CLEANING AND MAINTENANCE
Replacing the cartridge
1. Shut off the water supply to the
faucet.
2. Turn on the faucet briefly to relieve
any pressure inside the faucet.
3. Move the faucet handle to the “OFF”
position.
4. Remove the set screw (
A1
) from the
Handle Assembly using a 2.5 mm hex key.
5. Pull the lever handle (
A
) to remove
handle from Cartridge (
C
or
D
).
6. Unscrew and remove Handle Sleeve (
B
)
from faucet body.
7. Unscrew and remove Cartridge (
C
or
D
)
from body using 17mm wrench.
8. Install new cartridge and re-assemble
in reverse order.
9. Test for leakage.
General maintenance
Clean aerator periodically for any
buildup.
Do not use harsh detergents, solvents,
chemical agents, especially CHLORINE,
or metallic sponges as these can
damage the surface finish. Clean only
with a soft sponge and soapy water.
Do not store chemicals or cleaning
agents in the immediate vicinity of the
faucet and connection hoses. Chemical
vapors could cause damage.