U32-3 FPI Direct Vent Gas Insert

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The FPI Gas Insert must be installed in  accord-
ance with these instructions. Carefully read all
the instructions in this manual first. Consult the
building authority having jurisdiction to deter-
mine the need for a permit prior to starting the
installation.

NOTE:  Failure to follow the instructions could
cause a malfunction of the heater which could
result in death, serious bodily injury, and/or
property damage.  Failure to follow these in-
structions may also void your fire insurance
and/or warranty.

FOR YOUR SAFETY

This appliance requires air for proper combus-
tion.  Always provide adequate combustion
and ventilation air.  Follow instructions and
information in CAN/CGA B149 (in Canada) or
the National Fuel Gas Code ANSI Z223.1 (in the
USA), regarding requirements for combustion
and ventilation air.

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit
must be disconnected.

Gas Input Capacity:

Natural Gas

30,000

Btu/h

Propane

30,000

Btu/h

Min. Input

Natural Gas

15,300

Btu/h

Propane

15,000

Btu/h

Fuels:  Approved for use with both natural gas,
and propane. Approved as is for use at 0' to
4,500' (0-1370m).

Electrical:  120V   A.C. system.

Circulation Fan:  Variable speed, 110 CFM.

Log Set:  Ceramic fibre, 7 per set.

Vent System:

3" co-linear aluminum flex.

The efficiency rating of the appliance is a
product thermal efficiency rating determined
under continuous operating conditions and was
determined independent of any installed sys-
tem.

INSTALLATION

GAS PRESSURE

TESTING

The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than
1/2 psig. (3.45 kPa).

INSTALLATION INTO A
SOLID FUEL BURNING

FIREPLACE OR

FACTORY BUILT

FIREPLACE

The U32-3 Gas Inserts have been tested and
approved to be vented into any masonry fire-
place or  approved solid fuel burning factory
built fireplace that will allow the insert to phys-
ically fit into the firebox. Refer to page 6 for
minimum fireplace clearances.

If the factory built fireplace* height is too low for
your Insert, you may remove the smoke baffle
plate, damper, refractory (firebricks), glass
doors, screen rails, screen mesh and log grates
from the factory built fireplace as long as these
items are saved and are reinstalled in the event
that the Insert is removed.

Smoke shelves, shields and baffles may be
removed if attached by mechanical fasteners.
If any part is removed it must not weaken the
structural integrity of the factory built fireplace.

NOTE: Any alterations made to the listed solid
fuel burning factory built fireplace may void the
listing of the fireplace.

*Check with your local inspector before com-
mencing with this installation.

BEFORE YOU START

Safe installation and operation of this appliance
requires common sense, however,  we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of the
following:

General Safety Information

1) The appliance installation must conform

with local codes or in the absence of local
codes, with CAN/CGA B149 (in Canada) or
the National Fuel Gas Code ANSI Z223.1 in
the U.S.A. This appliance should be in-
stalled by a qualified gas fitter technician
only.

2) Installation and repair should be done

by a qualified service person.

3) The  appliance should be inspected before

use and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint from
carpeting, bedding material, animal hair,
etc.  It is imperative that control compart-
ments, burners and circulating air pas-
sageways of the appliance be kept clean.

4) See general construction and assembly

instructions. This appliance may only be
installed in a vented, noncombustible fire-
place.

5) This appliance is Listed for bedroom  instal-

lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.

6) Always connect this insert to a vent system

venting to the outside of the building enve-
lope. Never vent  to another room or inside
a building.  Make sure that the vent is
properly sized and is of adequate height to
provide the proper draft.

7) Inspect the venting system annually for

blockage and any signs of deterioration.

8) Any glass removed for servicing must be

replaced prior to operating the appliance.

9) To prevent  injury, do not allow anyone who

is unfamiliar with the operation to use the
fireplace.

10) Due to high temperatures, the appliance

should be located out of high traffic areas
and away from furniture and draperies.
Children and adults should be alerted to the
hazards of high surface temperatures,
especially the fireplace glass and gold trims,
and should stay away to avoid burns or
clothing ignition. Young children should be
carefully  supervised when they are in the
same room as the appliance. Clothing or
other flammable material should not be placed
on or near the appliance.

INSTALLATION

CHECKLIST

Before installing vent system ensure that the
damper plate is open and secure to prevent the
damper plate from falling down and crushing
the liner.

The FPI Gas Insert is installed as listed below.

Emissions from burning  wood or gas could
contain chemicals known to the State of
California to  cause cancer, birth defects or
other reproductive harm.

Содержание U32-LP3

Страница 1: ...Installation and service must be performed by an authorized installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any...

Страница 2: ...Home Listed appliance comes factory equipped with a means to secure the unit INFORMATIONFORMOBILE MANUFACTUREDHOMESAFTERFIRSTSALE This FPI product has been tested and listed by Warnock Hersey as a Di...

Страница 3: ...arts List 27 Warranty Warranty 35 UnitDimensions 2 SafetyLabel 4 Installation For Your Safety 5 Specifications 5 Gas Pressure Testing 5 Installation into a Solid Fuel Burning Fireplace or Factory Buil...

Страница 4: ...ned NOTE FPI units are constantly being im proved Check the label on the unit and if there is a difference the label on the unit is the correct one For the State of Massachusetts installation and repa...

Страница 5: ...the factory built fireplace NOTE Any alterations made to the listed solid fuel burning factory built fireplace may void the listing of the fireplace Check with your local inspector before com mencing...

Страница 6: ...pages 11 and 12 13 Install both louvers flush or bay See pages 11 and 12 14 Install optional remote control or wall ther mostat pages 20 15 Final check Before leaving this unit with the customer the i...

Страница 7: ...le liner as straight as possible avoid unnecessary bending The Air Intake pipe must be attached to the inlet air collar of the termination cap Part Description 948 305 3 Flex 35 ft 946 529 Co linear D...

Страница 8: ...k tabs enough so that you can slide the brick tabs on to the screws easily but that the tabs are secure For the location of the side brick tab screws see diagram 1 5 Remove the brick tabs and slide th...

Страница 9: ...ft Log C 02 56 on the two pins as shown F 02 48 B 02 45 E 0 2 4 7 INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams If logs are broken do not use the un...

Страница 10: ...res by taking the black and red wires with the male ends in the grey harness and connect them with the wire connectors from the fan speed control 6 Connect the ON OFF switch wires by tak ing the black...

Страница 11: ...nstall the frame simply hook the top door flange onto the top of the unit and swing the door towards the unit diagram 1 Be careful that the glass gasket does not roll up there must be a gap between th...

Страница 12: ...sh door and glass must remain on the unit Hook the top of the bay door over the flush door flange and swing the bottom against the bottom flange of the flush door Press down on the Bay Bottom bracket...

Страница 13: ...left and lift off 6 Remove the Burner Tray by removing the screws on each side of the tray Push the tray to the left and lift up 7 Remove burner orifice with 1 2 wrench and replace with the 52 orifice...

Страница 14: ...into side trim 2 Lift unit up slightly and push down on the corners of the Bottom Trim Bracket and slide under unit Unit should touch tabs on Bottom Trim Bracket Bottom Trim Bracket Push in Corners 3...

Страница 15: ...e 6 The Top Frame is held in place by friction fit if the frame needs to be adjusted bend the bracket accordingly Top Frame Hinge Screen Door 7 Install the Left and Right Side Screen Doors in the full...

Страница 16: ...t wires into the strain re lief and install into switch box assembly Ensure that the top and sides are aligned 4 Use a measuring tape to ensure that the distance between the left and right side pieces...

Страница 17: ...o lock into place Slide side filler bracket into gap between glass and fire box Side Hook Slots 12 To put on the Hampton logo peel the sticker from the back of the logo and place it centered on the bo...

Страница 18: ...ess and connect them with the wire connectors from the fan speed control Connect the ON OFF switch wires by taking the black and red wires with the female ends and connect them to the ON OFF switch Tu...

Страница 19: ...rews provided Left Side Door Pin on Door Frame Note If you find that the Left or Right Side Screen Door is lower then the other use the spacer provided to help align the Doors The spacer is to be plac...

Страница 20: ...control wires for to the 120V wires 3 Install 3 AAA alkaline batteries in transmit ter and 4 AA alkaline batteries in the receiver Install the receiver and its cover in the wall Switch the remote rec...

Страница 21: ...A C supply for operation In case of a power failure the burner switch and the optional remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower...

Страница 22: ...e pilot flame should continue to burn If the pilot does not remain lit repeat operation allowing a longer period before releasing gas control knob 7 Turn gas control knob counter clockwise to ON 8 Use...

Страница 23: ...e instructions below exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO...

Страница 24: ...155 GOLD PLATED TRIM The 24 carat gold plated finish on the trim requires little maintenance and need only be cleaned with a damp cloth DO NOT use abra sive materials or chemical cleaners as they may...

Страница 25: ...ood to the rear firebox wall and lift out 8 Remove the 10 screws holding the Access Panel in place 9 Remove the Fan Air Duct by loosening the 3 screws squeeze the sides together to remove TO REMOVE FA...

Страница 26: ...the unit temporarily and check the manifold pressure 14 Reinstallthevermiculite embers rockwool logs and brick panels as needed 15 Close the door and replace the louvers 16 Fire up the unit again and...

Страница 27: ...lack 420 923 Flush Louvers Set Black Steel 25 420 940 Bay Louvers Set Black Gold 420 938 Bay Louvers Set Black 420 942 Bay Louver Set Black Steel 422 928 Brick Panel Set Standard 422 901 Brick Panel S...

Страница 28: ...t Gas 37 904 390 Burner Orifice LP 52 936 170 Orifice Gasket 66 910 038 Pilot Assembly 3 Flame NG 910 039 Pilot Assembly 3 Flame LP 67 PilotHolder 68 W840470 Pilot Assembly Gasket 69 402 935 Log Set 4...

Страница 29: ...904 196 1 Round Magnet 910 421 Pilot On Off 3 Extension Knob SIT 910 422 Flame Hi Low 3 Extension Knob SIT 402 956 Gold Trim Bay Front 402 958 Steel Trim Bay Front 113 422 960 Bay Front Screen Not ava...

Страница 30: ...ceplate Side Left Custom 74 904 586 Speed Control Knob c w Spring Clip FACEPLATE ASSEMBLY Part Description Part Description 402 918 Complete Faceplate Set Standard Contour with Black Trim 91 Faceplate...

Страница 31: ...3 Knob Black Cast Surround 201 Cast Faceplate Right 202 Cast Faceplate Top 203 Cast Faceplate Left 205 Flush Glass Frame 194 MountingFlange 195 Hampton Logo Plate 207 402 981 Cast Grill Set Top Bottom...

Страница 32: ...______________________________________________ ______________________________________________________ _______________________________________________________________ __________________________________...

Страница 33: ...______________________________________________ ______________________________________________________ _______________________________________________________________ __________________________________...

Страница 34: ...______________________________________________ ______________________________________________________ _______________________________________________________________ __________________________________...

Страница 35: ...spected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced repl...

Страница 36: ...___ Printed in Canada FPI Hampton and energy are trademarks of FPI Fireplace Products International Ltd FPI fireplaces are designed with reliability and simplicity in mind In addition our internal Qua...

Отзывы: