background image

Regency

®

 L234 Direct Vent Gas Insert

5

REQUIREMENTS

5.08: 

Modifications to NFPA-54, Chapter 10

(2) Revise 10.8.3 by adding the following additional requirements: 

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for 
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than 
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall 
be satisfied:  

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled 
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is 
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery 
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure 
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of 
qualified licensed professionals for the installation of hard wired carbon monoxide detectors 

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon 
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. 

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of 
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon 
monoxide detector with an alarm shall be installed. 

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions 
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.  

3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The 
sign shall read, in print size no less than one-half (1/2) inch in size, 

"GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL 

OBSTRUCTIONS". 

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation 
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 
5.08(2)(a)1 through 4.  

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:  

1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by 
the Board; and  

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or 
structure used in whole or in part for residential purposes.  

(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product 
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the 
instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 

1. Detailed instructions for the installation of the venting system design or the venting system components; and 

2. A complete parts list for the venting system design or venting system.  

(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a 
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies 
"special venting systems", the following requirements shall be satisfied by the manufacturer: 

1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and  

2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and 
detailed installation instructions.  

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, 
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of 
the installation.  

MA Code - CO Detector

(for the State of Massachusetts only)

Содержание L234

Страница 1: ...allation and service must be performed by an authorized installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any elec...

Страница 2: ...vide you with all the warmth and charm of a fireplace at the flick of a switch The L234 NG and L234 LP have been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark...

Страница 3: ...g 14 SIT Valve Description 14 Conversion Kit 536 969 from NG to LP 15 Optional Brick Panel Installation 17 Screen door install removal 18 Glass door install removal 18 Contour or Contemporary Faceplat...

Страница 4: ...t and if there is a difference the label on the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Ma...

Страница 5: ...ly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECT...

Страница 6: ...6 Regency L234 Direct Vent Gas Insert DIMENSIONS...

Страница 7: ...PPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE YOUNG CHI...

Страница 8: ...himneycleanoutsmustfitproperly Refractory glass doors screen rails screen mesh and log grates can be removed from the fireplace beforeinstallingthegasfireplaceinsert Smoke shelves shields and baffles...

Страница 9: ...optional features Refer to the following sections where applicable a Brick Panels b Log Installation c Faceplate d Hearth Trim e Backing Plate f RemoteControl brickpanelsare mandatory with remote con...

Страница 10: ...non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour Unless otherwise stated the clear...

Страница 11: ...of the termination cap NOTE Simpson Duravent can only be used with 3 and 3 liners INSTALLATION WITH 3 3 LINERS Part Description 948 305 3 Flex 35 ft intake exhaust 946 529 FPI Co linear DV Vertical Te...

Страница 12: ...the 4 screws that hold the vent restrictor plate in place 2 Remove the 3 collar from the top plate by undoing the 4 screws NOTE The screws are secured from the underside of the top plate Underside of...

Страница 13: ...NOTE 1 Final gas connection should be made after unit is in place to avoid damage to the liner when pushing the unit into position 2 Mill pac may be used instead of high tempture silicone and screws...

Страница 14: ...ve is in the OFF position 2 Loosenthe IN and or OUT pressuretap s turningcounterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Lig...

Страница 15: ...INSTALLATION 1 Open the left and right side faceplate panels 2 Turn off the gas supply 3 Remove the bottom louver by pulling out 4 Remove the glass door a Pull off the left side spring hook that hold...

Страница 16: ...ig 3 17 Using the allen key as shown in Fig 4 rotate the screw clockwise until snug do not overtighten Fig 3 Fig 4 WARNING Do not overtighten the screw Recommended to grip the wrench by the short side...

Страница 17: ...ck panel by carefully placing it against the back wall of the firebox and rest it on the rear log tray Back Brick Panel Rear Log Tray 3 Slide the right side brick panel into position and secure in pla...

Страница 18: ...side down and place it into the middle opening on the top side mounting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 1 Remove the glass door 2 Hook the screen door...

Страница 19: ...ft and right side panels to show keyhole mounting 2 Open the left and right side faceplate panels of the faceplate 3 Mount the faceplate onto the unit by aligning the 4 key hole slots in the faceplate...

Страница 20: ...rom the sleeve and connect them to the wires from the unit as shown in diagram 10 9 Close the right side faceplate panel 10 Remove the remote receiver bracket from the left side of the unit by undoing...

Страница 21: ...12 and put back in place see diagram 13 NOTE Ensure connectors are tucked in behind the mounting bracket to allow the side faceplate panel to close easily Diagram 12 Diagram 13 15 Re install the remot...

Страница 22: ...soft surface to prevent scratching Backing Plate Installation Customize Backing Plate The inside of the backing plate may be cut as required using a metal cutting blade Do not cut the outside edges Th...

Страница 23: ...ight Corner Backing Plate 9 Place the right side corner backing plate over the top and right side backing plate Push in place to secure see diagram 5 Repeat for left side Completed Backing Plate Insta...

Страница 24: ...panels to show mounting of hearth trim a The Hearth Trim can be adjusted to custom fit an installation by pulling apart the top piece from the bottom piece b Cut the top of the bottom piece of the he...

Страница 25: ...y remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Fit log 2 711 into the pins on the rear log tray 2 711 3 Place log 2 714 on the base o...

Страница 26: ...g 2 713 into the pin on log 2 714 and rest the right side of the log on the burner plate pushing it against the tab 2 712 2 713 2 714 2 713 6 Place log 2 715 into the pin on log 2 712 and rest the rig...

Страница 27: ...e right side of the burner as shown 8 Fit log 2 716 into the pin on log 2 712 Right side of Burner 2 713 2 716 2 712 Also place a few embers along the burner tube next to log 2 713 Separate platinum e...

Страница 28: ...28 Regency L234 Direct Vent Gas Insert INSTALLATION Completed Log Set Installation 2 711 2 716 2 715 2 712 2 713 2 714...

Страница 29: ...surfaces and are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be p...

Страница 30: ...iring rate rate noted on label at 15 minutes 2 Ifrequired adjustingtheprimaryairtoensure that the flame does not carbon First allow the unit to burn for 15 min to stabilize 3 Check for proper draft CA...

Страница 31: ...seen when lighting the unit the logs have been incorrectly positioned 8 The unit should never be turned off and on again without a minimum of a 60 second wait LIGHTING PROCEDURE During the first few...

Страница 32: ...und when ON This sound will increase or decrease in volume depending on the speed setting of your fan speed control Burner Tray The burner tray is positioned directly under the burnertube s andlogsand...

Страница 33: ...ANCE CAUTION ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE AP...

Страница 34: ...Whileholdingthehookturn it upside down and place it into the middle opening on the top side mounting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 5 Remove the logs...

Страница 35: ...fan by sliding the fan forward and lift up and out 14 Remove the ground screw which holds the ground wire Ground Wire 15 Replace the fan NOTE Bendtheconnectorclipsdownbefore re installing the fan cov...

Страница 36: ...lace it into the middle opening on the top side mounting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 7 Disconnect the gas connection to the valve 8 Disconnect the...

Страница 37: ...ews Rear Log Tray Removed 14 Remove the 12 screws that hold the valve tray to the firebox and carefully pull out 15 Replace the valve 16 Reverse steps 14 1 11 Remove the burner by undoing the 3 screws...

Страница 38: ...el Set Standard Brown 536 902 Brick Panel Set Standard Red 9 Brick Panel Right 10 Brick Panel Left 11 Brick Panel Back 511 031 Brick Clip 12 536 523 Flue Adaptor Assembly 13 Valve Shield 14 536 091 Pi...

Страница 39: ...CEPLATE ASSEMBLY Part Description 60 536 918 Contemporary Faceplate 61 536 914 Contour Faceplate 62 910 246 Burner ON OFF Switch 63 910 330 Fan Speed Control 120 V 64 904 569 Fan Speed Control Knob 65...

Страница 40: ...Insert PARTS LIST BACKING PLATE HEARTH TRIM ASSEMBLY Part Description 536 922 Backing Plate 81 Left Side 82 Right Side 83 Top 84 Left Corner 85 Right Corner 536 940 Hearth Trim 86 Top 87 Bottom Not a...

Страница 41: ...Regency L234 Direct Vent Gas Insert 41 NOTES...

Страница 42: ...42 Regency L234 Direct Vent Gas Insert NOTES...

Страница 43: ...nsportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days...

Страница 44: ..._________________________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial...

Отзывы: