background image

26

FPI U31-2 Gas Fireplace Insert

FAN MAINTENANCE

CAUTION: 

Label all wires prior to 

disconnection when servicing con-
trols. Wiring error can cause improper 
and dangerous operation.

Remove the 2 screws holding the 

grate in position.

Remove the 2 screws, 

push Burner Tray to the left, and lift off.

Aeration Adjustment Rod 

MAINTENANCE

If your fan requires maintenance or replacement, 
access to the fan is through the plate on the 
rear wall of the fi rebox. 

NOTE: the unit MUST 

NOT be operated without the fan access 
panel securely in place.

10)

 Unplug the black wires from the fan motor 

(from inside the stove).

11)

  Lift Fan Assembly off of the 2 pins, tip forward 

and pull through fi rebox opening.

12)

 Disconnect green wire from power cord.

Replacing fan:

Reverse above steps. Hint for pushing fan down 
onto pins - rub a bit of dish soap on the grommet 
so it will slide more easily onto the pin. Check 
to make sure the fan is seated properly on the 
pins,  this is very important-  try to move the 
fan back and forth, there should be no noise, 
if there is check that the grommets haven't 
come loose.

When replacing the Burner Tray, slide the aera-
tion adjustment rod through the opening in the 
front of the Valve Assembly.

To remove fan:

1)

  Turn the unit off and allow it to cool to room 

temperature.

2)

  Unplug or disconnect power source to 

stove.

3)

  Remove glass front (see page 11).

4)

 Remove 

logs.

5)

  Remove brick panels.

6)

  Remove the Grate by removing the screws 

on each side of the grate.

7)

  Remove the Burner Tray by removing the 

screws on each side of the tray. Push the 
tray to the left and lift up.

8)

  Remove the 11 screws holding the Access 

Panel in place.

9)

  Remove the Fan Air Duct by removing 4 

screws, 2 per side.

DOOR GLASS 

REPLACEMENT

Your FPI insert is supplied with high temperature, 
5 mm Neoceram ceramic glass that will withstand 
the highest heat that your unit will produce.  In 
the event that you break your glass by impact, 
purchase your replacement from an authorized 
FPI dealer only, and follow our step-by-step 
instructions for replacement.

WARNING: do not operate appli-
ance with the glass front removed, 
cracked or broken. Replacement 
of the glass should be done by a 
licensed or qualifi ed service per-
son.

Bay Glass Removal

1) 

Remove the door from the unit and place 
on a soft surface to prevent scratching.

2)

  Remove the nuts holding the glass retainers 

in place.

3)

  Remove the glass retainers (sides, top and 

bottom).

4)

  Replace the glass. 

The glass must have 

gasketing around it.

5)

  Reverse the previous steps, replace the 

retainers and fasten with the nuts but do not 
over tighten, as this can break the glass.

6)

  Replace door on the stove and check the 

seal. 

Flush Glass Replacement

Slide old glass out of the side frames and replace 
with new glass. 

Содержание U31-LP2

Страница 1: ...appliance Do not touch any electrical switch do not use any phone in your build ing Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot rea...

Страница 2: ...VER WILL CAUSE BURNS GLASS UNTIL COOLED ALLOW CHILDREN TO TOUCH GLASS CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPECIALLY THE FIREPLACE GLASS AND SHOULD STAYAW...

Страница 3: ...been designed to provide you with all the warmth and charm of a fireplace at the flick of a switch The models U31 NG2 and U31 LP2 of this series have been approved by Warnock Hersey for both safety an...

Страница 4: ...ON For Your Safety 6 Specifications 6 Installation into a Solid Fuel Fireplace 6 General Safety Information 6 Installation Checklist 7 Materials Required 7 Minimum Fireplace Clearances 7 Clearances to...

Страница 5: ...the fireplace re approved by the authority having jurisdiction Installer l appareil selon les codes ou r glements locaux ou en l absence de tels r glements selon les codes d installation ANSI Z223 1 N...

Страница 6: ...in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY...

Страница 7: ...is to be installed 3 Ifthefactory builtfireplacehasnogasaccess hole s provided an access hole of 1 1 2 37 5mm or less may be drilled though the lower sides or bottom of the firebox in a proper workman...

Страница 8: ...s See page 9 8 Install the log set See page 9 9 Assemble and install the faceplate and trim See page 11 10 InstalltheglassfrontandoptionalBayFront See pages 11 12 11 Install both louvers See page 12 1...

Страница 9: ...ance Move the appliance into the exact location where it is to be installed Ensure that the Insert is level 4 The installer must provide a valve with a plugged tapping accessible for test gauge conne...

Страница 10: ...ENTING Diagram 1 Diagram 2 THE APPLIANCE MUST NOT BE CONNECTEDTOACHIMNEYFLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE Thisapplianceisdesignedtoattachtoa4 diam eter type B Vent or listed gas fue...

Страница 11: ...preventabuild upofcarbonmonoxide Ifthe flue is blocked or has no draw the switch will automatically shut off the supply of gas within 5 10 minutes Tampering with the switch can result in carbon monoxi...

Страница 12: ...P Vermiculite k 946 669 Platinum Embers supplied with packaged manual Note Install Optional Brick Panels prior to installing logs 1 Carefully remove the logs from the box and unwrap them The logs are...

Страница 13: ...ss the cutout on Log A 02 43 Cutout Pin Cutout Notch 8 Position notch in Front Right Log F 02 48 on Log E 02 47 and push the bottom right edge against the bracket on the burner tray and the front edge...

Страница 14: ...nd the front edge of the rear burner Side View 11 Separate platinum embers and place on and around the embers and rockwool on the burner tray Avoid stacking platinum embers 12 Test fire to ensure prop...

Страница 15: ...n the assembled faceplate panels aligning the wire connections from the switches with the notch on the left side panel 5 Connect the fan switch wires by taking the black and red wires with the male en...

Страница 16: ...ass clips at the top corners of the glass Secure glass clips with the screws provided Do not over tighten as this could break the glass 5 Slide in the top glass trim under the spring clips 2 Position...

Страница 17: ...onal remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wires do not touch any hot surfaces and are away...

Страница 18: ...side trim 2 Lift unit up slightly and push down on the corners of the Bottom Trim Bracket and slide under unit Unit should touch tabs on Bottom Trim Bracket Bottom Trim Bracket Push in Corners 3 Compl...

Страница 19: ...Top Frame is held in place by friction fit if the frame needs to be adjusted bend the bracket accordingly Top Frame Hinge Screen Door 7 Install the Left and Right Side Screen Doors in the fully open...

Страница 20: ...switch box as sembly 8 Place the switch box assembly over the boss on the rear left side piece and secure with one screw Ensure that the top and sides are aligned 4 Use a measuring tape to ensure that...

Страница 21: ...ON Note The top louver should be placed with the curved cut out facing up 13 To put on the Hampton logo peel the sticker from the back of the logo and place it centered on the bottom left hand corner...

Страница 22: ...nnectors from the fan speed control Place clips over wires and tuck into side trim for gas connection Self adhesive wire clip ON OFF switch wires to ON OFF switch wires to Fan switch connectors Fan Sp...

Страница 23: ...ush down to secure Tug on the Sur round to ensure it is securely locked in place Backside of Sur round Shown Hooks Faceplate Slots Surround Faceplate 4 Secure the Faceplate by sliding the slots in the...

Страница 24: ...me control to adjust the flame height higher or lower 10 Close the bottom louver assembly DO NOT BURN THE APPLIANCE WITH THE GLASS ASSEMBLY REMOVED OPTIONAL WALL THERMOSTAT A wall thermostat may be in...

Страница 25: ...y or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier Release...

Страница 26: ...nce and need only be cleanedwithadampcloth DONOTuseabrasive materials or chemical cleaners as they may harm the finish and void the warranty Cleananyfingerprintsoff beforeturningthe unit on If the top...

Страница 27: ...oom temperature 2 Unplug or disconnect power source to stove 3 Remove glass front see page 11 4 Remove logs 5 Remove brick panels 6 Remove the Grate by removing the screws on each side of the grate 7...

Страница 28: ...Power Cord 20 400 024 Air Channel 21 402 922 Flush Louvers Set Gold Black 402 920 Flush Louvers Set Black 402 924 Flush Louvers Set Steel Black 25 400 992 Bay Louvers Set Gold Black 400 990 Bay Louver...

Страница 29: ...Orifice Nat Gas 37 904 593 Burner Orifice Nat Gas 40 High Altitude 904 390 Burner Orifice LP 52 904 345 Burner Orifice Nat Gas 53 High Altitude 60 402 526 Grate Assembly 62 402 512 Burner Assembly NG...

Страница 30: ...n Knob Pilot ON OFF 910 426 Extension Knob Flame HI LOW 402 956 Gold Trim Bay Front Bay Flush Front Assembly Part Description Part Description Flush Door 402 515 P Complete Flush Front 150 936 243 Doo...

Страница 31: ...d 92 Faceplate Top Standard 93 Faceplate Side Left Assy Standard 402 532 Trims Pkg Standard 94 Faceplate Trim Right Standard 95 Faceplate Trim Top Standard 96 Faceplate Trim Left Assy Standard 402 933...

Страница 32: ...31 FPI U31 2 Gas Fireplace Insert PARTS LIST...

Страница 33: ...201 Cast Faceplate Right 202 Cast Faceplate Top 203 Cast Faceplate Left 205 Flush Glass Frame 194 Mounting Flange 207 402 981 Cast Grill Set Top Bottom Not available as a replacement part Last digit o...

Страница 34: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 35: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 36: ...portation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of...

Страница 37: ...Excalibur and energy are trademarks of FPI Fireplace Products International Ltd FPI fireplaces are designed with reliability and simplic ity in mind In addition our internal Quality Assurance Team ca...

Отзывы: