background image

Guarantee certificate

Legal guarantee

The specifications, dimensions and information shown

on our documents are provided for information purposes

only and under no circumstances are binding upon the

vendor.

With the aim of constantly improving our equipment, all

modifications considered as necessary by our

departments may be made without notice.

The provisions of the present guarantee certificate are

not excluding or limiting the owner of the equipment’s

rights, concerning the legal guarantee regarding faults or

hidden vices which applies in all circumstances, in the

conditions detailed in articles 1641and following of the

civil code, and in the country in which the equipment was

purchased.

Contractual guarantee

Our equipment is guaranteed against faults and hidden

vices subject to the following conditions:

1) Installation and adjustment of the device by a professional

installer.

2)

Observance of the instructions provided in our technical

3) The installation, use and maintenance of the device carried

out in conformity with the applicable standards and

legislation, and with the indications provided in the technical

This guarantee covers the replacement, in our factory, of

parts recognised as being defective from the outset by

our “Guarantee Inspection” Department. Carriage and

labour is at the user’s cost. Moreover, if the repair or

replacement of parts covered by the guarantee is found

to be too costly vis-à-vis the price of the appliance, the

decision to replace or repair the appliance will be taken

by the vendor.

Our guarantee is for 2 (two) years for all appliances, with

the exception of closed combustion fireplace and inserts

for which our guarantee is 5 (five) years excluding the

following:

2) Parts subject to wear or in contact with high temperatures

namely: soles and burner grills, bottom plates baffles, ash

pans, paintwork and surface treatments for decorative

parts. Also excluded from this guarantee are seals and

windows.

3) Any damage which may result from the use of the appliance

4) Damage occurring to parts caused by elements outside the

appliance (down draught, storm damage, damp, abnormal

5) Damage to electrical parts caused by plugging in and using

the appliance on a mains system, the voltage of which

(measured at the entrance to the appliance) is 10% above

Exclusion of liability

In the case of a product manufactured at the client’s

request, under no circumstances may we, as a

subcontractor, be considered liable vis-a-vis the client or

third parties for defects arising from the installation or a

design fault with the item in question.

N

Telephone : _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

N

Date of installation :

__ ___ / ___ ___ / ___ ___ ___ ___

Model of the appliance :

134 05 01

Color :

Y

J

L

C

I

P

E

Serial number :

___ ___ ___ ___ ___ ___

In case of claims, send a copy of this to :

BOUTIQUES DU FEU - FRANCO BELGE

    

 

  

 

      

  

  

  

Parc d’activités de la Verte Rue - Allée des Prêles - 59270 BAILLEUL - FRANCE

Содержание MONTFORT 134 05 01

Страница 1: ...s Spare parts Warranty certificate Document n 1171 20 02 2013 MONTFORT Wood stove EN 13240 Model 134 05 01 Output 5 kW Technical manual to be saved by the user for future reference FR EN NL IT Parc d...

Страница 2: ...ith wood p 8 Instructions for use with solid fuel p 8 Cleaning p 9 Maintenance of the Chimney p 9 Maintenance of the stove p 9 Recommendations p 9 Firebricks p 9 Trouble Shooting p 10 Spare parts p 11...

Страница 3: ...61 Co 13 O2 0 13 Smoke temperature C 304 Fuel rate kg h 0 6 The performances indicated opposite result from tests carried out in accordance with standard EN13240 with logs of 12 of 30 cm and a depress...

Страница 4: ...ise it must necessary to install a non combustible protection There must be a clearance of at least 150 mm at each side of the appliance and at the back of the appliance from a non combustible wall Th...

Страница 5: ...embers It must permit an easy sweeping 2 4 Assembly of flue collar The stove is supplied with a connection flue spigot with an inner diameter of 125 mm and an outer diameter of 139 mm 2 4 1 Smoke exit...

Страница 6: ...d wood and recommended solid fuels 2 6 Pre utilisation check Check the condition of the filler seals that the door closes correctly that the window is not damaged that the smoke passages are not obstr...

Страница 7: ...an if required Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected If necessary seek expert advice Note It is recommended to use a fireguard in th...

Страница 8: ...to the right Open the primary air inlet C1 Lay firelighters or rolled up newspapers on the grate with a reasonable quantity if necessary of dry kindling wood Place a small quantity of solid fuel on to...

Страница 9: ...of the stove The appliance must be cleaned regularly together with the connecting pipe and the flue pipe Remove all deposits from the combustion chamber and clean the grate area Cleaning of the glass...

Страница 10: ...n lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression negative pressure In houses equipped with mechanical ventilation partly open a window until the f...

Страница 11: ...ng plate A B C D E F G 01 18 259015 00 Fixing plate A B C D E F G 04 19 262612 00 Heat shield A B C D E F G 01 20 270412 00 Air control flap A B C D E F G 01 21 300118 MK Leg D 04 21 300118 MP Leg E 0...

Страница 12: ...12 Technical manual 1171 MONTFORT ref 134 05 01 Spare parts Figure 10 Stove exploded view 3 45 45...

Страница 13: ...04 EF Reducing plate A B C D E F G 02 36 327906 MK Ash pan guide D 01 36 327906 MP Ash pan guide E 01 36 327906 RH Ash pan guide F 01 36 327906 RP Ash pan guide G 01 36 327906 EF Ash pan guide A 01 36...

Страница 14: ...parts covered by the guarantee is found to be too costly vis vis the price of the appliance the decision to replace or repair the appliance will be taken by the vendor Our guarantee is for 2 two year...

Отзывы: