- 5 -
ZMI
_001_
2000
1033
85-HDTX53
8
RS_#
SEN_#
AQU_#
V
3.
fm
• The power supply should be switched off before any work is carried out.
• We reserve the right to make changes.
5. Application
A3000 open, non-contact, electronically controlled urinal flush valve, with concealed
triggering via heat ring sensor, in combination design for rear wall installation,
with possibility of external control, such as tap settings and communication via ECC
function controller. The flow time can be set in one-second steps.
6. Technical specifications
7. ID settings (11200)
Urinal / ring sensor / RPE-MV
FUNCTION:
Flush approx. 25 s after start of use. Post flushing 1 sec. after approx. 36 s (to fill the
siphon).
SENSORS:
S2: Channel 1 / ring sensor
ACTUATORS:
A1: Channel 1 / solenoid valve / RPE
Minimum flow pressure:
1.0 bar
Recommended flow pressure:
1-5 bar
Maximum operating pressure:
10 bar
Calculated flow rate:
0.3 l/s
Flushing flow:
0.3-0.7 l/s
Flush water volumes
2–4 l adjustable
Operating voltage:
24 VDC
Power consumption:
7 W
Protection class:
Electronics IP 68, solenoid valve IP 40