3
WARNING:
Use the special scraper to immediately remove any sheets of aluminum or melted plastic that may have dropped on the hob as well as any sugar
residue or remnants of foods with high sugar contents. This will prevent the possibility of harm to the hob.
Never use abrasive sponges or aggressive chemical detergents such as oven sprays or spot removers.
Technical Data
Type of gas
Burner
Injector marking
Rated thermal
capacity in watts
Reduced thermal capacity in
watts
Rated
consumption
small 0,77
1000
400
95 [/h
Natural gas
medium
1,01
1750
450
167 I/h
(methane)
dual internal
0,63
700
200
67 I/h
G20
dual external
1,18
2600
1300
248 I/h
20 mbar
totale dual
-
3300
1500
315 I/h
oval 1,06
1900
700
181
[/h
small 50 1000
400
73
g/h
Liquiefed Gas medium 66
1750
450
127
g/h
G30-G31
dual internal
37
700
200
51 g/h
30/37 mbar
dual external
86
2600
1300
189 g/h
dual - 3300 1500
240
g/h
oval 70 1900
700
138
g/h
Overall thermal capacity: see the identification plate on the bottom of the cooktop.
Combustion supporting air: 2 m3/h per kW of installed power - see identification plate.
Supply voltage: 220/230 V 50 Hz
Cleaning and maintaining the pyroceram component
For correct maintenance it is important to quickly remove any stains and deposits from
the baking surface, using the special scraper provided.