![Fraba VITECTOR OSE-C 4024 v5 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/fraba/vitector-ose-c-4024-v5/vitector-ose-c-4024-v5_original-instructions-manual_2326070012.webp)
12
Original Instructions OSE-C 4024 v5
Version: 20190604
Original Instructions Control Unit
OSE-C 4024 v5
The entire concept of the control
system, in which the safety
component is integrated, must be
validated in accordance to the
relevant standards.
3.2
Safety Classification
The safety properties listed below are valid for the
combination of OSE-T 1100, OSE-R 1100 and
OSE-C 4024 v5. They do not include values of the
rubber profile.
Safety category
4 (EN ISO 13849-1:2008)
Performance Level
e (EN ISO 13849-1:2008)
Maximum Usage
Duration
20 years
MTTFd
1
222 years
PFHd
1
5 x 10
-8
per hour
DC
99 %
Reaction Time
< 32 ms
1
valid for B
10d
= 10
6
and N
op
< 1 per minute
3.3
Technical Data
Operating Voltage
24 V DC +20 % / -10 %
Fuse of Power Supply
1 A (slow)
Power Consumption
< 4 W
Contact Configuration
2 normally open safety
contacts
1 auxiliary contact
Contact Type
Forcibly guided relays
Fuse of Output Contact 4 A (slow)
Voltage at X1
U
max.
= 36 V
I
max.
= 50 mA
Creepage Distance
and Clearance
VDE 0160 at pollution
degree 2, overvoltage
category III/4 kV regarding
VDE 0160
Allowed Operation
Temperature
+5 °C bis +55 °C (limited
by rubber profile)
Terminal Style
IP 20 regarding to
DIN VDE 0470
Housing style
IP 40 regarding to
DIN VDE 0470
Conductor connection
2 x 2.5 mm
2
solid wire or
2 x 1.5 mm
2
stranded
wire with ferrule
Relay data
Contact material
Ag Ni
Max. switching capacity
Max. switching voltage
1 000 VA
250 V AC, 48 V DC
Max. switching current 4 A resistive
Mechanical durability
30 x 10
6
Switching cycles
B
10
values
DC13, AC15: 1 x 10
6
Содержание VITECTOR OSE-C 4024 v5