FPZ-MI-K TS-MOR-USA-15-R03
26 / 79
Abnormal vibration
G
The impeller is damaged.
Have the impeller replaced by FPZ After-Sales
Service.
G
The impeller has accumulated deposits.
Have the unit cleaned inside by FPZ After-Sales
Service.
G
Unit fixed without vibration dampers.
Have the unit secured with vibration dampers by the
Technician.
F
Rigid connection to the system
Have flexible sleeves installed between the unit and
the pipes by the Technician.
G
Faulty bearing on blower side or motor side.
Have the bearing replaced by FPZ After-Sales
Service.
Leaks
G
Faulty gaskets on the silencer.
Have the gaskets checked and, if necessary,
replaced by FPZ After-Sales Service.
G
Faulty gaskets on the cover.
Have the gaskets checked and, if necessary,
replaced by FPZ After-Sales Service.