background image

 

WARNING:  

Use the special scraper to immediately remove any sheets of aluminum or melted plastic that may have dropped on the hob as well as any sugar 
residue or remnants of foods with high sugar contents. This will prevent the possibility of harm to the hob.  
Never use abrasive sponges or aggressive chemical detergents such as oven sprays or spot removers.  
 
 

Technical Data 

 

 
 

Type of gas 

Burner 

Injector marking 

Rated thermal 
capacity in watts 

Reduced thermal capacity in 
watts 

Rated 
consumption 

 small 0,77 

1000 

400 

95 [/h 

Natural gas 

medium 

1,01 

1750 

450 

167 I/h 

(methane) 

dual internal 

0,63 

700 

200 

67 I/h 

G20 

dual external 

1,18 

2600 

1300 

248 I/h 

20 mbar 

totale dual 

3300 

1500 

315 I/h 

 oval  1,06 

1900 

700 

181 

[/h 

 small 50  1000 

400 

73 

g/h 

Liquiefed Gas  medium 66 

1750 

450 

127 

g/h 

G30-G31 

dual internal 

37 

700 

200 

51 g/h 

30/37 mbar 

dual external 

86 

2600 

1300 

189 g/h 

 dual -  3300  1500 

240 

g/h 

 oval 70  1900 

700 

138 

g/h 

 
 
 
Overall thermal capacity: see the identification plate on the bottom of the cooktop.  
Combustion supporting air: 2 m3/h per kW of installed power - see identification plate.  
Supply voltage: 220/230 V 50 Hz  
Cleaning and maintaining the pyroceram component  
For correct maintenance it is important to quickly remove any stains and deposits from  
the baking surface, using the special scraper provided.  

Содержание POI63GAVDO

Страница 1: ...b 2 Keep the knob strongly pressed in for 3 4 seconds to permit the spark to light the gas that exits from the flametamer and to permit the thermocouple to heat up 3 Release the knob after about 3 4 s...

Страница 2: ...device takes effect approximately 30 seconds after the flame turns off Hob cleaning and maintenance All parts made of 18 10 stainless steel will remain just like new if they are cleaned with water and...

Страница 3: ...450 167 I h methane dual internal 0 63 700 200 67 I h G20 dual external 1 18 2600 1300 248 I h 20 mbar totale dual 3300 1500 315 I h oval 1 06 1900 700 181 h small 50 1000 400 73 g h Liquiefed Gas med...

Страница 4: ...pliance can be a source of danger Make sure gas distribution systems are as required before installing the appliance The gas for which the hob is designed is indicated on the label on the bottom of th...

Страница 5: ...as illustrated in figure 3 To guarantee a proper seal insert the elastomer seal provided with the appliance B Connect the hob using a solid wall flexible steel tube Here too you must insert the seal...

Страница 6: ...jectors when other gases are used 1 remove the grillplates and burners 2 remove the injectors by unscrewing them and replace them with injectors suitable for the gas being used Make sure they are mark...

Страница 7: ...indicated on the identification plate on the bottom of the hob Make sure the electrical system meter fuses switch plug and outlet are correctly sized for the current absorption rate of the hob Fit a...

Страница 8: ...HOSE FOR CONNECTING TO THE AUXILIARY BURNER 1 15 1981860 HOSE FOR CONNECTING TO THE RIGHT MEDIUM BURNER 1 16 1981861 HOSE FOR CONNECTING TO THE REAR MEDIUM BURNER 1 17 1981862 HOSE FOR CONNECTING TO T...

Страница 9: ...METAMER 2 39 1981849 FISH CAP AND BURNER FLAMETAMER 1 40 1981850 DUAL BURNER FLAMETAMER 1 41 1981851 BLACK CAST IRON CAP FOR AUXILIARY BURNER 1 42 1981852 BLACK CAST IRON CAP FOR MEDIUM BURNER 2 43 19...

Страница 10: ...10...

Страница 11: ...2005 Satin finish knob with nut and spring FOR HOB OPERA ONLY FOR GAS BURNER AVAILABLE ONLY AS OPTIONAL Satin finish knob with nut and spring FOR knob energy regulator HI LIGHT HEATIN ELEMENT AVAILABL...

Страница 12: ...12...

Страница 13: ...13...

Отзывы: