PARTS LIST

1)  400-011 

Fan Opening Cover

 

400-515/P 

Fan Assembly (120 V)

2)  910-331/P 

Fan Motor (120 V)

5)  910-750 

Power Cord (120 V)

 

910-752 

Wire Harness (intermediate)

6) * 

 

Thermodisc 

cover

7) * 

 

Thermodisc 

bracket

8) 910-142 

Thermodisc-Fan 

Auto 

ON/OFF

10) 400-540 

Drafthood Assembly

11) *  

Spill Switch Bracket

12) 910-220 

Spill Switch

13) *  

Levelling Bolts 5/16 x 3 Hex Head

16) *  

Cable Tie

17) *  

Wire Holder Clip

18) *  

Strain Relief

19) *  

Grommet for Power Cord

20) 400-024 

Air Channel

21) 402-922 

Flush Louvers (Set) - Gold/Black

 

402-920 

Flush Louvers (Set) - Black

 

402-924 

Flush Louvers (Set) - Steel/Black

25) 400-992 

Bay Louvers (Set) - Gold/Black

 

400-990 

Bay Louvers (Set) - Black

 

400-993 

Bay Louvers (Set) - Steel/Black

Main Assembly

         Part #        Description 

 

 

           

 

            Part #          Description

 

402-901 

Brick Panel Set - Standard Brown

 

402-902 

Brick Panel Set - Standard Red

 

402-903 

Brick Panel Set - Herringbone Brown

33) *  

Brick Panel - Back

34) *  

Brick Panel - Left Side

35) *  

Brick Panel - Right Side

36) 400-090 

Brick Clips

78) 410-920 

Zero Clearance Ashlip

 

410-905 

Zero Clearance Kit

 

402-969 

Conversion to LP Kit

 908-785  Manual

*Not available as a replacement part.

Содержание U31-LP2

Страница 1: ...appliance Do not touch any electrical switch do not use any phone in your build ing Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot rea...

Страница 2: ...VER WILL CAUSE BURNS GLASS UNTIL COOLED ALLOW CHILDREN TO TOUCH GLASS CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPECIALLY THE FIREPLACE GLASS AND SHOULD STAYAW...

Страница 3: ...been designed to provide you with all the warmth and charm of a fireplace at the flick of a switch The models U31 NG2 and U31 LP2 of this series have been approved by Warnock Hersey for both safety an...

Страница 4: ...ON For Your Safety 6 Specifications 6 Installation into a Solid Fuel Fireplace 6 General Safety Information 6 Installation Checklist 7 Materials Required 7 Minimum Fireplace Clearances 7 Clearances to...

Страница 5: ...the fireplace re approved by the authority having jurisdiction Installer l appareil selon les codes ou r glements locaux ou en l absence de tels r glements selon les codes d installation ANSI Z223 1 N...

Страница 6: ...in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY...

Страница 7: ...is to be installed 3 Ifthefactory builtfireplacehasnogasaccess hole s provided an access hole of 1 1 2 37 5mm or less may be drilled though the lower sides or bottom of the firebox in a proper workman...

Страница 8: ...s See page 9 8 Install the log set See page 9 9 Assemble and install the faceplate and trim See page 11 10 InstalltheglassfrontandoptionalBayFront See pages 11 12 11 Install both louvers See page 12 1...

Страница 9: ...ance Move the appliance into the exact location where it is to be installed Ensure that the Insert is level 4 The installer must provide a valve with a plugged tapping accessible for test gauge conne...

Страница 10: ...ENTING Diagram 1 Diagram 2 THE APPLIANCE MUST NOT BE CONNECTEDTOACHIMNEYFLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE Thisapplianceisdesignedtoattachtoa4 diam eter type B Vent or listed gas fue...

Страница 11: ...preventabuild upofcarbonmonoxide Ifthe flue is blocked or has no draw the switch will automatically shut off the supply of gas within 5 10 minutes Tampering with the switch can result in carbon monoxi...

Страница 12: ...P Vermiculite k 946 669 Platinum Embers supplied with packaged manual Note Install Optional Brick Panels prior to installing logs 1 Carefully remove the logs from the box and unwrap them The logs are...

Страница 13: ...ss the cutout on Log A 02 43 Cutout Pin Cutout Notch 8 Position notch in Front Right Log F 02 48 on Log E 02 47 and push the bottom right edge against the bracket on the burner tray and the front edge...

Страница 14: ...nd the front edge of the rear burner Side View 11 Separate platinum embers and place on and around the embers and rockwool on the burner tray Avoid stacking platinum embers 12 Test fire to ensure prop...

Страница 15: ...n the assembled faceplate panels aligning the wire connections from the switches with the notch on the left side panel 5 Connect the fan switch wires by taking the black and red wires with the male en...

Страница 16: ...ass clips at the top corners of the glass Secure glass clips with the screws provided Do not over tighten as this could break the glass 5 Slide in the top glass trim under the spring clips 2 Position...

Страница 17: ...onal remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wires do not touch any hot surfaces and are away...

Страница 18: ...side trim 2 Lift unit up slightly and push down on the corners of the Bottom Trim Bracket and slide under unit Unit should touch tabs on Bottom Trim Bracket Bottom Trim Bracket Push in Corners 3 Compl...

Страница 19: ...Top Frame is held in place by friction fit if the frame needs to be adjusted bend the bracket accordingly Top Frame Hinge Screen Door 7 Install the Left and Right Side Screen Doors in the fully open...

Страница 20: ...switch box as sembly 8 Place the switch box assembly over the boss on the rear left side piece and secure with one screw Ensure that the top and sides are aligned 4 Use a measuring tape to ensure that...

Страница 21: ...ON Note The top louver should be placed with the curved cut out facing up 13 To put on the Hampton logo peel the sticker from the back of the logo and place it centered on the bottom left hand corner...

Страница 22: ...nnectors from the fan speed control Place clips over wires and tuck into side trim for gas connection Self adhesive wire clip ON OFF switch wires to ON OFF switch wires to Fan switch connectors Fan Sp...

Страница 23: ...ush down to secure Tug on the Sur round to ensure it is securely locked in place Backside of Sur round Shown Hooks Faceplate Slots Surround Faceplate 4 Secure the Faceplate by sliding the slots in the...

Страница 24: ...me control to adjust the flame height higher or lower 10 Close the bottom louver assembly DO NOT BURN THE APPLIANCE WITH THE GLASS ASSEMBLY REMOVED OPTIONAL WALL THERMOSTAT A wall thermostat may be in...

Страница 25: ...y or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier Release...

Страница 26: ...nce and need only be cleanedwithadampcloth DONOTuseabrasive materials or chemical cleaners as they may harm the finish and void the warranty Cleananyfingerprintsoff beforeturningthe unit on If the top...

Страница 27: ...oom temperature 2 Unplug or disconnect power source to stove 3 Remove glass front see page 11 4 Remove logs 5 Remove brick panels 6 Remove the Grate by removing the screws on each side of the grate 7...

Страница 28: ...Power Cord 20 400 024 Air Channel 21 402 922 Flush Louvers Set Gold Black 402 920 Flush Louvers Set Black 402 924 Flush Louvers Set Steel Black 25 400 992 Bay Louvers Set Gold Black 400 990 Bay Louver...

Страница 29: ...Orifice Nat Gas 37 904 593 Burner Orifice Nat Gas 40 High Altitude 904 390 Burner Orifice LP 52 904 345 Burner Orifice Nat Gas 53 High Altitude 60 402 526 Grate Assembly 62 402 512 Burner Assembly NG...

Страница 30: ...n Knob Pilot ON OFF 910 426 Extension Knob Flame HI LOW 402 956 Gold Trim Bay Front Bay Flush Front Assembly Part Description Part Description Flush Door 402 515 P Complete Flush Front 150 936 243 Doo...

Страница 31: ...d 92 Faceplate Top Standard 93 Faceplate Side Left Assy Standard 402 532 Trims Pkg Standard 94 Faceplate Trim Right Standard 95 Faceplate Trim Top Standard 96 Faceplate Trim Left Assy Standard 402 933...

Страница 32: ...31 FPI U31 2 Gas Fireplace Insert PARTS LIST...

Страница 33: ...201 Cast Faceplate Right 202 Cast Faceplate Top 203 Cast Faceplate Left 205 Flush Glass Frame 194 Mounting Flange 207 402 981 Cast Grill Set Top Bottom Not available as a replacement part Last digit o...

Страница 34: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 35: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 36: ...portation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of...

Страница 37: ...Excalibur and energy are trademarks of FPI Fireplace Products International Ltd FPI fireplaces are designed with reliability and simplic ity in mind In addition our internal Quality Assurance Team ca...

Отзывы: