VCC-20S, ULS CONDENSATE PUMP SERIES
Owner's Manual
This condensate pump automatically removes condensate water that drips from an air conditioner evaporator
coil, refrigeration equipment coil, condensing furnace, or condensing boiler. The pump is controlled by a float
switch mechanism, which automatically starts and stops the pump.
This pump also includes an auxiliary high-water level switch. This switch is configured
to open a thermostat circuit in the event of high water level in the pump reservoir,
thereby stopping production of condensate. Alternatively, this switch can be reconfig
-
ured by the installer to close a circuit in the event of high water level, which operates
an external alarm or relay, (purchased separately).
Please examine your item(s) carefully to ensure that no damage occurred during ship
-
ment. If damage has occurred, please contact the place of purchase. They will assist
you in replacement or repair, if required.
This product is covered by a Limited Warranty for a period of 12 months from the date of original purchase by the
consumer. For complete warranty information, refer to
www.LittleGiant.com
.
Specifications
Model
Volts
HZ
Amps
Watts
Shut Off
VCC-20ULS
115
60
1.5
93
20’ (6.1 m)
VCC-20ULS
230
50/60
0.6/0.5
75
17’ (5.2 m)
SAFETY INSTRUCTIONS
Before Getting Started
This equipment should be installed and serviced by technically
qualified personnel who are familiar with the correct selection
and use of appropriate tools, equipment, and procedures. Failure
to comply with national and local electrical and plumbing codes
and within Little Giant recommendations may result in electrical
shock or fire hazard, unsatisfactory performance, or equipment
failure.
Know the product’s application, limitations, and potential haz
-
ards. Read and follow instructions carefully to avoid injury and
property damage. Do not disassemble or repair unit unless
described in this manual.
Refer to product data plate(s) for additional precautions, operat
-
ing instructions and specifications.
Failure to follow installation or operation procedures and all
applicable codes may result in the following hazards:
Risk of death, personal injury, or
property damage due to explosion, fire,
or electric shock.
•
Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc.
•
Do not use in explosive atmospheres or hazardous loca
-
tions as classified by the NEC, ANSI/NFPA70.
•
Do not handle a pump or pump motor with wet hands or
when standing on a wet or damp surface, or in water.
•
When a pump is in its application, do not touch the motor,
pipes, or water until the unit is unplugged or electrically
disconnected.
•
If the power disconnect is out of sight, lock it in the open
position and tag it to prevent unexpected application of
power.
•
If the disconnect panel is not accessible, contact the elec
-
tric company to stop service.