This appliance is an oil-fired stove.
WARNING
An incorrectly installed oil-fired stove can cause serious accidents. This appliance should
only be installed by competent personnel.
1. Description of the unit
1.1. Description
Flued oil stove with vaporizing burner (Norm EN1)
1.2. Optional equipment
•
Ground vat.
•
Fioul tank. Capacity : 10 litres (2,6 USgal).
•
Electrical igniter.
1.3. Specifications
Model . . . . . . . . . . . . . . . . .
174 10 44
Nominal Heat Output (NF-D 35.385)kW
8.7
. . . . . . . . . . . . . . . . . . Btu/hr
30 000
Oil consumption at : . . . . . . . . . .
- maximum speed . . . . . . . . litre/h
1.2
. . . . . . . . . . . . . . . Imp gal/hr
0.264
. . . . . . . . . . . . . . . . US gal/hr
0.317
- minimum speed . . . . . . . . litre/h
0.25
. . . . . . . . . . . . . . . Imp gal/hr
0.055
. . . . . . . . . . . . . . . . US gal/hr
0.066
Chimney draft required at : . . . . . .
- maximum speed . . . . . . . . . Pa
19
. . . . . . . . . . . . . . . . . in.w.g.
0.076
- minimum speed . . . . . . . . . . Pa
9
. . . . . . . . . . . . . . . . . in.w.g.
0.036
Weight . . . . . . . . . . . . . . . kg
90
. . . . . . . . . . . . . . . . . . . lbs
199
Flue outlet diameter (O/D) . . . . mm
120/125
. . . . . . . . . . . . . . . . . . . . in
5
USA / CANADA
- Connection to a L.VENT chim-
ney
:
Nominal heat output . . . . . . . Btu/h
22,000
. . . . . . . . . . . . . . . . . . . kW
6.5
Oil consumption at nominal speedUSgal/h
. . . . . . . . . . . . . . . . . . 0.222
. . . . . . . . . . . . . . . . . . . . l/h
0.84
Technical manual “949”
3
Normandie ref. 174 10 44
Description of the unit
Figure 1 - Dimensions in
mm
745 mm ~ 29 1/3"
Ø 120 / 127 mm ~ Ø 5"
770 mm ~ 30 1/3"
390 mm ~ 15 1/3"
600 mm - 23 2/3"