background image

NT301 OBDII/EOBD Code Reader User’s Guide_English Version_V1.00

2

One-Year Limited Warranty

Subject to the conditions of this limited warranty, Shenzhen Foxwell Technology Co., Ltd
(“FOXWELL”) warrants its customer that this product is free of defects in material and
workmanship at the time of its original purchase for a subsequent period of one (1) year.
In the event this product fails to operate under normal use, during the warranty period, due to
defects in materials and workmanship, FOXWELL will, at its sole option, either repair or replace
the product in accordance with the terms and conditions stipulated herein.

Terms and Conditions

1 If FOXWELL repairs or replaces the product, the repaired or replaced product shall be
warranted for the remaining time of the original warranty period. No charge will be made to the
customer for replacement parts or labor charges incurred by FOXWELL in repairing or replacing
the defective parts.
2 The customer shall have no coverage or benefits under this limited warranty if any of the
following conditions are applicable:
a) The product has been subjected to abnormal use, abnormal conditions, improper storage,
exposure to moisture or dampness, unauthorized modifications, unauthorized repair, misuse,
neglect, abuse, accident, alteration, improper installation, or other acts which are not the fault of
FOXWELL, including damage caused by shipping.
b) The Product has been damaged from external causes such as collision with an object, or from
fire, flooding, sand, dirt, windstorm, lightning, earthquake or damage from exposure to weather
conditions, an Act of God, or battery leakage, theft, blown fuse, improper use of any electrical
source, or the product was used in combination or connection with other product, attachments,
supplies or consumables not manufactured or distributed by FOXWELL.
3 The customer shall bear the cost of shipping the product to FOXWELL. And FOXWELL shall
bear the cost of shipping the product back to the customer after the completion of service under
this limited warranty.
4 FOXWELL does not warrant uninterrupted or error-free operation of the product. If a problem
develops during the limited warranty period, the consumer shall take the following step-by-step
procedure:
a) The customer shall return the product to the place of purchase for repair or replacement
processing, contact your local FOXWELL distributor or visit our website www.foxwelltech.com to
get further information.
b) The customer shall include a return address, daytime phone number and/or fax number,
complete description of the problem and original invoice specifying date of purchase and serial
number.
c) The customer will be billed for any parts or labor charges not covered by this limited warranty.
d) FOXWELL will repair the Product under the limited warranty within 30 days after receipt of the
product. If FOXWELL cannot perform repairs covered under this limited warranty within 30 days,
or after a reasonable number of attempts to repair the same defect, FOXWELL at its option, will
provide a replacement product or refund the purchase price of the product less a reasonable
amount for usage.
e) If the product is returned during the limited warranty period, but the problem with the product is
not covered under the terms and conditions of this limited warranty, the customer will be notified
and given an estimate of the charges the customer must pay to have the product repaired, with all
shipping charges billed to the customer. If the estimate is refused, the product will be returned
freight collect. If the product is returned after the expiration of the limited warranty period,
FOXWELL’ normal service policies shall apply and the customer will be responsible for all
shipping charges.
5 ANY IMPLIED WARRANTY OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR
PURPOSE OR USE, SHALL BE LIMITED TO THE DURATION OF THE FOREGOING LIMITED
WRITTEN WARRANTY. OTHERWISE, THE FOREGOING LIMITED WARRANTY IS THE
CONSUMER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED. FOXWELL SHALL NOT BE LIABLE FOR SPECIAL,
INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED

Содержание NT301

Страница 1: ...holders Copyright Information 2014 Shenzhen Foxwell Technology Co Ltd All rights reserved Disclaimer The information specifications and illustrations in this manual are based on the latest information...

Страница 2: ...fter the completion of service under this limited warranty 4 FOXWELL does not warrant uninterrupted or error free operation of the product If a problem develops during the limited warranty period the...

Страница 3: ...NY OTHER LEGAL OR EQUITABLE THEORY EVEN IF FOXWELL KNEW OF THE LIKELIHOOD OF SUCH DAMAGES FOXWELL SHALL NOT BE LIABLE FOR DELAY IN RENDERING SERVICE UNDER THE LIMITED WARRANTY OR LOSS OF USE DURING TH...

Страница 4: ...low all safety messages Do not route the test cable in a manner that would interfere with driving controls Do not exceed voltage limits between inputs specified in this user s manual Always wear ANSI...

Страница 5: ...3 TECHNICAL SPECIFICATIONS 9 3 GETTING STARTED 9 3 1 PROVIDING POWER TO CODE READER 9 3 1 1 Connecting to Vehicle Power 9 3 1 2 Connecting to Personal Computer with USB Cable 9 3 2 APPLICATION OVERVIE...

Страница 6: ...2 3 Allowed INC Monitors 37 7 2 4 Reset Factory Default 38 7 3 UNIT OF MEASURE 38 7 4 KEY BEEP SET 39 7 5 DIAG BEEP SET 41 7 6 TOOL SELF TEST 40 7 6 1 Display Test 41 7 6 2 Keypad Test 41 7 6 3 LED T...

Страница 7: ...options displays Menu options include Languages Configure monitors Unit of measure Key Beep Set Diag Beep Set Tool self test 1 2 2 Arrow Icon An arrow icon indicates a procedure Example To change men...

Страница 8: ...not run their diagnostic testing E Red LED Display indicates there are some problems in one or more of the vehicle s systems In this case the MIL lamp on the instrument panel is on F UP Key quick acce...

Страница 9: ...re 20 to 70 4 to 158 Power Supply 8 18V vehicle power Supported Protocols J1859 41 6 J1850 10 4 ISO9141 KWP2000 ISO 14230 and CAN Control Area Network ISO 11898 Dimensions L W H 145 94 32mm Weight 0 6...

Страница 10: ...ode reader Figure 3 1 Sample Home Screen 4 OBDII EOBD Operations OBD II EOBD menu lets you access all OBD service modes According to ISO 9141 2 ISO 14230 4 and SAE J1850 standards the OBD application...

Страница 11: ...t on the display as illustrated below Figure 4 1 Sample System Status Screen NOTE If vehicle is equipped with more than one computer module for example a powertrain control module PCM and a transmissi...

Страница 12: ...blinks Permanent Codes are DTCs that are confirmed and are retained in the non volatile memory of the computer until the appropriate monitor for each DTC has determined that the malfunction is no lon...

Страница 13: ...s and no vital information will be lost before clearing codes There are two ways to erase codes Press the Erase hot key to erase codes from home screen Traditional way select Erase Codes from the diag...

Страница 14: ...ata function allows real time viewing of the vehicle s electronic control unit s PID data including sensor data operation of switches solenoids and relays Menu options typically include Complete Data...

Страница 15: ...ER key to display the datastream screen Figure 4 10 Sample View Data Menu Screen 4 Scroll with the up and down arrow keys to scroll through data to select lines and left and right arrow keys to scroll...

Страница 16: ...list and focus on any suspicious or symptom specific data parameters To create a custom data list 1 Select Custom List from the menu and press the ENTER key Figure 4 13 Sample Live Data Menu Screen 2...

Страница 17: ...E There are two types of trigger methods used Manual Trigger triggers recording whenever operators press the ENTER key DTC trigger automatically triggers recording when a code is detected by vehicle D...

Страница 18: ...ata to set up Complete Data Set or Customer Data Set to record Figure 4 18 Sample Record Data Menu Screen 3 Scroll with the up and down arrow keys to pick a trigger mode and press the ENTER key to con...

Страница 19: ...h an asterisk was picked a message prompting to erase data displays Figure 4 21 Sample Erase Recording Screen 5 If the recording is to be overwrited selected Yes if data is not to be overwrited pick N...

Страница 20: ...and support a different number of PIDs Therefore the maximum number of frames that can be recorded varies The code reader keeps recording data until the memory is full the operator presses the BACK k...

Страница 21: ...ample Record Data Screen 3 Press the UP DOWN key to view recorded PIDs of each frame Press the BACK key to exit Figure 4 27 Sample Record Data Screen 4 4 View Freeze Frame Freeze Frame menu displays f...

Страница 22: ...ests on the emission system during normal driving conditions After a specific amount of drive time each monitor has specific driving conditions and time required the computer s monitors decide if the...

Страница 23: ...build in beeper When the LED is Green Indicates that engine systems are OK and working properply the number of Monitors equipped with the vehicle which have run and performed their self diagnostic tes...

Страница 24: ...1 Scroll with UP DOWN key to highlight I M Readiness from Diagnostic Menu and press the ENTER key If vehicle supports both types of monitors a screen for monitor type selection displays Select a monit...

Страница 25: ...hen selected via the menu but tested when engine operating conditions are within specified limits If the vehicle uses a controller area network CAN protocol to communicate this function is not support...

Страница 26: ...4 37 Sample data of 81 screen 5 Press the BACK key to exit and return 4 7 On Board Monitor Test The On Board Monitor Test function is useful after servicing or after clearing a vehicle ECU s memory It...

Страница 27: ...2 Depending on the protocol the vehicle used one of these 2 screens shows Figure 4 39 Sample Non CAN Vehicle Test Screen Or Figure 4 40 Sample CAN vehicle test screen 3 Use the UP DOWN key to highlig...

Страница 28: ...der User s Guide_English Version_V1 00 28 Figure 4 41 Sample Non CAN vehicle test screen For CAN vehicles test screen is illustrated as below Figure 4 42 Sample Can vehicle test screen 4 Press the BAC...

Страница 29: ...to highlight a system or component press the ENTER key to start test and the code reader displays the message Command Sent Figure 4 44 Sample Component test screen 3 Press the BACK key to exit and ret...

Страница 30: ...key Figure 4 45 Sample Diagnostic Menu Screen 2 Follow on screen instruction and send the command to read vehicle information A screen with a list of available options displays Figure 4 46 Sample Vehi...

Страница 31: ...ight Modules Present from Diagnostic Menu and press the ENTER key Figure 4 48 Sample Diagnostic Menu Screen 2 A screen with the module IDs and protocols displays Figure 4 49 Sample Module Present Scre...

Страница 32: ...ample DTC Lookup Screen 3 A screen with code number and its definition displays If definition could not be found SAE or Manufacturer Specific the code reader displays DTC definition not found Please r...

Страница 33: ...the ENTER key Details of the test record displays View and analysis the recorded information then press BACK to exit 7 System Setup This section illustrates how to program the code reader to meet your...

Страница 34: ...he ENTER key to confirm Press the BACK key to exit and return Figure 7 2 Sample Language Selection Screen 7 2 Configure Monitors This menu allows the users to configure the monitors required to test s...

Страница 35: ...ensive Component Non Continuous Monitors NOTE Non continuous monitors are different for spark ignition cars gasoline engines and compression ignition card diesel engines Spark ignition vehicles Gas Ca...

Страница 36: ...equired Monitors from menu and press the ENTER key to confirm 2 The custom monitors selection screen displays Figure 7 5 Sample Custom Monitors Selection Screen 3 Use the RIGHT key to select or desele...

Страница 37: ...election screen displays and Use the RIGHT key to select or deselect a monitor or press the LEFT key to deselect all the monitors Press the ENTER key to confirm and BACK key to cancel Figure7 8 Sample...

Страница 38: ...7 2 4 Reset Factory Default This menu will allow the users to restore the default configuration settings in the Configure Monitors menu and delete any customized settings In this case it will include...

Страница 39: ...reen 7 3 Unit of measure Unit of measure opens a dialog box that allows you to choose between US customary or metric units of measure To change the unit setup 1 Scroll the UP DOWN keys to highlight Un...

Страница 40: ...up Screen 2 Press the UP DOWN arrow key select an item and press the ENTER key to save and return Figure 7 15 Sample Beep Set Selection Screen 7 5 Diag Beep Set Key beep set opens a dialog box that al...

Страница 41: ...pad and LED are working correctly Typical menu includes Display Test Keypad Test LED Test 7 6 1 Display Test Selecting Display Test option opens a screen that allows you to check the functionality of...

Страница 42: ...keypad To test the keypad 1 Use the UP DOWN key to highlight Keyboard Test from Setup menu and press the ENTER key Figure 7 20 Sample Tool Self test Screen 2 Press any key to start test Key name or s...

Страница 43: ...s to select the desired LED lamps to check The LED should turn on off according to the selected commands Figure 7 23 Sample LED Test Screen 4 To quit the test press the BACK key 8 Tool Information Sel...

Страница 44: ...ctions Updating the Code Reader Printing Searching DTC Read the manuals Update tool settings 9 1 Updating the Code Reader NT301 is able to be updated to keep you stay current with the latest developme...

Страница 45: ...o different ways for you to update the device Update online With internet connection the tool NT Wonder automatically detects the software version of the code reader and read the latest software versi...

Страница 46: ...nstructed on page 44 of 9 1 Updating the Code Reader 2 Activate the application by clicking the Print Button from the menu Figure 9 4 Sample Printing Activation Function 3 Connect NT301 to computer wi...

Страница 47: ...7 Sample Printing Data Screen 7 With the printer correctly connected use the Print key to print the testing data Press the BACK key to return to home screen 9 3 Searching DTC Searching DTC option ope...

Страница 48: ...9 Sample User Manual Screen 9 5 Update Tool Settings Settings option opens a screen that allows you to set the language and style of the tool Still it offers the option for you to automatically check...

Отзывы: