FRANCO srl                                                                                                                    Manual of use and maintenance AP 

 

21

model: 

AP15 - AP25

 

 

Pos. 

 

Art. 

  Description 

 

 

 

 

 

 

 

 

 

 

10 

 

11 

 

12 

 

2404001 

 

2401000 

 

2401001 

 

2404050 

 

2404060 

 

2404062 

 

2400001 

 

2404052 

 

2406000 

 

2404053 

 

7303004 

 

2402001 

 

8101006 

 

BODYWORK 

 

AP15 EXCHANGER  

 

AP25 EXCHANGER 

 

EXCHANGER FIXING KIT 

 

LOUVRES FRAME 

 

LOUVER 

 

LID 

 

LID FIXING KIT 

 

AP15 - AP25 VENTILATOR 

 

VENTILAATOR FIXING KIT 

 

CONDENSE INSERT 

 

WATER SUPPLY WASHER 

 

WATER SUPPLY STRAIGHT FITTING 

 

model: 

AP30 - AP35 - AP40 - AP50 - AP60 - AP70 - AP80 - AP 100 

 

 

Pos. 

 

Art. 

  Description 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 

 

11 

 

11 

 

12 

 

12 

 
 

 

2404002 

 

2401002 

 

2401003 

 

2401004 

 

2404051 

 

2404061 

 

2404063 

 

2400002 

 

2404052 

 

2406001 

 

2406002 

 

2406003 

 

2404054 

 

7303004 

 

2402002 

 

2402003 

 

8101003 

 

8101004 

 

BODYWORK WITH FIXING INSERTS

 

 
SAP30 - AP35 - AP40

 EXCHANGER 

 

 
AP50 - AP60 - AP70 

EXCHANGER  

 

AP80 - AP100 EXCHANGER 
 

EXCHANGER FIXING KIT

 

 

LOUVRES FRAME

 

 

LOUVER 

 

LID

 

 

LID FIXING KIT

 

 
AP30 - AP50 

VENTILATOR

 

 
AP35 - AP60 - AP80 

VENTILATOR

 

 
AP40 - AP70 – AP100

VENTILATOR

 

 

VENTILATOR FIXING KIT

 

 

CONDENSE INSERT

 

 
AP30 -AP35 - AP40 

WATER SUPPLY WASHER

 

 
AP50 -AP60 - AP70 –AP80 –AP100 

WATER SUPPLY WASHER

 

 
AP30 -AP35 - AP40 

WATER SUPPLY STRAIGHT FITTING

 

 
AP50 -AP60 - AP70 – AP80 - AP100 

WATER SUPPLY STRAIGHT FITTING

 

 

Содержание 2408000

Страница 1: ...OT AND COLD WATER AEROTHERMS TRANSLATED VERSION FROM ITALIAN TO E N G L I S H Before installing or running the unit it is obligatory to carefully read and consult this manual Manual Version 05 000 201...

Страница 2: ...arts 10 1 11 Transport and handling 11 1 12 Warranty 11 1 13 Manufacturer s identification data 11 1 14 Statements 11 1 15 Declaration of conformity 12 2 INSTALLATION 13 2 1 Before installing 13 2 2 P...

Страница 3: ...ace water or any other liquids into the device In the scenario of the device becoming wet immediately turn off the electricity by lowering the switch on the electrical panel of your system and disconn...

Страница 4: ...l must be stored in a secure environment protected from moisture and heat and near the referring device The manufacturer if requested by the User may provide additional copies of the instruction manua...

Страница 5: ...perating procedures defined by the manufacturer of the machine 1 6 Glossary and pictographs In this section we list the non common terms included in the manual The following also explains the abbrevia...

Страница 6: ...ected result or endanger the safety of the personnel involved STATE OF THE MACHINE The state of the machine includes the operating mode for example running in automatic mode maintained action control...

Страница 7: ...le to operate the machine under normal conditions to run it with the maintained action control JOG with disabled protections and enabled to any kind of operation of electrical adjustment maintenance a...

Страница 8: ...impose PROHIBITION OBLIGATION Pictograph Denomination Hazardous voltage Entanglement Dragging General danger Do not remove safety devices Prohibition of cleaning oiling greasing repairing or adjustin...

Страница 9: ...are made in PA PC and ABS the screws are stainless steel made Fasteners are in stainless steel This device must be used only for the functions for which it was intended and designed Heating Cooling wo...

Страница 10: ...tenance AP 10 1 10 Description of the parts Fig 1 3 Exchanger cover Water inlet Aerotherm body Protection grill Fan Water outlet Air louvers optional Exchanger N 4 threaded insert M8 to suspend Conden...

Страница 11: ...eed for 12 months from the date of manufacture for all failures attributed to a proven manufacturing or material defect All the parts damaged by transport improper maintenance negligence inability to...

Страница 12: ...2408060 2408061 2408070 2408071 2408080 2408081 2408090 2408091 2010 Series Registration number Year of construction AP Aerotherm Commercial denomination Heating or cooling of rooms Intended use Meet...

Страница 13: ...nd with the condense drain hole siding down Use the threaded inserts for hanging the machine holding it in the correct operating position with an appropriate fixing system avoiding vibration the dista...

Страница 14: ...ection to the piping lines of water supply inlet and outlet and drainage at the proper points Fig 1 3 All the hydraulic connections must meet the local regulation in force 3 OPERATION 3 1 Getting star...

Страница 15: ...remove the 4 screws holding the safety grill of the fan to the body of the appliance Remove the fan and replace it with a new one Tighten the screws you removed previously and check that the fan blad...

Страница 16: ...FRANCO srl Manual of use and maintenance AP 16 Fig 4 1 Fig 4 2 Fig 4 3 Fig 4 4 Fig 4 5...

Страница 17: ...97 580 64 108 AP40 26 2 5 1 865 720 430 497 580 64 108 AP50 32 5 1 1 865 720 430 497 580 64 128 AP60 32 5 1 1 865 720 430 497 580 64 128 AP70 32 5 1 1 865 720 430 497 580 64 128 AP80 39 6 42 M1 865 72...

Страница 18: ...5 5 C C T TA AI I 8 85 5 C C 7 70 0 C C 7 70 0 C C 5 55 5 C C 6 60 0 C C 4 45 5 C C 5 50 0 C C 3 35 5 C C 1 15 5 C C 1 54 1 28 1 10 0 91 1 10 0 C C 1 45 1 18 1 01 0 82 5 5 C C 1 36 1 09 0 90 0 74 0 0...

Страница 19: ...4 87 23 67 837 5 1 27 2 3 500 A AP P3 35 5 6 03 6 03 24 25 1 037 7 4 52 3 5 000 A AP P4 40 0 7 02 7 02 24 64 1 207 9 6 85 4 6 500 A AP P5 50 0 7 94 7 94 20 95 1 365 3 5 54 2 3 500 A AP P6 60 0 10 17 1...

Страница 20: ...only original spare parts Orders must be made by specifying what follows Device model Reference of the piece as indicated as follows Quantity of items to be ordered Address of the client 1 10 8 4 5 3...

Страница 21: ...AP 100 Pos Art Description 1 2 2 2 3 4 5 6 7 8 8 8 9 10 11 11 12 12 2404002 2401002 2401003 2401004 2404051 2404061 2404063 2400002 2404052 2406001 2406002 2406003 2404054 7303004 2402002 2402003 8101...

Страница 22: ...tely tightened Make sure that the electricity supply characteristics are exactly as shown in the table par 5 1 Install a differential magnetic switch upstream of the device Protect with a suitable mot...

Страница 23: ...r flow or the air flow is feeble The motor is broken Contact qualified and authorized personnel to replace the motor The outlet air isn t heated or cooled The thermal circuit is not working Check the...

Страница 24: ...RANCO S r l Headquarters and plant Via Nazionale n 80 12010 CERVASCA CUNEO Italy Tel 39 0171 611663 Fax 39 0171 612337 www francosrl com info francosrl com For further information requests or suggesti...