7. Only use filters with the following specifications:
- filtering efficiency: 95% @ 4
μ
m; 99,5% @ 6
μ
m
- maximum flow rate: 380 l/h
- operating temperature: -30 °C to 100 °C
- collapse pressure: 1000 kPa
8. Only use pre-filters with the following specifications:
- degree of filtering: 25
μ
m > 70%, 40
μ
m > 90%
- nominal flow rate: 100 l/h
- operating temperature: -25 °C to 90 °C
- collapse pressure: >3 bar
* Intervention @ frequencies expressed by hours and Temporal
(whichever occurs first).
* Intervention @ frequencies expressed by Hours and Temporal
(whichever occurs first).
REQUIREMENTS
Do not disconnect the batteries with the engine running.
Do not carry out arc welding operations in the vicinity of the
engine without first removing electrical cables.
After each maintenance operation involving disconnection of the
battery/batteries, make sure that the terminals have been properly
locked onto the poles.
Do not use battery chargers to start the engine.
Disconnect the on-board network battery/batteries when
recharging.
Do not paint the appliances, components and electrical
connectors equipping the engine.
Disconnect the battery/batteries before any electrical operations.
Contact the Manufacturer before installing electronic equipment
on board.
Extraordinary
maintenance
Frequency
Hours
Temporal
Valves/rocker arms clearance
adjustment *
3,000
-
Engine coolant replacement *
3,000
2 years
(6)
The extraordinary maintenance operations described
hereunder fall within the exclusive competence of
manufacturer’s personnel or specialised personnel
having proper working tools and adequate protection
devices. The procedure and modality for carrying out
these operations are illustrated in the FPT Technical
and Repair Manual.
Do not execute any operation which may change the
high pressure fuel pump's calibration.
The high pressure fuel pump's calibration has been
carried out in phase of engine system test based on its
final use or destination.