HORIZONTAL INSTALLATION
5.2
•
Units supplied with standard set-up are ready to be installed in the horizontal position
by means of the feet.
•
The feet have holes for fixing; use all the holes and choose the appropriate type of
screw.
•
Remove the protection on the ports before checking the rotation direction and before
final connection.
•
To connect the unit to the piping, remove the flanges from the silencer housings to
make the appropriate connections using flexible sleeves, thereby avoiding rigid
connections which can cause stress and harmful vibrations.
•
Refit the flanges on the silencer housings complete with gaskets and tighten.
Check the motor rotation direction
(see par. 5.5.3 ROTATION DIRECTION)
INSTRUCTIONS FOR REPOSITIONING SILENCER HOUSINGS
5.3
•
The SCL K MOR series has been designed for maximum flexibility in positioning the silencer housings in order to allow different
installation configurations.
•
The blower is normally supplied with silencers positioned as shown in figure
A
.
•
If this arrangement has to be changed, establish the required arrangement of the silencer housings.
See the diagram provided in the first section of this manual
•
Remove and refit the housings and blind flanges according to the following diagram to obtain the desired configuration
Removing the blind flange (B)
•
Place the unit horizontal, resting the feet on a flat and stable surface.
•
Undo the screws and remove the blind flange and gasket
Removing the silencer housing (C)
•
Undo the screws.
•
Remove the silencer housing with gasket.
(C)
K05 - K06 - K07 - K08 / TS
(C)
K09 – K10 – K11 – K12 / TS
(A)
(B)
K05 - K06 / TS
(B)
K07 - K08 - K09 - K10 - K11 - K12 / TS