- 7 -
ZMI
_001_
2000
1033
80-CMPX
538
R
S
_#SE
N
_#AQ
U
_#V
3.f
m
10.10
Install the line connections between the electronic module, the solenoid valve and
the sensor.
A: Solenoid valve cartridge (actuator 1).
B: Solenoid valve cartridge (actuator 2, optional)
C:0-10 V analogue output
D:Cold water temperature sensor (optional)
E: Hot-water temperature sensor (optional)
F: Sensor (sensor input 2/3)
G:Sensor (sensor input 1)
H:Electrical T-distributor system cable (power)
K: Electronic module
10.11
Use an Allen key to open/close the water volume regulator.
a: closed
b: open
10.12
Unscrew the screw plugs (a) on the water volume regulator.
10.13
Replace the grit filters (b).
☞
Important!
Be careful to insert the grit filters the right way round.
10.14
Open the flow volume regulator.
10.15
10.16
11. Function
☞
The temperature of the liquid delivered into the urinal must be higher than the
ambient temperature.
11.1
Using the Urinal.
• After approx. 25 seconds the urinal is flushed for 8 seconds.
• After a further second the urinal is flushed again for 0.5 seconds. This ensures
that the odour trap is filled properly.
☞
Forced flushing has been factory set to take place after 24 H of disuse.
11.2
Flow duration and forced flushing can be set via the system cable.