2.
Installation instructions
2.1.
Assembly of the flue collar and the
blanking plates
The flue collar and the 2 blanking plates are assembling
deliver on the stove for smoke exit at rear.
Smoke exit at rear (fig. 3) :
•
The blanking plates are fitted on the top plate from
factory, fit the flue collar (3 bolts) with fire ciment.
•
Lift the top plate (2 bolts) and remove the rear heat
shield.
For installation smoke exit on the top (fig. 4):
•
Lift the top plate (2 bolts) and remove the rear heat
shield.
•
Remove the flue baffle and the refractory bricks
(# 25, # 4 and # 5 p. 11).
•
Exchange the blanking plates with the flue collar,
ensuring that it is leaktight.
•
Replace the refractory bricks and the flue baffle.
•
Reinstall the rear covering and closed the exit position
with an iron plate.
•
Refit the top plate.
2.2.
Installation
Important : Before commencing the installation of your
new appliance it is recommended that the instructions
are read and understood.
Health and safety at work act 1974
:
The installer should comply with the Health and Safety
at Work Act 1974 and with particular reference to the
following.
Handling
:
Adequate facilities should be provided for handling the
appliance.
Glass
:
Extra care should be taken to avoid breakages.
Fire cement :
Care should be taken to avoid fire cement contacting
the skin. The material is caustic and in the event of
contact being made, wash off immediately with clean
water.
Electrical :
If electrical components are to be used in the
installation system, all installation work must be carried
out in accordance with the Regulations for the Electrical
Equipment of Buildings. Care should be taken to
conform to the installation instructions of individual
manufacturers.
Flues, combustion air supply and connection of the
appliance
Current Building Regulations and relevant Codes of
Practice must be observed.
The responsability of FRANCO-BELGE only affect the
supply of the appliance.
2.3.
Siting the stove
The hearth on which the stove is to be installed must
comply with Current Building Regulations.
A fresh air inlet must be provided in order to allow
efficient combustion and to avoid a vacuum effect being
created in the room ; air extractors and fans must not be
used in the same room or adjoining room to the
installation.
This stove is not designed to be built in, and an air
space of at least 150 mm must be left all around the
stove. Ensure that appliance and flue pipe are clear of
combustible materials.
The stove should be level. Sufficient access for
chimney sweeping and appliance cleaning must be
provided.
4
Notice de référence “316”
Lorraine MF/Alsacien - réf. 124 13 01
Installation instructions
Figure 3 - Rear flue outlet
Airtight seal
Fire ciment
Figure 4 - Top flue outlet
Airtight seal