background image

This appliance is meant to burn wood or solid fuel safely

WARNING

Incorrectly installed, this appliance can be dangerous and possibly cause serious accidents.

We recommend that you engage the services of a professional engineer for its installation

and the regular maintenance requirements

1. Description of the unit

1.1. Package

1 package : Stove

1.2. Optional equipment

Set of 4 high legs. (black Y).

1.3. Specifications

Model . . . . . . . . . . . . . . . . .

134 05 01

Chimney draft required. . . . . . . Pa

12

Hearth dimensions

- Width . . . . . . . . . . . . . . . mm

330

- Depth . . . . . . . . . . . . . . . mm

205

- Height . . . . . . . . . . . . . . mm

240

Ash pan capacity

. . . . . . . . .

liters

3

Weight . . . . . . . . . . . . . . . . kg

75

Heated volume . . . . . . . . . . . m

3

150

Wood

- Nominal Heat Output . . . . . . . kW

5

- Efficiency classification . . . . . . %

75

- Co (13% O

2

) . . . . . . . . . . . . %

0,49

- Smoke temperature . . . . . . . . °C

287

- Fuel rate . . . . . . . . . . . . . . . . kg/h

1,8

Fuel : ANTHRACITE (smokeless fuel)

- Nominal Heat Output . . . . . . . kW

3,3

- Efficiency classification . . . . . . %

61

- Co (13% O

2

) . . . . . . . . . . . . %

0,13

- Smoke temperature . . . . . . . . °C

304

- Fuel rate .  .  .  .  .  .  . . . . . . . . kg/h

0,6

The performances indicated opposite result from tests

carried out in accordance with standard EN13240 with

logs of Ø 12 of 30 cm and a depression of 12 Pa.

1.4. Description

Wood in conformity with EN 13240

Detachable flue spigot for rear or top chimney

connection.

Front loading door fitted with large refractory glass

panel.

Adjustable air controls for controlling the burning rate.

Spin wheel for lighting.

Large ash-pan.

De-scaling lever.

1.5. Operating

principle

The “MONTFORT”

is designed for

operation with the

door closed.
Heat is mainly

diffused

by

radiation, through

the window and

body

of

the

appliance.
Combustion occurs

on the grate, with

draught

entry

through the top of

the

combustion

chamber.

Technical manual “1171”

3

“MONTFORT” - ref. 134 05 01

Description of the unit

Figure 1 - Dimensions in mm

Fuel : WOOD

Logs dimensions

- Lenght maxi . . . . . . . . . . . . cm

32

Number of logs .  .  .  .  .  .  .  .  .  .  .  .  .  .          2

Interval ol charge .  .  .  .  .  .  .  .  .  .  . mn        60

Fuel load.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . kg        0,6

Interval ol charge .  .  .  .  .  .  .  .  .  .  . mn        60

Содержание MONTFORT 134 05 01

Страница 1: ...s Spare parts Warranty certificate Document n 1171 20 02 2013 MONTFORT Wood stove EN 13240 Model 134 05 01 Output 5 kW Technical manual to be saved by the user for future reference FR EN NL IT Parc d...

Страница 2: ...ith wood p 8 Instructions for use with solid fuel p 8 Cleaning p 9 Maintenance of the Chimney p 9 Maintenance of the stove p 9 Recommendations p 9 Firebricks p 9 Trouble Shooting p 10 Spare parts p 11...

Страница 3: ...61 Co 13 O2 0 13 Smoke temperature C 304 Fuel rate kg h 0 6 The performances indicated opposite result from tests carried out in accordance with standard EN13240 with logs of 12 of 30 cm and a depress...

Страница 4: ...ise it must necessary to install a non combustible protection There must be a clearance of at least 150 mm at each side of the appliance and at the back of the appliance from a non combustible wall Th...

Страница 5: ...embers It must permit an easy sweeping 2 4 Assembly of flue collar The stove is supplied with a connection flue spigot with an inner diameter of 125 mm and an outer diameter of 139 mm 2 4 1 Smoke exit...

Страница 6: ...d wood and recommended solid fuels 2 6 Pre utilisation check Check the condition of the filler seals that the door closes correctly that the window is not damaged that the smoke passages are not obstr...

Страница 7: ...an if required Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected If necessary seek expert advice Note It is recommended to use a fireguard in th...

Страница 8: ...to the right Open the primary air inlet C1 Lay firelighters or rolled up newspapers on the grate with a reasonable quantity if necessary of dry kindling wood Place a small quantity of solid fuel on to...

Страница 9: ...of the stove The appliance must be cleaned regularly together with the connecting pipe and the flue pipe Remove all deposits from the combustion chamber and clean the grate area Cleaning of the glass...

Страница 10: ...n lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression negative pressure In houses equipped with mechanical ventilation partly open a window until the f...

Страница 11: ...ng plate A B C D E F G 01 18 259015 00 Fixing plate A B C D E F G 04 19 262612 00 Heat shield A B C D E F G 01 20 270412 00 Air control flap A B C D E F G 01 21 300118 MK Leg D 04 21 300118 MP Leg E 0...

Страница 12: ...12 Technical manual 1171 MONTFORT ref 134 05 01 Spare parts Figure 10 Stove exploded view 3 45 45...

Страница 13: ...04 EF Reducing plate A B C D E F G 02 36 327906 MK Ash pan guide D 01 36 327906 MP Ash pan guide E 01 36 327906 RH Ash pan guide F 01 36 327906 RP Ash pan guide G 01 36 327906 EF Ash pan guide A 01 36...

Страница 14: ...parts covered by the guarantee is found to be too costly vis vis the price of the appliance the decision to replace or repair the appliance will be taken by the vendor Our guarantee is for 2 two year...

Отзывы: