background image

09/17 | 

Franke 036865-002

4

DRINKING FOUNTAIN ROUGH IN

 For all universal split level KEP( )ACSL series

RIGHT SIDE LOW

AFTER CONVERSION

THIRD ANGLE PROJECTION

AND

DIMENSIONAL DRAWING

WATER

FOUNTAIN

DRAIN TUBE

SHORT LEG

OPTIONAL GLASSFILLER

LOCATION

WATER

COOLER

35 1/4 [895]

*18 5/8 

[473]

5/16 [8]  HANGER MOUNTING

 

HOLE, 4 PLCS.

1/4 [6]  HANGER MOUNTING

 

HOLE, 2 PLCS.

1 1/4 IPS WASTE OPTIMUM

LOCATION STUB OUT 1[25]

KEPF8ACSL(EE), KEPVF8ACSL

FILTER WITH FLEXIBLE TUBING

*35 5/16

[897]

*24 1/16

[611]

*23

[584]

2 1/4 [57]

2 PLCS.

14 1/8 [359]

2 PLCS.

25/32 [20]

2 PLCS.

7 23/32 [196]

2 PLCS.

2

[51]

17 5/8 [448]

15 7/16 [392]

2 PLCS.

ELECTRICAL OUTLET 

OPTIMUM LOCATION

3/8 WATER SUPPLY OPTIMUM

LOCATION STUB OUT 1[25]

*16 1/2

[419]

7 [178]

2 PLCS.

1/2 [13]

5 1/4 [133]

1 [25]

2 PLCS.

1 1/2 [38]

2 PLCS.

*18 1/16

[459]

*21 1/4

[540]

*33 [838]

ORIFICE

*29 5/16

[744]

*27

[686]

*21 1/4

[540]

*13 9/32

[337]

7 1/16

[179]

6 7/32

[158]

1 3/4

[44]

1 1/4 O.D.

TAILPIECE

3/8 O.D.

WATER INLET

WITH STRAINER

8 1/4

[209]

*38 3/16

[970]

18 29/32

[480]

6

[152]

*37 1/32

[941]

1/2 [13]

2 PLCS.

3 5/16 [84]

12 3/4 [324]

2 PLCS.

6 3/8

[162]

2 PLCS.

AIR

FLOW

ELECTRONIC EYE MODELS ONLY

1/4 [8] MOUNTING

HOLES, 8 PLCS.

PUSH PAD

WATER COOLER 

AND FOUNTAIN

PUSH BUTTON

KEPV8ACSL

T15 DRIVE SIZE

TORX HEAD SCREWS

  NOTES:
  1.  TRAP, STOP VALVE AND ELECTRICAL 

    OUTLET NOT FURNISHED.
  2.  ALLOW 4 INCHES [102 MM] MIN.

    PER SIDE FOR VENTILATION.
* 3.  RECOMMENDED ADULT BARRIER FREE

    HEIGHT INSTALLATION SHOWN. REDUCE

    HEIGHT BY 3 INCHES FOR INSTALLATIONS

    USED PRIMARILY BY CHILDREN AGES 12 

    AND YOUNGER. UNIT SHALL ALSO HAVE A 

    MINIMUM CLEAR FLOOR SPACE 30[760] BY 

    48[1220]. ADJUST  VERTICAL DIMENSIONS 

    AS REQ’D TO COMPLY WITH PROVINCIAL 

    AND LOCAL CODES.
  4.  ALL DIMENSIONS ARE IN INCHES.

    DIMENSIONS IN BRACKETS [  ] ARE IN 

    MILLIMETERS.

RIGHT SIDE LOW AFTER CONVERSION

ROUGH-IN

Содержание 2000102904

Страница 1: ...untain Assemble the drain per the appro priate roughing in drawing The short leg of the crossover piece will be on the water cooler side When the unit has an internal waste trap the trap should be wra...

Страница 2: ...protector which will disconnect the motor from the line in case of an overload E LUBRICATION water cooler This unit is equipped with a hermetically sealed compressor and requires no additional lubrica...

Страница 3: ...16 8 HANGER MOUNTING HOLES 4 PLCS ELECTRONIC EYE MODELS ONLY PUSH PAD WATER COOLER AND FOUNTAIN KEPV8ACSL PUSH BUTTON OPTIONAL GLASSFILLER LOCATION WATER COOLER 1 1 4 O D TAILPIECE AIR FLOW 1 1 4 IPS...

Страница 4: ...459 21 1 4 540 33 838 ORIFICE 29 5 16 744 27 686 21 1 4 540 13 9 32 337 7 1 16 179 6 7 32 158 1 3 4 44 1 1 4O D TAILPIECE 3 8O D WATER INLET WITH STRAINER 8 1 4 209 38 3 16 970 18 29 32 480 6 152 37 1...

Страница 5: ...inking Water Temperature Specifications subject to change without notice 115 VAC 10 1 PH 60 Hertz 35 1 4 W 18 5 8 D 24 29 32 H 84 lbs 8 GPH 1 4 hp 4 4 amps 134a 3 95 OZ 90 F 80 F 50 F SPECIFICATIONS C...

Страница 6: ...flat blade screwdriver into the slotted hole as shown The screwdriver will engage the stream height adjuster in the cartridge plunger Turn clockwise to increase stream height or counter clockwise to r...

Страница 7: ...control 027040 039 027040 039 Not applicable 23 Relay 036056 003 036056 003 Not applicable 24 Overload 036055 003 036055 003 Not applicable 25 Start capacitor 60 MFD 027956 008 027956 008 Not applica...

Страница 8: ...e Kindred Road Midland ON L4R 4K9 Tel 1 855 446 5663 Fax 1 866 227 3050 www franke commercial com 09 17 Franke 036865 002 WIRING DIAGRAM Single KEP __ series Split Level KEP __ series WIRING DIAGRAM D...

Страница 9: ...pi ces servant la tuyauterie d vacuation pour installation sur place sont emball es dans la fontaine Assembler la tuyauterie d vacuation selon les indications du dessin de raccordement La partie la pl...

Страница 10: ...ET DE LA FONTAINE 1 Fermer le robinet d arriv e d eau 2 R cup rer l eau de vidange dans un contenant 3 D brancher la conduite d alimentation en eau au niveau du tuyau D ARRIV E D EAU du refroidisseur...

Страница 11: ...REMPLISSAGE DE VERRE REFROIDISSEUR D EAU EMBOUT DE D E 1 PO COULEMENT D AIR VACUATION DE 1 1 4 IPS EMPLACEMENT OPTIMAL DE LA TUBULURE DE SORTIE 1 25 1 1 2 13 2 ENDROITS NOTES 1 SIPHON ROBINET D ARR T...

Страница 12: ...7 1 16 179 6 7 32 158 1 3 4 44 EMBOUT DE D E 11 4 PO ARRIV E D EAU DE D E 3 8 AVEC FILTRE 8 1 4 209 38 3 16 970 18 29 32 480 6 152 37 1 32 941 1 2 13 2 ENDROITS 3 5 16 84 12 3 4 324 2 ENDROITS 6 3 8 1...

Страница 13: ...ation Temp rature d eau boire 115 VAC 10 1 PH 60 Hertz 35 1 4 L 18 5 8 P 24 29 32 H 84 lbs 8 GPH 1 4 hp 4 4 amps 134a 3 95 OZ 90 F 80 F 50 F 115 VAC 10 1 PH 60 Hertz 17 5 8 W 18 5 8 D 18 29 32 H 59 lb...

Страница 14: ...e 1 8 po dans le trou avec fente tel qu illustr Le tournevis p n tre dans le dispositif de r glage de la hauteur du jet situ dans le plongeur de la cartouche Tourner dans le sens horaire pour augmente...

Страница 15: ...issement isol 035469 055 SP 035469 055 SP Ne pas applicable 22 R glage du refroidissement 027040 039 027040 039 Ne pas applicable 23 Relais 036056 003 036056 003 Ne pas applicable 24 Surcharge 036055...

Страница 16: ...dred Road Midland ON L4R 4K9 T l 1 855 446 5663 T l copie 1 866 227 3050 www franke commercial com 09 17 Franke 036865 002 SCH MA LECTRIQUE FONTAINE BOIRE WIRING DIAGRAM Single KEP __ series Split Lev...

Отзывы: