DRIVE CONFIGURATION
Motor Type Selection
24
DRIVE CONFIGURATION
Motor Type Selection
Franklin Electric 2-Wire Submersible Motor Series (DIP SW1 – Positions 1–7)
When using a Franklin Electric submersible motor, SW1 – Positions 6 and 7 must be in the
DOWN
position.
Select a single DIP switch from SW1 that corresponds with the motor/pump hp being used. The correspond
-
ing hp values are printed above the SW1 diagram on the shield.
Selecting none or more than one switch will result in an Invalid Configuration fault.
Submersible PSC Pumps (DIP SW1 – Position 6)
When using a submersible PSC style motor, SW1 – Position 6 (PSC) must be in the
UP
position.
When the drive is configured to operate a submersible PSC style pump, SW1 – Positions 1-5 must be used to
set the correct
MAX AMPS
motor overload current to properly protect the motor. Refer to
(DIP SW1 – Positions 1–5)” on page 25
for more information.
Surface Pumps (DIP SW1 – Position 7)
When using a surface/centrifugal style pump, SW1 – Position 7 (CEN) must be in the
UP
position.
When the drive is configured to operate a surface style pump, SW1 – Positions 1-5 must be used to set the
correct
MAX AMPS
motor overload current to properly protect the motor. Refer to
for more information.
NOTE:
If SW1 – Position 7 (CEN) is in the
UP
position, the drive will be configured for a surface pump regard
-
less of the position of SW1 – Position 6.
Motor Voltage
Select motor voltage using SW1 – Position 8. Place switch in the
UP
position for 115 V and
DOWN
when using a
230 VAC motor.
IMPORTANT:
Drive input voltage and motor nameplate voltage MUST match. Selecting the wrong motor
voltage will result in improper system operation or faults.
Contact with hazardous voltage could result in death or serious injury.
•
Do not attempt to modify DIP switch or potentiometer settings until power has been removed and 5
minutes have passed to allow internal voltage to discharge.
•
Do not power on or use the drive with the cover removed.
Содержание 5870202003
Страница 1: ...franklinwater com SUBDRIVEUTILITY Owner s Manual ...
Страница 41: ...41 NOTES ...
Страница 42: ...42 NOTES ...
Страница 44: ...800 348 2420 franklinwater com For technical assistance please contact Form 226115120 Rev 003 10 20 ...
Страница 45: ...ESPAÑOL ES franklinwater com SUBDRIVEUTILITY Manual para propietarios ...
Страница 89: ...franklinwater com FRANÇAIS FR SUBDRIVEUTILITY Manuel du propriétaire ...
Страница 132: ...800 348 2420 franklinwater com Pour l aide technique entrez s il vous plaît en contact Form 226115120 Rév 003 10 20 ...