background image

23

FPI U31-2 Gas Fireplace Insert

OPERATING INSTRUCTIONS

OPERATING 

INSTRUCTIONS 

Before operating this appliance, proceed 
through the following check list.

1)

  Read and understand these Instructions 

before 

 

operating this appliance.

2)

  Check to see that all wiring is correct and 

enclosed to prevent possible shock.

3)

  Check to ensure there are no gas leaks.

4)

  Make sure the glass door is in place. Never 

operate the appliance with the door glass 
removed.

5)

  Verify that all venting and the cap is unob-

structed.

6)

  Verify log placement. If the pilot cannot be 

seen when lighting the unit - the logs or the 
embers have been incorrectly positioned.

7)

  The unit should never be turned off and on 

again without a minimum of a 60 second 
wait.

8)

  When lighting the appliance, the inside of 

the glass may fog up. This will burn off after 
a few minutes of operation.

LIGHTING 

PROCEDURE

IMPORTANT:  Gas cock knob cannot be 
turned from "PILOT" to "OFF" unless it is 
partially depressed.

1)

  Open the bottom louver assembly

2)

  If the control knob is in the "OFF" position 

proceed to Step 5.

 3) 

Push in gas control knob slightly and turn 
clockwise to "OFF".  Knob cannot be turned 
from "PILOT" to "OFF" unless knob is pushed 
in slightly.  Do not force.

4)

 Wait 

fi ve minutes to allow gas, that may have 

accumulated in the main burner compart-
ment, to escape. If you do smell gas, follow 
the instructions on the front of this manual. If 
you don't smell gas continue on to the next 
step.

5)

  Turn the gas control counter clockwise to 

"PILOT".

6)

  Push in control knob all the way and hold in. 

Continually push and release the black but-
ton on spark igniter until pilot lights. Continue 
to hold the control knob in for  approximately 
one minute, then release the gas control 
knob. The pilot fl ame should continue to 
burn. If the pilot does not remain lit, repeat 
operation allowing a longer period before 
releasing gas control knob.

7)

  Turn gas control knob counter clockwise to 

"ON".

8)

  Use the rocker switch to operate main 

burner.

9)

  Rotate the variable fl ame control to adjust 

the fl ame height higher or lower.

10)

 Close the bottom louver assembly.

DO NOT BURN THE APPLIANCE 
WITH THE GLASS ASSEMBLY 
REMOVED.

OPTIONAL WALL

THERMOSTAT 

A wall thermostat may be installed if desired. 
Connect the wires as per the wiring diagrams. 
Note that the wires are  connected to the "TH" 
on the gas valve. Use table on page 14 to de-
termine the maximum wire length:

Note: Preferable if the thermostat is installed 
on an interior wall.

FPI offers an optional programmable thermostat 
but any 250-750 millivolt rated non-anticipator 
type thermostat that is CSA, ULC or UL approved 
may be used.

CAUTION

Do not connect the millivolt 

wall thermostat wires 

to the 120V wires.

OPTIONAL REMOTE 

CONTROL 

Use the FPI Remote Control Kit  approved for 
this unit. Use of other systems may void your 
warranty.

The remote control kit comes with a hand held 
transmitter, a receiver and a wall mounting 
plate.

1)

  Choose a convenient location on the wall 

to install the receiver and the receptacle 
box (protection from extreme heat is very 
important). Run wires from the fi replace to 
that location, use Thermostat Wire Table.

2)

  Connect the wires as per the wiring diagram 

above.

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

50 Ft.
32 Ft.
20 Ft.
12 Ft.

9 Ft.

Recommended Maximum Lead Length 

(Two-Wire) When Using Wall 

Thermostat (CP-2 System)

Wire Size                       Max. Length

Thermostat Wire Table

CAUTION

Do not connect the millivolt re-

mote control wires to 

the 120V wires.

3)

  Install 3 AAA alkaline batteries in transmitter 

and 4 AA alkaline batteries in  the receiver. 
Install the receiver and its cover in the wall. 
Switch the  remote receiver to "remote" 
mode. The remote control is now ready for 
operation.

FINAL CHECK

Before leaving this unit with the customer, the 
installer must ensure that the appliance is fi ring 
correctly. This includes:

1)

  Clocking the appliance to ensure the cor-

rect fi ring rate (rate noted on label) at 15 
minutes.

2)

  If required, adjusting the primary air to 

ensure that the fl ame does not carbon. 
First allow the unit to burn for 15 min. to 
stabilize.

CAUTION

Any alteration to the product that causes 
sooting or carboning that results in damage 
to the exterior facia is not the responsibility 
of the manufacturer.

Содержание U31-LP2

Страница 1: ...appliance Do not touch any electrical switch do not use any phone in your build ing Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot rea...

Страница 2: ...VER WILL CAUSE BURNS GLASS UNTIL COOLED ALLOW CHILDREN TO TOUCH GLASS CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPECIALLY THE FIREPLACE GLASS AND SHOULD STAYAW...

Страница 3: ...been designed to provide you with all the warmth and charm of a fireplace at the flick of a switch The models U31 NG2 and U31 LP2 of this series have been approved by Warnock Hersey for both safety an...

Страница 4: ...ON For Your Safety 6 Specifications 6 Installation into a Solid Fuel Fireplace 6 General Safety Information 6 Installation Checklist 7 Materials Required 7 Minimum Fireplace Clearances 7 Clearances to...

Страница 5: ...the fireplace re approved by the authority having jurisdiction Installer l appareil selon les codes ou r glements locaux ou en l absence de tels r glements selon les codes d installation ANSI Z223 1 N...

Страница 6: ...in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY...

Страница 7: ...is to be installed 3 Ifthefactory builtfireplacehasnogasaccess hole s provided an access hole of 1 1 2 37 5mm or less may be drilled though the lower sides or bottom of the firebox in a proper workman...

Страница 8: ...s See page 9 8 Install the log set See page 9 9 Assemble and install the faceplate and trim See page 11 10 InstalltheglassfrontandoptionalBayFront See pages 11 12 11 Install both louvers See page 12 1...

Страница 9: ...ance Move the appliance into the exact location where it is to be installed Ensure that the Insert is level 4 The installer must provide a valve with a plugged tapping accessible for test gauge conne...

Страница 10: ...ENTING Diagram 1 Diagram 2 THE APPLIANCE MUST NOT BE CONNECTEDTOACHIMNEYFLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE Thisapplianceisdesignedtoattachtoa4 diam eter type B Vent or listed gas fue...

Страница 11: ...preventabuild upofcarbonmonoxide Ifthe flue is blocked or has no draw the switch will automatically shut off the supply of gas within 5 10 minutes Tampering with the switch can result in carbon monoxi...

Страница 12: ...P Vermiculite k 946 669 Platinum Embers supplied with packaged manual Note Install Optional Brick Panels prior to installing logs 1 Carefully remove the logs from the box and unwrap them The logs are...

Страница 13: ...ss the cutout on Log A 02 43 Cutout Pin Cutout Notch 8 Position notch in Front Right Log F 02 48 on Log E 02 47 and push the bottom right edge against the bracket on the burner tray and the front edge...

Страница 14: ...nd the front edge of the rear burner Side View 11 Separate platinum embers and place on and around the embers and rockwool on the burner tray Avoid stacking platinum embers 12 Test fire to ensure prop...

Страница 15: ...n the assembled faceplate panels aligning the wire connections from the switches with the notch on the left side panel 5 Connect the fan switch wires by taking the black and red wires with the male en...

Страница 16: ...ass clips at the top corners of the glass Secure glass clips with the screws provided Do not over tighten as this could break the glass 5 Slide in the top glass trim under the spring clips 2 Position...

Страница 17: ...onal remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wires do not touch any hot surfaces and are away...

Страница 18: ...side trim 2 Lift unit up slightly and push down on the corners of the Bottom Trim Bracket and slide under unit Unit should touch tabs on Bottom Trim Bracket Bottom Trim Bracket Push in Corners 3 Compl...

Страница 19: ...Top Frame is held in place by friction fit if the frame needs to be adjusted bend the bracket accordingly Top Frame Hinge Screen Door 7 Install the Left and Right Side Screen Doors in the fully open...

Страница 20: ...switch box as sembly 8 Place the switch box assembly over the boss on the rear left side piece and secure with one screw Ensure that the top and sides are aligned 4 Use a measuring tape to ensure that...

Страница 21: ...ON Note The top louver should be placed with the curved cut out facing up 13 To put on the Hampton logo peel the sticker from the back of the logo and place it centered on the bottom left hand corner...

Страница 22: ...nnectors from the fan speed control Place clips over wires and tuck into side trim for gas connection Self adhesive wire clip ON OFF switch wires to ON OFF switch wires to Fan switch connectors Fan Sp...

Страница 23: ...ush down to secure Tug on the Sur round to ensure it is securely locked in place Backside of Sur round Shown Hooks Faceplate Slots Surround Faceplate 4 Secure the Faceplate by sliding the slots in the...

Страница 24: ...me control to adjust the flame height higher or lower 10 Close the bottom louver assembly DO NOT BURN THE APPLIANCE WITH THE GLASS ASSEMBLY REMOVED OPTIONAL WALL THERMOSTAT A wall thermostat may be in...

Страница 25: ...y or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier Release...

Страница 26: ...nce and need only be cleanedwithadampcloth DONOTuseabrasive materials or chemical cleaners as they may harm the finish and void the warranty Cleananyfingerprintsoff beforeturningthe unit on If the top...

Страница 27: ...oom temperature 2 Unplug or disconnect power source to stove 3 Remove glass front see page 11 4 Remove logs 5 Remove brick panels 6 Remove the Grate by removing the screws on each side of the grate 7...

Страница 28: ...Power Cord 20 400 024 Air Channel 21 402 922 Flush Louvers Set Gold Black 402 920 Flush Louvers Set Black 402 924 Flush Louvers Set Steel Black 25 400 992 Bay Louvers Set Gold Black 400 990 Bay Louver...

Страница 29: ...Orifice Nat Gas 37 904 593 Burner Orifice Nat Gas 40 High Altitude 904 390 Burner Orifice LP 52 904 345 Burner Orifice Nat Gas 53 High Altitude 60 402 526 Grate Assembly 62 402 512 Burner Assembly NG...

Страница 30: ...n Knob Pilot ON OFF 910 426 Extension Knob Flame HI LOW 402 956 Gold Trim Bay Front Bay Flush Front Assembly Part Description Part Description Flush Door 402 515 P Complete Flush Front 150 936 243 Doo...

Страница 31: ...d 92 Faceplate Top Standard 93 Faceplate Side Left Assy Standard 402 532 Trims Pkg Standard 94 Faceplate Trim Right Standard 95 Faceplate Trim Top Standard 96 Faceplate Trim Left Assy Standard 402 933...

Страница 32: ...31 FPI U31 2 Gas Fireplace Insert PARTS LIST...

Страница 33: ...201 Cast Faceplate Right 202 Cast Faceplate Top 203 Cast Faceplate Left 205 Flush Glass Frame 194 Mounting Flange 207 402 981 Cast Grill Set Top Bottom Not available as a replacement part Last digit o...

Страница 34: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 35: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 36: ...portation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of...

Страница 37: ...Excalibur and energy are trademarks of FPI Fireplace Products International Ltd FPI fireplaces are designed with reliability and simplic ity in mind In addition our internal Quality Assurance Team ca...

Отзывы: