WARNING:

The warranty and the Underwriters’ Laboratory Listing for this machine are automatically voided if this machine is 

altered, modified, or combined with any other machine or device. Alteration or modification of this machine may cause serious flood-

ing and/or hazardous electrical shock or fire. EXCEPT AS SET FORTH HEREIN, THE MANUFACTURER MAKES NO OTHER WARRANTY, 

GUARANTEE OR AGREEMENT EXPRESSED, IMPLIED OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OR MERCHANT ABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE.

C. MAINTENANCE

The only maintenance operation required is the removal of dirt and lint from the condenser of the water cooler. Inspection should be made at 

3-month intervals. Disconnect the power supply cord, then clean the condenser with a small stiff non-wire brush when required. Observance of 

this procedure will ensure adequate air circulation through the condenser so operation is efficient and economical.

D.  OVERLOAD PROTECTION (water cooler)

The compressor motor, where used, is equipped with an automatic reset protector which will disconnect the motor from the line in case of an 

overload.

E. LUBRICATION (water cooler)

This unit is equipped with a hermetically sealed compressor and requires no additional lubrication. The fan motor on this unit seldom needs 

oiling, but if required, a few drops of SAE 10 oil should be used.

F. TO DISCONTINUE USE OF WATER COOLER AND WATER FOUNTAIN

1.  Close water shut off valve.
2.  Provide container to catch water to be drained.
3.  Disconnect the water supply line at the water cooler “WATER SUPPLY” tube. Disconnect water cooler “DRAIN/REMOTE COLD WATER” 

tube from water fountain “WATER IN” tube. Place container under water cooler “DRAIN/REMOTE COLD WATER” tube, then push and 

hold push button on the water cooler until water cooler is completely drained. Place container under water fountain “WATER IN” tube, 

then push and hold push button on the water fountain until water fountain is completely drained.

4.   Disconnect the power supply cords.
5.   Plug both water cooler “DRAIN/REMOTE COLD WATER” tube, and water fountain “WATER IN” tube.
6.   ALWAYS DRAIN ALL WATER WHEN FREEZING TEMPERATURES ARE ANTICIPATED AND BEFORE SHIPPING THE WATER COOLER.

*American With Disabilities Act

DRINKING FOUNTAIN INSTALLATION

For all universal split level KEP( )ACSL series

Содержание 2000102904

Страница 1: ...untain Assemble the drain per the appro priate roughing in drawing The short leg of the crossover piece will be on the water cooler side When the unit has an internal waste trap the trap should be wra...

Страница 2: ...protector which will disconnect the motor from the line in case of an overload E LUBRICATION water cooler This unit is equipped with a hermetically sealed compressor and requires no additional lubrica...

Страница 3: ...16 8 HANGER MOUNTING HOLES 4 PLCS ELECTRONIC EYE MODELS ONLY PUSH PAD WATER COOLER AND FOUNTAIN KEPV8ACSL PUSH BUTTON OPTIONAL GLASSFILLER LOCATION WATER COOLER 1 1 4 O D TAILPIECE AIR FLOW 1 1 4 IPS...

Страница 4: ...459 21 1 4 540 33 838 ORIFICE 29 5 16 744 27 686 21 1 4 540 13 9 32 337 7 1 16 179 6 7 32 158 1 3 4 44 1 1 4O D TAILPIECE 3 8O D WATER INLET WITH STRAINER 8 1 4 209 38 3 16 970 18 29 32 480 6 152 37 1...

Страница 5: ...inking Water Temperature Specifications subject to change without notice 115 VAC 10 1 PH 60 Hertz 35 1 4 W 18 5 8 D 24 29 32 H 84 lbs 8 GPH 1 4 hp 4 4 amps 134a 3 95 OZ 90 F 80 F 50 F SPECIFICATIONS C...

Страница 6: ...flat blade screwdriver into the slotted hole as shown The screwdriver will engage the stream height adjuster in the cartridge plunger Turn clockwise to increase stream height or counter clockwise to r...

Страница 7: ...control 027040 039 027040 039 Not applicable 23 Relay 036056 003 036056 003 Not applicable 24 Overload 036055 003 036055 003 Not applicable 25 Start capacitor 60 MFD 027956 008 027956 008 Not applica...

Страница 8: ...e Kindred Road Midland ON L4R 4K9 Tel 1 855 446 5663 Fax 1 866 227 3050 www franke commercial com 09 17 Franke 036865 002 WIRING DIAGRAM Single KEP __ series Split Level KEP __ series WIRING DIAGRAM D...

Страница 9: ...pi ces servant la tuyauterie d vacuation pour installation sur place sont emball es dans la fontaine Assembler la tuyauterie d vacuation selon les indications du dessin de raccordement La partie la pl...

Страница 10: ...ET DE LA FONTAINE 1 Fermer le robinet d arriv e d eau 2 R cup rer l eau de vidange dans un contenant 3 D brancher la conduite d alimentation en eau au niveau du tuyau D ARRIV E D EAU du refroidisseur...

Страница 11: ...REMPLISSAGE DE VERRE REFROIDISSEUR D EAU EMBOUT DE D E 1 PO COULEMENT D AIR VACUATION DE 1 1 4 IPS EMPLACEMENT OPTIMAL DE LA TUBULURE DE SORTIE 1 25 1 1 2 13 2 ENDROITS NOTES 1 SIPHON ROBINET D ARR T...

Страница 12: ...7 1 16 179 6 7 32 158 1 3 4 44 EMBOUT DE D E 11 4 PO ARRIV E D EAU DE D E 3 8 AVEC FILTRE 8 1 4 209 38 3 16 970 18 29 32 480 6 152 37 1 32 941 1 2 13 2 ENDROITS 3 5 16 84 12 3 4 324 2 ENDROITS 6 3 8 1...

Страница 13: ...ation Temp rature d eau boire 115 VAC 10 1 PH 60 Hertz 35 1 4 L 18 5 8 P 24 29 32 H 84 lbs 8 GPH 1 4 hp 4 4 amps 134a 3 95 OZ 90 F 80 F 50 F 115 VAC 10 1 PH 60 Hertz 17 5 8 W 18 5 8 D 18 29 32 H 59 lb...

Страница 14: ...e 1 8 po dans le trou avec fente tel qu illustr Le tournevis p n tre dans le dispositif de r glage de la hauteur du jet situ dans le plongeur de la cartouche Tourner dans le sens horaire pour augmente...

Страница 15: ...issement isol 035469 055 SP 035469 055 SP Ne pas applicable 22 R glage du refroidissement 027040 039 027040 039 Ne pas applicable 23 Relais 036056 003 036056 003 Ne pas applicable 24 Surcharge 036055...

Страница 16: ...dred Road Midland ON L4R 4K9 T l 1 855 446 5663 T l copie 1 866 227 3050 www franke commercial com 09 17 Franke 036865 002 SCH MA LECTRIQUE FONTAINE BOIRE WIRING DIAGRAM Single KEP __ series Split Lev...

Отзывы: