Application
PROTRONIC-C mains-independent, opto-electronically-controlled washbasin mixer
DN 15 with theft-proof aerator with integrated flow rate regulator, with 6 Volt battery.
FAR Order No. 5180 10 24
– For connection to hot and cold water
– with temperature-selector lever
FAR Order No. 5181 10 24
– For connection to pre-mixed warm or cold water supply
FAR Order No. 5182 10 24
– For connection to hot and cold water
– with concealed mixing facility
6.
Technical Specifications
7.
Scope of Delivery
Minimum flow pressure:
1.0 bar
Recommended flow pressure:
1–5 bar
Maximum operating pressure:
10 bar
Calculation flow rate:
TW 0.07 l/s
TWW 0.07 l/s
Volumetric flow:
0.10 l/s for 3 bar flow pressure
Voltage supply:
6 V lithium battery (CRP2)
Type of protection:
IP 67
Quantity
Description
1
PROTRONIC-C pillar tap
with non-return valves and filters
1
Cleaning clip
1
6 V lithium battery
1
Fixing set
1
Installation and Operating Instructions