. 

Replace the RVMS Pump Switch in the reverse order in which it was removed.

2

Figure 3

Rubber Grommet
Passe-Fils en Caoutchouc 
Arandelas Aislantes de Caucho

Remove Stem Material
Enlever le MatÈriel de Tige
Quite el Tallo la Materia

1.50 ± .25

Cut Dimension

1.25

Figure 4

Power Cord Piggyback Plug

Cordon d'Alimentation avec 

Prise Mixte 

Cable Eléctrico con Enchufe 

Incorporado

*Items Not Included with WRS-9EN Basin Kit

*Articles Non Inclus avec Kit de Bassin WRS-9EN

*Los Articulos No Incluyeron con Juego de Palangana WRS-9EN

*2" Union 

*2 po Raccord 

*2" Unión

*2" vent pipe

*2" tuyau de ventilation 

*2 tubo de ventilación

*Intake

*Prise 

*Toma

Cover O-Ring

Couvercle avec joints toriques

Cubierta O-Ring

Basin

Bassin

Cubeta

Check valve

Clapet anti-retour

Válvula de Retención

Discharge pipe

Tuyau de refoulement

Tubería de descarga

On Level 7"-10" • Marche: 7"-10"

• En el Nivel 7"-10"

Off Level 2"-5" • Arrêt 2"-5"

• Del Nivel 2"-5"

TYPICAL INSTALLATION • INSTALLATION TYPIQUE • INSTALACION TÍPICA

*Union

*Raccord 

*Unión

*Items Not Included with WRS-9EN Basin Kit

*Articles Non Inclus avec Kit de Bassin WRS-9EN

*Los Articulos No Incluyeron con Juego de Palangana WRS-9EN

Pump

La Pompe 

La Bomba

Basin Cover • Bassin Couvercle • Cubeta Unión

Discharge pipe

Tuyau de refoulement

Tubería de descarga

1-1/2" Discharge pipe

1-1/2 po Tuyau de refoulement

1-1/2"  Tubería de descarga

Incluye un adaptador liso 
de 2" x 1-1/2" MNPT 
por si es requerido

2" slip x 1-1/2" MNPT 
adapter provided. 
Use if required.

15.68"

14.50"

10.63"

14.75"

Inlet of Basin is 1-1/2" FNPT

L'Arrivée de Cuvette est 1-1/2" FNPT

Entrada de Palangana es 1-1/2" FNPT

1-1/2" slip x 2" MNPT 

adapter is provided if a 

1-1/2" vent is required.

Au cas d'un event de 1-1/2", 

un adaptateur a glissement 

de 1-1/2" x 2" MNPT est fourni.
Incluye un adaptador liso 

de 1-1/2" x 2" MNPT 

para ventilación de 1-1/2".

2" slip X 1-1/2" MNPT 

adapter provided. 

Use if required.

Un adaptateur à glissement 

de 2" x 1-1/2" MNPT 

est fourni

Incluye un adaptador liso 

de 2" x 1-1/2" MNPT 

por si es requerido

Un adaptateur à glissement 
de 2" x 1-1/2" MNPT 
est fourni

SPECIFICATIONS • CARACTERISTIQUES • ESPECIFICACIONES

Item No.

Article

Articulo

Model No. 

N° du 

Modèle 

Numero de 

Modelo

Volts 

Voltage 

Voltios

Hertz 
Hertz 

Hertzios

Amps 

Ampères 

Amperios

Watts 
Watts 

Vatios

Gallons Per Min. (GPM) @ Ht. 

Gallons/Min. (GPM) @ Hauteur 

Galones Por Minuto @ Altura

Shutoff (Ft.) 

Tête d'arrêt 

(Pieds) 

cabeza de 

cierre (Pies)

Max. PSI 
Max. PSI 
Máx. PSI

5'

10'

15'

20'

25'

509268

WRS-9EN

115

60

9.0

920

80

70

60

45

25

32

14.1

Содержание Little Giant WRS-9EN

Страница 1: ...s Be sure electrical connections cannot be reached by rising water Under no circumstances should outlet box or receptacle be located where it may become flooded or submerged by water INSTALLATION All plumbing must meet local codes A licensed plumbing contractor is recom mended All fixtures connected to the WRS 9EN Basin Kit must be vented accord ing to state and local codes STEP 1 Determine proper...

Страница 2: ...itch s orientation for re assembly Step 8 Trim 1 25 from the replacement RVMS Pump Switch stem as is detailed in Figure 4 Orientate the rubber grommet approximately 1 5 from the newly cut bottom of the switch stem Step 9 Clean out the basin to ensure maximum product performance Replace the RVMS Pump Switch in the reverse order in which it was removed 2 Figure 3 Rubber Grommet Passe Fils en Caoutch...

Страница 3: ...ccord du couvercle Il est recommandé d utiliser un clapet de non retour pour éviter le refoulement de l eau dans le puisard Installer le clapet de non retour aussi près que possible de la partie supérieure du bassin afin d éviter le fonctionnement cyclique de la pompe S assurer que le clapet de non retour est installé dans le sens du débit Si le clapet de non retour est installé à l envers l eau n...

Страница 4: ...arte superior de la cubeta como sea posible para evitar el ciclo de la bomba Asegúrese de instalar la válvula de retención en la dirección correcta del flujo Si se instala la válvula de reten ción al revés no saldrá agua de la unidad Asegúrese de sellar la tubería de descarga con compuesto para juntas de tubería y de no exceder la altura de elevación de la bomba Sólo apriete los accesorios de plás...

Отзывы: