![FPT F4HFA615A*D001 Series Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/fpt/f4hfa615a-d001-series/f4hfa615a-d001-series_use-and-maintenance_2326030028.webp)
27
ENG
L
IS
H
Condensed water drainage from fuel tank
Proceed to the drainage / water extraction, condensation and
impurities from the fuel tank following the instructions in the
manual provided by the manufacturer of the generator.
Proceed as required by structure or location of the tank: engines
that operate in harsh environments and conditions and / or which
are supplied by drums or canisters, require more care when
cleaning the tank.
The components of the common rail system will be
rapidly damaged if the fuel contains water or
impurities.
Immediately perform the operation on the pre-filter to
drain the water present in the fuel supply circuit.
08_012_F