32
Check if the electrical installation is proper to
bring the appliance in operating condition. If
electricity installation is not suitable, call an
electrician and plumber to arrange the utilities as
necessary. Manufacturer shall not be held
responsible for damages caused by operations
performed by unauthorized persons.
WARNING: It is customer’s responsibility to
prepare the location the product shall be placed on
and also to have the electrical installation prepared.
WARNING: The rules in local standards about
electrical installations shall be followed during
product installation.
WARNING: Check for any damage on the
appliance before installing it.
Do not have the product installed if it is damaged. Damaged products cause a risk for your safety.
Product is designed in accordance with the kitchen counters supplied from market.
A safe distance should be left between the product and kitchen walls and furniture. If hood/aspirator will
be installed over your appliance, obey to the recommendation of hood / aspirator manufacturer for assembly
height. (min. 65 cm)
The gap that built in hob is to be placed on the counter should be cut in line with built in hob installation
dimensions.
For installation of the product, the rules specified in local standards related to electricity should be complied.
Ventilation of room
The air needed for burning is received from room air and the gases emitted are given directly in room.
For safe operation of your product, good room ventilation is a precondition. If no window or room to
be utilized for room ventilation is available, additional ventilation should be installed. However, room
has a door opening outside, it is no needed to vent holes.
Room size
Ventilating opening
Smaller than 5 m³
min. 100 cm²
Between 5 m³ - 10 m³
min. 50 cm²
Bigger than 10 m³
no need
In basement or cellar
min. 65 cm²
11.
INSTALLATION OF BUILT IN HOB