Refrigeration
REFRIGERATED CABINETS
-
SERVICING
Caution
DO NOT attempt to service the refrigeration equipment without isolating
the cabinet at the main switch or unplugging it from the wall.
Removable
Filters
The cabinet is fitted with a removable
filter, which will catch most of the dust and
fluff, before it reaches the condenser
radiator.
This are easily removed and should be
cleaned regularly.
Shake or vacuum off accumulated debris
and wash in warm soapy water.
Condenser
Radiator
For efficient refrigeration performance,
the condenser radiator must be kept
clean. Failure to do this will lead to a
build-up of dust, and restricted airflow will
prevent the unit from working properly.
The compressor may overheat and the
cabinet temperature may rise. Be careful
not to bend or damage the soft aluminium
fins when vacuuming the radiator. If the
fins are flattened, airflow will be restricted
and overheating will result.
Regular vacuuming will prevent a build-up of dust and fluff, but three monthly
service checks, by a refrigeration engineer, are mandatory. These should include
cleaning the condenser radiator using compressed air.
Access to
Refrigeration
Equipment
Removable panels, on the right and rear
of the cabinet, provide further access to
the refrigeration equipment.
Continued on next page
Содержание IL-C-DRW-A001
Страница 1: ...Refrigerated Milk Drawer...
Страница 33: ...IL C DRW A001 A003 33 Future Products Group MECHANICAL DRAWINGS Model IL C DRW A001...
Страница 34: ...Part No 26984 Rev C May 2018 34 Refrigerated Milk Drawer Model IL C DRW A003...
Страница 35: ...IL C DRW A001 A003 35 Future Products Group...