INSTALLATION PLANNING
Shallow Well Surface Jet Pump Application
14
Shallow Well Surface Jet Pump Application
The above drawing illustrates how a typical surface mounted jet pump system should be arranged for a con
-
stant pressure application.
1.
Well
2.
Check Valve
3.
Ball Valve
4.
Pressure Relief Valve:
Pressure relief valve must be able to pass full pump flow up to 100 PSI.
5.
Pressure Tank:
Refer to
“Minimum Pressure Tank and Supply Pipe Sizing” on page 15
6.
Pressure Gauge
7.
Pressure Sensor or Transducer:
Install in a vertical position after the pressure tank, and within 6 feet
(1.8 meters) of the tank to minimize pressure fluctuations. There should be no elbows between the tank
and sensor.
8.
SubDrive Utility VFD
9.
Power Supply from Circuit Breaker:
Single phase, 115/230 VAC +/- 10%.
10.
Power to Motor:
Single-Phase.
IMPORTANT:
If the pump is equipped with a built-in pressure switch, the power wires from the VFD must
bypass the pressure switch and connect directly to the motor.
Risk of bodily injury or property damage.
•
Pumps can develop very high pressure in some situations. Always install a pressure relief valve able
to pass full pump flow up to 100 psi.
•
Install the pressure relief valve near the pressure tank and route to a drain capable of full system flow.
Содержание 5870202003
Страница 1: ...franklinwater com SUBDRIVEUTILITY Owner s Manual ...
Страница 41: ...41 NOTES ...
Страница 42: ...42 NOTES ...
Страница 44: ...800 348 2420 franklinwater com For technical assistance please contact Form 226115120 Rev 003 10 20 ...
Страница 45: ...ESPAÑOL ES franklinwater com SUBDRIVEUTILITY Manual para propietarios ...
Страница 89: ...franklinwater com FRANÇAIS FR SUBDRIVEUTILITY Manuel du propriétaire ...
Страница 132: ...800 348 2420 franklinwater com Pour l aide technique entrez s il vous plaît en contact Form 226115120 Rév 003 10 20 ...