AC Power
TB-1D AC power input terminal is shown below. Use maximum 14 gauge stranded wire only. Do not
use solid wire. Always connect to an earth ground.
Analog Output 4-20mA
The isolated 4-20mA output signal is provided at terminals on TB-1E. This output can drive a load of
up to 600 ohms. Connect the load device, matching polarity as indicated.
NOTE: Do not run line voltage and low level signal voltage in the same conduit.
110/220 VAC INPUT
4-20MA Analog Output
Figure 16
Figure 17
Installation (Electrical)
15
FX-1000p