ZMI
_001_
2030
0204
53-A
Q
CT0073
_#SE
N
_#AQ
U
_#V
2.f
m
- 14 -
Removing the shower panel
For some maintenance tasks, the shower panel must be removed.
Caution!
Do not allow the shower panel to hang by the connecting hoses.
Water connection from above:
22.1
Close the water volume regulators.
a: closed
b: open
22.2
Trigger the fitting.
22.3
Disconnect the water supply.
22.4
Release the screws on the shower panel.
22.5
Unhook the shower panel.
22.6
Insert the side of the shower panel in the suspension rail.
Water connection from rear:
22.7
Release the screw on the shower panel.
22.8
Unhook the shower panel.
22.9
Insert the side of the shower panel in the suspension rail.
22.10
Close the water volume regulators (see
).
22.11
Trigger the fitting.
22.12
Disconnect the water supply.
23. Maintenance information for MIRANIT-S
Soap cleaners with a neutral pH-value are sufficient for cleaning and care. Apply the
cleaner with a soft, clean cloth, leave to soak briefly and then rinse with a large
volume of water.
Caution!
The following must
not
be used:
• Cleaning agents with an abrasive effect
• Cleaning sponges / cleaning cloths with an abrasive effect
• Steel wool or other hard objects
• Solvents
☞
Important!
Possible minor damage to the surface, e.g. small scratches, can be directly polished
out. A repair kit is available for larger damaged areas. The surface is polished with
Type 1000 grinding paper after application and drying of the repair material.