5. Send CRC value, in this case Hex 116 + Hex 01 + Hex A0 = 1D7 
after radix to 8 bits = B7. 
6. This completes the transmission 

 

RECEIVING FROM A LAMP 

Lamps broadcast data sequentially. There is no need to actively request data 
to be sent, just wait for the lamps address with bit 7 set to be present on the 
bus and load the next six bytes. An example is given below; - 
 

EXAMPLE 

Obtain lamp number 2 pan position. 
 

1. Listen to the data bus and wait for value Hex 112. (Lamp addresses 
start at hex 10 so lamp 2 is value 12. Addresses always have bit 8 set 
so total value is Hex 112). 
2. Load the next six bytes from the bus. 
3. If desired check the last of the six bytes which is the CRC. 
4. Read the two bytes which will be a value centred on 2048 increasing 
for clockwise from centre and decreasing for anticlockwise. This is 
lamp number 2 current pan position. 

 

FBUS Speed Control Assembly Status LED Operation 
 

Overview 
 
The FBUS motor control card has a status LED near the centre of the card 
(labelled ‘STATUS’). This has a number of functions as detailed below. 
 
SOFTWARE VERSION 
When power is applied to the speed control card the status LED will flash 
green. The number of flashes corresponds to the software version. 
 
FBUS NORMAL OPERATION  
When the system is operating from FBUS the status LED will illuminate static 
green. When a valid FBUS data signal is received the LED will switch off 
momentarily to indicate data reception. If data is continuous the LED will flash 
green slowly. 
 
DMX NORMAL OPERATION 
When the system is operating from DMX the status indicator will flash green 
slowly when DMX data is present. If no DMX data is present the LED will be 
static green. 
 
OPERATION DURING FAULTS 
During faults normal status LED operation is overridden. The status LED will 
flash red a number times with the number of flashes corresponding to the 
specific fault. If there are multiple faults the LED will flash accordingly with a 
gap between each fault flash sequence. Fault details are provided below with 
the number of flashes indicated on the left. 
 
 

Содержание FR380

Страница 1: ...A7127 FR380RC Explorer 115 240v 650 1000w A7126 FR380RC Explorer 24v 150 250w Manufacturer s details Distributor details Manual Part Number C27735 20 3 18 Issue 1 Francis Searchlights Ltd Union Road...

Страница 2: ...ty Precautions 3 Technical Information 4 Unpacking and Installation Instructions 5 Electrical Installation 6 Operating Instructions 7 Fault Finding 8 Maintenance and Servicing 9 Wiring Diagrams Genera...

Страница 3: ...ptimum performance and service life The Francis FR range combines features proven over many years service in the most hazardous conditions in both marine and land installations In order to prolong the...

Страница 4: ...e a safe working environment Never attempt to clean a lamp whilst in use Searchlights get hot Never touch the unit when lit and always allow 15 to 20 minutes for cooling down after turning the searchl...

Страница 5: ...emperature with heater 50 C 20 without 50 C 20 without The 115v searchlight also performs to the following optical data 1000 Watt T H Supply voltage 115v Peak Beam Candlepower 1 560 000 Lux Range 1249...

Страница 6: ...being installed Installation procedures should be adhered to in order to ensure a safe working environment and reduce the risk of damage or personal injury Preparing the Mounting Position Mark out and...

Страница 7: ...uitably sized cable 3 If the searchlight is located a considerable distance from the supply provision must be made in the cable size in order to overcome the voltage drop The following table below ind...

Страница 8: ...22mm 100 ohm screened cable from the joystick panel to the junction box Supply cable to the junction box A typical installation and connection routine for the FR380RC High Voltage searchlight is as f...

Страница 9: ...y particular application The beam will move continuously through spot to flood In order to fix the beam type simply release the focus button at the desired position To return the searchlight to Factor...

Страница 10: ...his will only make the conducting surface between the pin and lampholder smaller thus causing the lamp to overheat Do not twist or bend the fused quartz bulb when fitting the lamp as mechanical stress...

Страница 11: ...ition the two pins above the holes in the lampholder Gently push the lamp into the lampholder and remove the protective sleeve Replace the light shield and front bezel assembly ensuring the safety cat...

Страница 12: ...ck Wire ER Pan Encoder Red Wire 5V EG Pan Encoder Green Wire Phase A Output EW Pan Encoder White Wire Phase B Output 0V Pan Encoder Black Pan Limit Switch Common CL Pan Clockwise Limit Switch Orange W...

Страница 13: ...FBUS Speed Control Board...

Страница 14: ...OV Supply Input T Line Terminate Connect to for terminate FBUS RS485 Data In Out FBUS RS485 Data In Out 24 24V Supply Input JOYSTICK CONNECTOR BK Joystick Black Wire Y Joystick Yellow Wire BL Joystic...

Страница 15: ...the lowest value to the right The values for each switch are listed below SPEED CONTROL CARD LAMP ADDRESS SWITCH NUMBER VALUE SWITCH 4 16 SWITCH 5 8 SWITCH 6 4 SWITCH 7 2 SWITCH 8 1 STANDARD CONTROL P...

Страница 16: ...hould be set to 0 1 and 2 Control panel panel addresses use the same system being sequential and start from zero It is essential that all lamp have a unique address with no duplication It is essential...

Страница 17: ...ranges with panels being addresses 0 15 and lamp addresses starting at 16 and going up to 56 A lamp whose address was set to 0 on the address switches will actually be address 16 and would be transmit...

Страница 18: ...ckwise Increasing the value will make the lamp move faster A value of 126 will make the lamp rotate slowly anticlockwise Decreasing the value will make the lamp move faster Transmitting values 01 then...

Страница 19: ...Hex 0F This is a single byte command which activates when the home button is pressed and held for 5 seconds Home Long Press This is used to store a new home position A lamp receiving this command wil...

Страница 20: ...st transmit its first data byte pan position within 1mS of receiving its standard address and the gaps between successive bytes must be less than 1mS Lamp TX Byte 1 Pan position LSB Lamp TX Byte 2 Pan...

Страница 21: ...comprise the lamps transmitted data as described above A detailed description of transmitting and receiving is described below TRANSMITTING TO A LAMP Basically any sending device mimics a control pane...

Страница 22: ...control card has a status LED near the centre of the card labelled STATUS This has a number of functions as detailed below SOFTWARE VERSION When power is applied to the speed control card the status L...

Страница 23: ...isabled for a period when this occurs Fault indication will remain until power is removed 6 FBUS interface over current The speed control card supplies 24VDC to the remote control panels This fault in...

Страница 24: ...ured as a DCE and has all handshake lines looped No flow control is required The connections are listed below 1 Line signal detect linked to pins 4 and 6 2 TX out 3 RX in 4 DTE linked to pins 1 and 6...

Страница 25: ...ernal interface development Note that this does not affect data checking transmitted to the external interface from the interface unit and does not affect FBUS data checking SWITCH LAMP This is one of...

Страница 26: ...s initiated by the user therefore the system will be inactive until a user transmission All data reception must start with a sync byte The sync byte is value 0xFF The next byte is the lamp address The...

Страница 27: ...comprises the top 5 bits The most significant bit bit 4 0b0000x000 determines whether the pan angle is positive clockwise of centre or negative anticlockwise of centre Bit 4 set to 1 indicates angle i...

Страница 28: ...receives this command there is a 10mS delay then the interface will switch to transmit and send 13 bytes as detailed below 1 Sync FF 2 Lamp Address with bit 7 set range 0x90 0xA8 3 Pan Position LSB Sa...

Страница 29: ...the CRC and would be sent as the last byte of the packet DATA TIMING Data packets can be sent up to 10 times per second Each packet starts with the lamp address which is the only value with bit 8 set...

Страница 30: ...mp If noticeable damage to filament is present the lamp will have failed The lamp can also be checked for continuity using a multi meter Replace lamp ensuring all precautions and instructions previous...

Страница 31: ...t glass inside and out using a proprietary glass cleaner Clean the reflector if required Check the reflector mounting gaskets If signs of corrosion or damage are evident replace as necessary Ensure th...

Страница 32: ...Description A7127 FR380RC Explorer H V General Assembly A7126 FR380RC Explorer L V General Assembly C27420 High Voltage Explorer RC Wiring Diagram C27421 Low Voltage Explorer RC Wiring Diagram C27312...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ...eather Assembly C16761 00 A V Mount C20281 00 Bellows Motor Gearbox Spares C27307 01 Pan Motor Assembly C27306 01 Tilt Motor Assembly C22380 00 Micro switch no lever C22382 00 Micro switch with lever...

Отзывы: