APPLICATION
SAFETY
CAREFULLY READ THESE SAFETY MESSAGES.
CAUTION
•
DO NOT OPERATE THIS PUMP DRY!
•
Review instructions before operating.
IMPORTANT:
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THE PUMP.
These pumps may be direct-coupled or belt driven from a suitable
power source - electric motor, gas engine, etc. They are intended
for installations where the vertical distance from the pump to water
surface does not exceed 7.5m (25 ft.) In all installations, friction
losses in the piping must be taken into consideration. Pump models
FACT-5 and FACT-6 should not be used for pumping liquid fertilizer.
Pump model FACT-8 can be used for liquid fertilizer if equipped with
the high temperature (Viton) seal.
INSTALLATION
(a)
LOCATION:
The pump should be installed in a location that
provides adequate drainage, room for servicing, and protection
from freezing. A proper foundation is necessary to maintain
the alignment between pump and power source. To reduce
friction losses and provide maximum capacities, the location of
the pump should be such that a minimum of suction piping is
required.
(b)
SUCTION PIPE:
It is recommended that only new, clean pipe
or hose be used and the size be the same as the pump suction
tapping. If the pump is installed any appreciable distance away
from the source of water supply, the suction pipe should be
increased by one size. The suction pipe must always slope
upwards from the water source to the pump to avoid air pockets
in the line. In cases where the pump has to be reprimed often, and
it is not necessary that a lot of water be delivered, it is advisable
to use a 90° or 45° elbow on the suction line. This enables the
pump to prime sooner and also prevents kinking of the hose.
In cases where a maximum volume of water is required over a
prolonged period of time, the suction line should be led almost
horizontally to the pump. Non-toxic thread compound should be
used on all pipe joints and connections should be thoroughly
tightened. A foot valve should be connected to the bottom end
of the suction pipe and must be submerged at all times.
PERFORMANCE
MODEL
RPM
HP
TOTAL HEAD IN FEET
10
20
30
40
50
60
80
100
120
140
CAPACITY IN GPM
FACT-5
3450
1-1/2
66
65
62
58
53
38
18
2250
1/3
42
21
FACT-6
3450
2-1/2
90
88
85
80
66
47
17
1750
1/2
50
37
11
FACT-8
3450
5
170
168
164
155
135
122
88
55
1750
1
93
78
59
Complete pressure and fl ow data is available in the Product Specifi cation Sheets and Performance Curve section.
FACT SERIES END SUCTION CENTRIFUGAL
PUMP (FOR BELT OR COUPLING DRIVE)
OWNER'S MANUAL
PUMP
WELL CASING
SUCTION LINE
FOOT VALVE
PRIMING FITTING
POWER
SOURCE
DRAIN
PLUG
DISCHARGE PIPE
Fig. 1
Содержание FACT Series
Страница 3: ...3 Fig 2 FACT 5 and FACT 6 Fig 3 FACT 8...
Страница 8: ...8 9255 Coverdale Road Fort Wayne IN 46809 Tel 260 824 2900 Fax 260 824 2909 www franklinwater com...
Страница 11: ...11 Fig 2 FACT 5 et FACT 6 Fig 3 FACT 8...
Страница 16: ...16 9255 Coverdale Road Fort Wayne IN 46809 Tel 260 824 2900 Fax 260 824 2909 www franklinwater com...