background image

Regency

®

 L234 Direct Vent Gas Insert

43

WARRANTY

Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit 
thoroughly before it leaves our facility.  FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the  original purchaser of a 
Excalibur Product. This warranty is not transferable.

The Warranty:  

Limited Lifetime

The combustion chamber, heat exchanger, burner tubes/pans, logs, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime 
Warranty for fi ve (5) years for parts and subsidized labour* and parts only thereafter.

Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for fi ve (5) years and parts only thereafter from date of purchase.

External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date 
of purchase and parts only thereafter.

Special Finishes - One year on brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant heating 
and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, 
ie. fi nger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.

Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly components, 
and gas valves are covered for two years parts and one year subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered repairs and 
continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date of replacement.

FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.

Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any 
item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Conditions:

Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent provided 
that the defective part be returned to the distributor or agent 

Transportation Prepaid,

 if requested.

Porcelain/Enamel - Absolute perfection is either guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days of 
installation. Reported damage after this time will be subject to rejection.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated 
for manufacturer defect.

The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from 
unauthorized service persons or dealers. 

At all times FPI reserves the right to inspect product in the fi eld which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, 
purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. 
ie. as products evolve, fi eld modifi cations or upgrades will not be performed.

FPI will not be liable for travel costs for service work. 

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the  terms of this warranty policy.

Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse, improper installation, negligence 
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical 
systems such as furnaces, fans, clothes dryer, etc.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your warranty 
on this product.

Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.

* Subsidy according to job scale as predetermined by FPI.

Содержание L234

Страница 1: ...allation and service must be performed by an authorized installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any elec...

Страница 2: ...vide you with all the warmth and charm of a fireplace at the flick of a switch The L234 NG and L234 LP have been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark...

Страница 3: ...g 14 SIT Valve Description 14 Conversion Kit 536 969 from NG to LP 15 Optional Brick Panel Installation 17 Screen door install removal 18 Glass door install removal 18 Contour or Contemporary Faceplat...

Страница 4: ...t and if there is a difference the label on the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Ma...

Страница 5: ...ly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECT...

Страница 6: ...6 Regency L234 Direct Vent Gas Insert DIMENSIONS...

Страница 7: ...PPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE YOUNG CHI...

Страница 8: ...himneycleanoutsmustfitproperly Refractory glass doors screen rails screen mesh and log grates can be removed from the fireplace beforeinstallingthegasfireplaceinsert Smoke shelves shields and baffles...

Страница 9: ...optional features Refer to the following sections where applicable a Brick Panels b Log Installation c Faceplate d Hearth Trim e Backing Plate f RemoteControl brickpanelsare mandatory with remote con...

Страница 10: ...non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour Unless otherwise stated the clear...

Страница 11: ...of the termination cap NOTE Simpson Duravent can only be used with 3 and 3 liners INSTALLATION WITH 3 3 LINERS Part Description 948 305 3 Flex 35 ft intake exhaust 946 529 FPI Co linear DV Vertical Te...

Страница 12: ...the 4 screws that hold the vent restrictor plate in place 2 Remove the 3 collar from the top plate by undoing the 4 screws NOTE The screws are secured from the underside of the top plate Underside of...

Страница 13: ...NOTE 1 Final gas connection should be made after unit is in place to avoid damage to the liner when pushing the unit into position 2 Mill pac may be used instead of high tempture silicone and screws...

Страница 14: ...ve is in the OFF position 2 Loosenthe IN and or OUT pressuretap s turningcounterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Lig...

Страница 15: ...INSTALLATION 1 Open the left and right side faceplate panels 2 Turn off the gas supply 3 Remove the bottom louver by pulling out 4 Remove the glass door a Pull off the left side spring hook that hold...

Страница 16: ...ig 3 17 Using the allen key as shown in Fig 4 rotate the screw clockwise until snug do not overtighten Fig 3 Fig 4 WARNING Do not overtighten the screw Recommended to grip the wrench by the short side...

Страница 17: ...ck panel by carefully placing it against the back wall of the firebox and rest it on the rear log tray Back Brick Panel Rear Log Tray 3 Slide the right side brick panel into position and secure in pla...

Страница 18: ...side down and place it into the middle opening on the top side mounting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 1 Remove the glass door 2 Hook the screen door...

Страница 19: ...ft and right side panels to show keyhole mounting 2 Open the left and right side faceplate panels of the faceplate 3 Mount the faceplate onto the unit by aligning the 4 key hole slots in the faceplate...

Страница 20: ...rom the sleeve and connect them to the wires from the unit as shown in diagram 10 9 Close the right side faceplate panel 10 Remove the remote receiver bracket from the left side of the unit by undoing...

Страница 21: ...12 and put back in place see diagram 13 NOTE Ensure connectors are tucked in behind the mounting bracket to allow the side faceplate panel to close easily Diagram 12 Diagram 13 15 Re install the remot...

Страница 22: ...soft surface to prevent scratching Backing Plate Installation Customize Backing Plate The inside of the backing plate may be cut as required using a metal cutting blade Do not cut the outside edges Th...

Страница 23: ...ight Corner Backing Plate 9 Place the right side corner backing plate over the top and right side backing plate Push in place to secure see diagram 5 Repeat for left side Completed Backing Plate Insta...

Страница 24: ...panels to show mounting of hearth trim a The Hearth Trim can be adjusted to custom fit an installation by pulling apart the top piece from the bottom piece b Cut the top of the bottom piece of the he...

Страница 25: ...y remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Fit log 2 711 into the pins on the rear log tray 2 711 3 Place log 2 714 on the base o...

Страница 26: ...g 2 713 into the pin on log 2 714 and rest the right side of the log on the burner plate pushing it against the tab 2 712 2 713 2 714 2 713 6 Place log 2 715 into the pin on log 2 712 and rest the rig...

Страница 27: ...e right side of the burner as shown 8 Fit log 2 716 into the pin on log 2 712 Right side of Burner 2 713 2 716 2 712 Also place a few embers along the burner tube next to log 2 713 Separate platinum e...

Страница 28: ...28 Regency L234 Direct Vent Gas Insert INSTALLATION Completed Log Set Installation 2 711 2 716 2 715 2 712 2 713 2 714...

Страница 29: ...surfaces and are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be p...

Страница 30: ...iring rate rate noted on label at 15 minutes 2 Ifrequired adjustingtheprimaryairtoensure that the flame does not carbon First allow the unit to burn for 15 min to stabilize 3 Check for proper draft CA...

Страница 31: ...seen when lighting the unit the logs have been incorrectly positioned 8 The unit should never be turned off and on again without a minimum of a 60 second wait LIGHTING PROCEDURE During the first few...

Страница 32: ...und when ON This sound will increase or decrease in volume depending on the speed setting of your fan speed control Burner Tray The burner tray is positioned directly under the burnertube s andlogsand...

Страница 33: ...ANCE CAUTION ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE AP...

Страница 34: ...Whileholdingthehookturn it upside down and place it into the middle opening on the top side mounting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 5 Remove the logs...

Страница 35: ...fan by sliding the fan forward and lift up and out 14 Remove the ground screw which holds the ground wire Ground Wire 15 Replace the fan NOTE Bendtheconnectorclipsdownbefore re installing the fan cov...

Страница 36: ...lace it into the middle opening on the top side mounting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 7 Disconnect the gas connection to the valve 8 Disconnect the...

Страница 37: ...ews Rear Log Tray Removed 14 Remove the 12 screws that hold the valve tray to the firebox and carefully pull out 15 Replace the valve 16 Reverse steps 14 1 11 Remove the burner by undoing the 3 screws...

Страница 38: ...el Set Standard Brown 536 902 Brick Panel Set Standard Red 9 Brick Panel Right 10 Brick Panel Left 11 Brick Panel Back 511 031 Brick Clip 12 536 523 Flue Adaptor Assembly 13 Valve Shield 14 536 091 Pi...

Страница 39: ...CEPLATE ASSEMBLY Part Description 60 536 918 Contemporary Faceplate 61 536 914 Contour Faceplate 62 910 246 Burner ON OFF Switch 63 910 330 Fan Speed Control 120 V 64 904 569 Fan Speed Control Knob 65...

Страница 40: ...Insert PARTS LIST BACKING PLATE HEARTH TRIM ASSEMBLY Part Description 536 922 Backing Plate 81 Left Side 82 Right Side 83 Top 84 Left Corner 85 Right Corner 536 940 Hearth Trim 86 Top 87 Bottom Not a...

Страница 41: ...Regency L234 Direct Vent Gas Insert 41 NOTES...

Страница 42: ...42 Regency L234 Direct Vent Gas Insert NOTES...

Страница 43: ...nsportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days...

Страница 44: ..._________________________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial...

Отзывы: