background image

DATA_TILT_POSITION (Hex 19) 

This is a three-byte command. Following the DATA_TILT_POSITION 
command two data bytes specify the position to which the lamp must move. 
The bearing resolution is 0.1 degrees. The value is sent LSB first with the first 
byte representing the lower position command bits. The MSB (sent last) lower 
4 bits represents the remaining value. The position value is centred on 2048 
(Binary 1000 0000 0000) so a value of 2048 would make the lamp move to 
the dead ahead position. An increasing value represents tilting up with a 
resolution of 0.1 degrees. A value of 2058 would therefore represent 1 degree 
up from dead ahead (2058 = 2048 + 10 

– but resolution is 0.1 degrees so a 

value 10 = 1 degree). Values below 2048 represent tilting down so a value of 
1748 would represent an angle 30 degrees down from centre. 
 

LAMP TRANSMITTED DATA 

A given lamp after it receives its normal address (Hex 110 to Hex 138) will 
always send the following data in this specific order. The lamp must transmit 
its first data byte (pan position) within 1mS of receiving its standard address 
and the gaps between successive bytes must be less than 1mS. 
 
Lamp TX Byte 1 

– Pan position LSB 

Lamp TX Byte 2 

– Pan position MSB 

Lamp TX Byte 3 

– Tilt position LSB 

Lamp TX Byte 4 

– Tilt position MSB 

Lamp TX Byte 5 

– Lamp status 

Lamp TX Byte 6 

– CRC 

 
Each byte is described below 
 

Pan Position 

This is a 12-bit value with lamp pointing straight ahead being a value of 2048 
and the value increasing as the lamp rotates clockwise as viewed from above. 
The system has a resolution of 0.1 degrees so 90 degrees clockwise from 
centre would be a value of 2948 (2048 + 900). 

 
Tilt position 

This is a 12-bit value with lamp horizontal being a value of 2048 and the value 
increasing as the lamp beam points up. This has a resolution of 0.1 degrees. 
 

Lamp Status  

This is an 8-bit value with each bit representing a specific status aspect. The 
bit functions are listed below; - 
Bit 0 - Lamp on 
Bit 1 - Pan Limit reached 
Bit 2 - Tilt Limit reached 
Bit 3 - Lamp Recording 
Bit 4 - Lamp Playing 
Bit 5 - Lamp Overheated 
Bit 6 - Lamp moving to home 
Bit 7 - Reserved 
The bits are all true logic so if the lamp is switched on, bit 0 will be high. 

 
 

Содержание FR380

Страница 1: ...A7127 FR380RC Explorer 115 240v 650 1000w A7126 FR380RC Explorer 24v 150 250w Manufacturer s details Distributor details Manual Part Number C27735 20 3 18 Issue 1 Francis Searchlights Ltd Union Road...

Страница 2: ...ty Precautions 3 Technical Information 4 Unpacking and Installation Instructions 5 Electrical Installation 6 Operating Instructions 7 Fault Finding 8 Maintenance and Servicing 9 Wiring Diagrams Genera...

Страница 3: ...ptimum performance and service life The Francis FR range combines features proven over many years service in the most hazardous conditions in both marine and land installations In order to prolong the...

Страница 4: ...e a safe working environment Never attempt to clean a lamp whilst in use Searchlights get hot Never touch the unit when lit and always allow 15 to 20 minutes for cooling down after turning the searchl...

Страница 5: ...emperature with heater 50 C 20 without 50 C 20 without The 115v searchlight also performs to the following optical data 1000 Watt T H Supply voltage 115v Peak Beam Candlepower 1 560 000 Lux Range 1249...

Страница 6: ...being installed Installation procedures should be adhered to in order to ensure a safe working environment and reduce the risk of damage or personal injury Preparing the Mounting Position Mark out and...

Страница 7: ...uitably sized cable 3 If the searchlight is located a considerable distance from the supply provision must be made in the cable size in order to overcome the voltage drop The following table below ind...

Страница 8: ...22mm 100 ohm screened cable from the joystick panel to the junction box Supply cable to the junction box A typical installation and connection routine for the FR380RC High Voltage searchlight is as f...

Страница 9: ...y particular application The beam will move continuously through spot to flood In order to fix the beam type simply release the focus button at the desired position To return the searchlight to Factor...

Страница 10: ...his will only make the conducting surface between the pin and lampholder smaller thus causing the lamp to overheat Do not twist or bend the fused quartz bulb when fitting the lamp as mechanical stress...

Страница 11: ...ition the two pins above the holes in the lampholder Gently push the lamp into the lampholder and remove the protective sleeve Replace the light shield and front bezel assembly ensuring the safety cat...

Страница 12: ...ck Wire ER Pan Encoder Red Wire 5V EG Pan Encoder Green Wire Phase A Output EW Pan Encoder White Wire Phase B Output 0V Pan Encoder Black Pan Limit Switch Common CL Pan Clockwise Limit Switch Orange W...

Страница 13: ...FBUS Speed Control Board...

Страница 14: ...OV Supply Input T Line Terminate Connect to for terminate FBUS RS485 Data In Out FBUS RS485 Data In Out 24 24V Supply Input JOYSTICK CONNECTOR BK Joystick Black Wire Y Joystick Yellow Wire BL Joystic...

Страница 15: ...the lowest value to the right The values for each switch are listed below SPEED CONTROL CARD LAMP ADDRESS SWITCH NUMBER VALUE SWITCH 4 16 SWITCH 5 8 SWITCH 6 4 SWITCH 7 2 SWITCH 8 1 STANDARD CONTROL P...

Страница 16: ...hould be set to 0 1 and 2 Control panel panel addresses use the same system being sequential and start from zero It is essential that all lamp have a unique address with no duplication It is essential...

Страница 17: ...ranges with panels being addresses 0 15 and lamp addresses starting at 16 and going up to 56 A lamp whose address was set to 0 on the address switches will actually be address 16 and would be transmit...

Страница 18: ...ckwise Increasing the value will make the lamp move faster A value of 126 will make the lamp rotate slowly anticlockwise Decreasing the value will make the lamp move faster Transmitting values 01 then...

Страница 19: ...Hex 0F This is a single byte command which activates when the home button is pressed and held for 5 seconds Home Long Press This is used to store a new home position A lamp receiving this command wil...

Страница 20: ...st transmit its first data byte pan position within 1mS of receiving its standard address and the gaps between successive bytes must be less than 1mS Lamp TX Byte 1 Pan position LSB Lamp TX Byte 2 Pan...

Страница 21: ...comprise the lamps transmitted data as described above A detailed description of transmitting and receiving is described below TRANSMITTING TO A LAMP Basically any sending device mimics a control pane...

Страница 22: ...control card has a status LED near the centre of the card labelled STATUS This has a number of functions as detailed below SOFTWARE VERSION When power is applied to the speed control card the status L...

Страница 23: ...isabled for a period when this occurs Fault indication will remain until power is removed 6 FBUS interface over current The speed control card supplies 24VDC to the remote control panels This fault in...

Страница 24: ...ured as a DCE and has all handshake lines looped No flow control is required The connections are listed below 1 Line signal detect linked to pins 4 and 6 2 TX out 3 RX in 4 DTE linked to pins 1 and 6...

Страница 25: ...ernal interface development Note that this does not affect data checking transmitted to the external interface from the interface unit and does not affect FBUS data checking SWITCH LAMP This is one of...

Страница 26: ...s initiated by the user therefore the system will be inactive until a user transmission All data reception must start with a sync byte The sync byte is value 0xFF The next byte is the lamp address The...

Страница 27: ...comprises the top 5 bits The most significant bit bit 4 0b0000x000 determines whether the pan angle is positive clockwise of centre or negative anticlockwise of centre Bit 4 set to 1 indicates angle i...

Страница 28: ...receives this command there is a 10mS delay then the interface will switch to transmit and send 13 bytes as detailed below 1 Sync FF 2 Lamp Address with bit 7 set range 0x90 0xA8 3 Pan Position LSB Sa...

Страница 29: ...the CRC and would be sent as the last byte of the packet DATA TIMING Data packets can be sent up to 10 times per second Each packet starts with the lamp address which is the only value with bit 8 set...

Страница 30: ...mp If noticeable damage to filament is present the lamp will have failed The lamp can also be checked for continuity using a multi meter Replace lamp ensuring all precautions and instructions previous...

Страница 31: ...t glass inside and out using a proprietary glass cleaner Clean the reflector if required Check the reflector mounting gaskets If signs of corrosion or damage are evident replace as necessary Ensure th...

Страница 32: ...Description A7127 FR380RC Explorer H V General Assembly A7126 FR380RC Explorer L V General Assembly C27420 High Voltage Explorer RC Wiring Diagram C27421 Low Voltage Explorer RC Wiring Diagram C27312...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ...eather Assembly C16761 00 A V Mount C20281 00 Bellows Motor Gearbox Spares C27307 01 Pan Motor Assembly C27306 01 Tilt Motor Assembly C22380 00 Micro switch no lever C22382 00 Micro switch with lever...