background image

 

 

 
IN 5H08/12/15/18 

- 15 - 

© Future Products Group 

 
Routine 

HEATED CABINETS 

 - 

CLEANING 

 
 

Schedules 

To maintain optimum performance, cleaning schedules must be regular and 
thorough.   

 

Inspection 

As part of the cleaning routine, the controls, mechanical parts and electrical 
wiring should be inspected for damage, deterioration or need of adjustment.  

 

Correction 

If any small faults are found, have them attended to promptly by a competent 
serviceman.  Don’t wait until they cause a complete breakdown. 

 

 

Содержание IN 5H08

Страница 1: ...Heated Cabinets...

Страница 2: ...e Products Group Limited All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying re...

Страница 3: ...Cabinet Layout 8 Tilt or Sliding Front Doors 8 Lighting 8 Square Glass Cabinets 8 Controls 9 Control Panel 9 Power Switch 9 Lights 9 Heating Controller 9 Preparation 10 Shelf Location and Ticketing 1...

Страница 4: ...ce with Local Requirements 16 Setting Up 16 Unpacking 16 Site Preparation 16 Cabinet Preparation 16 Tilt Door Adjustment 16 Location 17 Ventilation 17 Access 17 Power Supply 17 Voltage Rating 17 Suppl...

Страница 5: ...ovements 22 Ongoing Development 22 ELECTRICAL CIRCUIT DIAGRAMS 23 Model IN 5H08 23 Model IN 5H12 23 Model IN 5H15 24 Model IN 5H18 24 SPARE PARTS 25 Cabinet Serial Number 25 Location of Glass Parts 26...

Страница 6: ...w its recommendations The time taken will be well spent These instructions both general and technical tell you how to operate and look after your inline food service cabinet so that you can receive th...

Страница 7: ...age or malfunction resulting from the use of non FPG supplied spare parts Specific Exclusions The following are specifically excluded from warranty Breakage of glass or plastic components or the repla...

Страница 8: ...d rear of the cabinet The control equipment is housed in the base of the cabinet Lighting As standard all cabinets are fitted with high efficiency LED lighting strips in the ceiling of the cabinet and...

Страница 9: ...Switch To turn the power on rotate the mains switch in a clockwise direction Lights To turn the lights on rotate the light switch in a clockwise direction To avoid possible damage to the electronic ba...

Страница 10: ...lf Adjustment To move the shelf support brackets remove all the shelves and then remove the rear sliding doors Using two people one on each bracket slide the bracket upwards and disengage it from the...

Страница 11: ...NOT place aluminium foil on shelves or base trays This will disrupt the convection circulation of air and cause uneven heating Blockage of air vents may cause severe overheating of the cabinet base C...

Страница 12: ...Cabinet does not reach temperature One or more doors is open Close doors and re test temperature after thirty minutes Aluminium foil or product blocking vents or disrupting air circulation Remove foil...

Страница 13: ...stainless steel and aluminium surfaces will be damaged Glass All glass should be cleaned using a good quality glass cleaner and a clean cloth DO NOT clean glass with abrasive pads or cleaners e g Scot...

Страница 14: ...oapy water Do not use abrasive pads or cleaners e g Scotchbrite pads or Jif as these may damage surfaces Warning Dishwasher detergents will damage any anodised aluminium parts Tilt Door Glass Gently p...

Страница 15: ...ust be regular and thorough Inspection As part of the cleaning routine the controls mechanical parts and electrical wiring should be inspected for damage deterioration or need of adjustment Correction...

Страница 16: ...location and any bench cut outs are made to the precise measurements shown in the specifications section Position the cabinet in its allocated working position Use a spirit level to ensure the cabine...

Страница 17: ...the 1200 1500 and 1800 heated cabinets is more than 10 Amps and they cannot therefore be supplied by a standard 10 Amp plug and socket A warning label adjacent to the supply lead states the maximum c...

Страница 18: ...Lighting Components Before replacing an LED strip check that the power supply is working If there is no dc voltage at the output the power supply should be replaced Access to LED Strips The LED strip...

Страница 19: ...t towards the front of the cabinet until the terminals are clear lift it out of the well and replace it with a new one Tighten the brass retaining nuts to prevent unwanted movement of the element reco...

Страница 20: ...is fitted with a Qlon gasket along the top The gasket is foam filled and has a T section base which slides into an aluminium extrusion Gasket Replacement The aluminium extrusion is in two halves with...

Страница 21: ...ial Stainless steel Stainless steel Stainless steel Stainless steel Number of Shelves Three plus base Three plus base Three plus base Three plus base Display Area 1 15 m 2 1 8 m 2 2 3 m 2 2 7 m 2 Clim...

Страница 22: ...ectrical Equipment IEC 335 Heated Food Cabinets AS NZS 3820 Essential Safety Requirements AS NZS 4417 Marking of Electrical Products Performance Aspects The cabinet is HACCP compliant with the followi...

Страница 23: ...IN 5H08 12 15 18 23 Future Products Group ELECTRICAL CIRCUIT DIAGRAMS Model IN 5H08 Inline 5000 Series 800mm Heated Cabinet Model IN 5H12 Inline 5000 Series 1200mm Heated Cabinet...

Страница 24: ...t No 26108 Rev C December 2015 24 5000 Series Cabinets ELECTRICAL CIRCUIT DIAGRAMS Continued Model IN 5H15 Inline 5000 Series 1500mm Heated Cabinet Model IN 5H18 Inline 5000 Series 1800mm Heated Cabin...

Страница 25: ...ht Cover 1120mm Long Clear Polycarb 18113 Light Cover 720mm Long Clear Polycarb 18114 Top Light Replacement Kit for 5H08 Curved Square 69255 70441 Shelf Light Replacement Kit for 5H08 Curved Square 69...

Страница 26: ...l 800 Square Glass Cabinet 18891 Front Panel 1200 Square Glass Cabinet 19006 Front Panel 1500 Square Glass Cabinet 19008 Front Panel 1800 Square Glass Cabinet 19010 Top Panel 800 Square Glass Cabinet...

Страница 27: ...Feet These drawings show cabinets fitted with the standard 150mm tapered feet Alternative 100mm cylindrical feet are available for special orders These will reduce the overall cabinet height and also...

Страница 28: ...Part No 26108 Rev C December 2015 28 5000 Series Cabinets Sliding Door Cabinets Types IN 5H08 12 15...

Страница 29: ...IN 5H08 12 15 18 29 Future Products Group Tilt Door Cabinets Type IN 5H18...

Страница 30: ...Part No 26108 Rev C December 2015 30 5000 Series Cabinets Sliding Door Cabinets Type IN 5H18...

Страница 31: ...ture Products Group Square glass Cabinets Types IN 5H08 12 15 18 Because the front face of Square glass cabinets is vertical deeper shelves can be fitted in the upper two levels This increases the dis...

Страница 32: ...Part No 26108 Rev C December 2015...

Отзывы: