RS_#
SEN_#
AQU_#
V
3.
fm
- 8 -
Caution!
Note the polarity.
The same wire colour must be in the same wire guide for both union nuts.
☞
When tightening the union nut, the electrical contact and tension relief are created
automatically.
Special seals act as protection from dust and water.
10.6
Connect the cables between the electronics module, solenoid valve cartridge,
and sensor.
A: Solenoid valve cartridge
B: Actuator 2 (optional)
C:0-10 V analogue output
D:Cold water temperature sensor (optional)
E: Hot-water temperature sensor (optional)
F: Sensor connection 2/3(optional)
G: Sensor
H:Electrical T-distributor system cable (power)
K: Electronic module
10.7
Use a hexagonal wrench to close the water volume regulator.
h: closed
i: open
10.8
Unscrew the locking screw (k) on the water volume regulator.
10.9
Insert the filter (l).
☞
Important!
Note the installation position of the filter.
10.10
Open the water quantity regulator.
11. Function
☞
The temperature of the liquid placed in the urinal must be higher than the ambient
temperature.
11.1
Use the urinal.
• After approx. 25 seconds, the urinal is flushed for 8 seconds.
• After another second, the urinal is flushed again for 0.5 seconds. This ensures
that the odour seal is filled.
☞
An automatic flushing function after 24 hours of non-use has been factory-set.
11.2
You can set the flow time and automatic flush using the system software.