F8L10GW-L Outdoor LoRa Gateway User Manual
Add:Floor
11,A06 building, No.370,Chengyi Street,Jimei District, Xiamen,China.
http://en.four-faith.com
Hotline:400-8838-199
Fax:(+86)0592-5912735
24
/
32
3.3.3 LoRa Application
Users can config the parameters according to the specific applications
Enable Lora
:
Enable or disable lora function
Work Mode:
2 kinds, TRNS
、
PRO,if using PRO mode, pls refer to the API user manual
Through Address
:
lora Transmission node number of the target device, the operating mode to the
broadcast 65535. if operating mode is set to the API set,this setting will be invalid, the transfer
destination address is determined by custom packet
Carrier Frequency
:
The physical frequency of the module. The band-width of LoRa are 410MHz
to 441MHz, 470MHz to 510MHz and 850MHz to 950MHz. The bit error rate is different from
each channel.Asuitable channel should be selected according to the application.
Received Interval
:
Each time it receives a packet by LoRa, the longest wait for the timeout, in
milliseconds, the input value must be in the range 1 to 999
Received data timeout
:
if the time exceed,the lora will restart itself
Communicate Mode
: Equipment transmission conversion: to support communication between
lora and serial port, network forwarding combination; Notice: about the serial
’
s communicate
parameter setting must trun on
“
serial applicaion
”
web page setting
RSPD
:
The Bit Rate is the speed of data transferring. The bigger the Bit Rate, the faster of
the data transfer data speed,6 speed levels are available , unit Kbps
Protocal type :
UDP(DTU)
:
Data transmit with UDP protocol , work as a DTU which has application protocol