manualshive.com logo in svg
background image

 

 

 

 

EN 

 

3

 

READ AND SAVE THESE INSTRUCTIONS 

The Installer must leave these instructions with the homeowner. 
The homeowner must keep these instructions for future reference and for local electrical inspec-
tors’ use. 

READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD 

WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave surface units 
unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly 
on low or medium setting. Always turn hood ON when cooking at high heat or when flambéing food (i.e. 
Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé. Clean ventilating fans frequently. Grease should 
not be allowed to accumulate on fan or filter. Use proper pan size. Always use cookware appropriate for the 
size of the surface element. 

WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE 
TOP GREASE FIRE, OBSERVE THE FOLLOWING: SMOTHER FLAMES 

with a close-fitting 

lid, cookie sheet, or metal tray, then turn off the burner

BE CAREFUL TO PREVENT BURNS

.

 If 

the flames do not go out immediately

 

EVACUATE AND CALL THE FIRE DEPARTMENT. 

NEVER PICK UP A FLAMING PAN - 

You may be burned

. DO NOT USE WATER, 

including wet 

dishcloths or towels - a violent steam explosion will result. Use an extinguisher ONLY if: 1. You 
know you have a Class ABC extinguisher, and you already know how to operate it. 2. The fire is 
small and contained in the area where it started. 3. The fire department is being called. 4. You 
can fight the fire with your back to an exit

ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE 
SEALED. 

This rangehood requires at least 24" of clearance between the bottom of the rangehood and the 
cooking surface or countertop. This minimum clearance may be higher depending on local build-
ing code. Consult the cooktop or range installation instructions given by the manufacturer before 
making any cutouts. MOBILE HOME INSTALLATION. The installation of this rangehood 
must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 
3280 (formerly Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 
280). Four wire power supply must be used and the appliance wiring must be revised. See Elec-
trical Requirements. 

VENTING REQUIREMENTS 

CAUTION - To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent ex-
haust air into spaces within walls or ceilings or into attics, crawl spaces, or garages". 

Determine which venting method is best for your application. Ductwork can extend either 
through the wall or the roof. The length of the ductwork and the number of elbows should be 
kept to a minimum to provide efficient performance. The size of the ductwork should be uni-
form. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system. 
Use caulking to seal exterior wall or floor opening around the cap. 

Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air turbu-
lence that greatly reduces performance. 
Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts. 
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting 
frame must be constructed. 

WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork. 

Содержание FDF 364 I

Страница 1: ...VISION ISLAND 36 Range Hood Hotte Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien FDF 364 I...

Страница 2: ...EN 2 2 INDEX WARNINGS AND REQUIREMENTS 3 RECOMMENDATIONS AND SUGGESTIONS 6 DIMENSIONS and MAIN PARTS 7 INSTALLATION 9 USE 13 CARE 14...

Страница 3: ...NGEHOOD IS INSTALLED MUST BE SEALED This rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop This minimum clearance may be higher depe...

Страница 4: ...achusetts 02269 This appliance should be connected directly to the fused disconnect or circuit breaker through flexible armored or nonmetallic sheathed copper cable Allow some slack in the cable so th...

Страница 5: ...American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other...

Страница 6: ...s burning appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the ope...

Страница 7: ...EN 7 7 DIMENSIONS and MAIN PARTS Dimensions...

Страница 8: ...er frame 10 1 Flange 6 10a 1 Damper 15 1 Air Outlet Connection 24 2 Connection Box 25 2 Pipe clamps Ref Q ty Installation Components 11 4 Wall Plugs If supplied 12c 6 Screws 1 8 x 1 4 12e 2 Screws 1 8...

Страница 9: ...brick ceilings with wall thickness of 13 16 drill 3 8 immediately insert the Dowels 11 if supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill 1 4 For the p...

Страница 10: ...two screws pro vided with the hood Before tightening the screws completely it is possible to adjust the frame by turning it Make sure that the screws do not come out of their seats in the slotted hole...

Страница 11: ...tion 15 Connect the hood air outlet to the flange in the lower part of the junction using a rigid 6 tube not supplied 15 10 Chimney assembly Mounting the hood body Position the upper chimney section a...

Страница 12: ...ad of the power supply to the White lead of the rangehood with a twist on type wire connec tor Attach the Black lead of the power supply to the Black lead of the rangehood with a twist on type wire co...

Страница 13: ...tor Switches the extractor motor on and off at low speed Used to provide a contin uos and silent air change in the presence of light cooking vapours V2 Speed Medium speed suitable for most operating c...

Страница 14: ...ters not supplied with the rangehood are not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently with heavy us age REPLACING OF THE FIL...

Страница 15: ...FR 1 5 15 TABLE DES MATI RES AVERTISSEMENT ET CONDITIONS N CESSAIRES 16 CONSEILS ET SUGGESTIONS 19 DIMENSIONS et PRINCIPALES PI CES 20 INSTALLATION 22 UTILISATION 26 SOIN ET ENTRETIEN 27...

Страница 16: ...ontre le feu N utilisez un extincteur que si 1 Vous avez sous la main un mod le ABC et vous comment l utiliser correctement 2 Le feu est faible et peu r pandu 3 Les pompiers sont d j pr venus 4 Vous c...

Страница 17: ...diaire de c ble conducteurs de cuivre blindage m tallique flexible ou gaine non m tallique Un serre c ble de po 12 7 mm homologation UL ou CSA doit tre install chaque extr mit du c ble d alimentation...

Страница 18: ...l American Society for Heating Refrigeration and Air Condition Engineers ASHRAE ainsi que les codes municipaux Lors d op ration de d coupage et de per age dans un mur ou un plafond veiller ne pas endo...

Страница 19: ...pi ce ou est install e la hotte par exemple des appareils fonctionnant au gaz vous devez pr voir une a ration suffisante de l espace Si la cuisine en est d pourvue pratiquez une ouverture qui communi...

Страница 20: ...FR 2 0 20 DIMENSIONS et PRINCIPALES PI CES Dimensions...

Страница 21: ...b 1 Treillis inf rieur 10 1 Rosace 6 10a 1 Clapet d air 15 1 Raccord de sortie d air 24 2 Bo te connexions 25 2 Colliers de serrage R f Qt Pi ces servant l installation 11 4 Chevilles si fournies 12c...

Страница 22: ...n des goujons pour b ton utilis s Pour les plafonds en briques avec chambre air avec paisseur r sistante de 13 16 per cer 3 8 ins rer imm diatement les chevilles 11 si fournies Pour les plafonds en po...

Страница 23: ...eil Avant de serrer d finitivement les vis il est possible d effectuer des r glages en d pla ant le treillis tout en contr lant que les vis ne sortent pas du logement de l illet de r glage L installat...

Страница 24: ...te la rosace l endroit inf rieure de la jonction l aide d un tube rigide de 6 non fourni 15 10 Montage chemin e Montage du corps de la hotte Positionner la chemin e sup rieure et fixer cette derni re...

Страница 25: ...blanc de la hotte avec une cosse connecteur de fils Atta cher le fil noir du c ble d alimentation au fil noir de la hotte avec une cosse connecteur de fils Replacer le couvercle Connecter le Connecte...

Страница 26: ...he et l arr t le moteur aspiration vitesse minimale pour un rechange d air permantent particuli rement silencieux en cas de faibles va peurs de cuisson V2 Vitesse Vitesse moyenne pour la plupart des c...

Страница 27: ...l ne sont pas lava bles ni r g n rables il faut les remplacer au moins tous les 4 mois d emploi ou plus fr quemment en cas d emploi particuli rement intense Changement des filtres Retirer les filtres...

Страница 28: ...436003944_01 070717...

Отзывы: