EN
8
8
Mounting the hood body
• Before attaching the hood body, tighten the two screws
Vr
lo-
cated on the hood body mounting points.
• Hook the hood body onto the screws
12a
.
• Fully tighten the support screws
12a
.
• Adjust the screws
Vr
to level the hood body.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange
9
on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.
9
ø 120
ø 150
AIR OUTLET – RECIRCULATION VERSION
• Unfasten the 2 screws fixing the upper bracket
7.2.1
.
• Fasten the air outlet connector
15
in its place, using the 2
screws removed as above.
• Join the Connector
15
to the Hood canopy outlet using a rigid
or flexible pipe ø150 mm, selection of which is at the
discretion of the installation technician.
• Make sure that the Activated charcoal odour filter has been
fitted.