Remove the cover plate
To perform maintenance work it is necessary to remove the cover plate.
14.1
Remove the screws (a) from the bottom of the cover plate.
14.2
Remove the cover plate (b).
14.3
Close the flow volume regulators (see
).
14.4
Trigger the valve.
15. Replacing the Plastic Hose
15.1
Remove the cover plate (see
15.2
Press the ring in the arrow direction.
15.3
Pull out the plastic hose.
15.4
Apply a slight pressure to push the plastic hose inwards to the stop.
15.5
Open the water volume regulators (see
).
15.6
Mount the cover plate.
16. Fault Correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our service department!!
Fault
Cause
Remedy
Water does not flow
– Water supply interrupted
➯
Restore it
– Water flow regulator closed
➯
Open it
– Solenoid valve faulty
➯
Replace it
– Electronic module defective
➯
Replace it
Water flows conti-
nuously
– Solenoid valve dirty
➯
Clean it
– Solenoid valve faulty
➯
Replace it
Water flow too weak
– Water volume regulator not fully
opened
➯
Open it
– Supply pressure too low
➯
Check it
– Flush volume adjustment is
incorrect
➯
Adjust it
Water flow too strong
– Flush volume adjustment is
incorrect
➯
Adjust it