background image

Press       to switch run/stop heating

For example:

Current temperature: 50.0

Press the run/stop key to start heating, it displays - - - - and the 

current temperature.

Operation

Display

OFF 

Current temperature

- - - - &

50.0

OFF

Press the run/stop key to start heating,

it displays the current temperature,

countdown is off
Press the run/stop key again, heating

stops, and the screen displays “OFF”

Operation

Display

50.0

37.0

Directly set the heating temperature you

require
Press the set key to save the value then

exit, it displays the current temperature/OFF

5.3. Heating temperature setting

Method 1: 

Directly press               to enter the temperature setting as

following steps:

For example: 

the current temperature is 37.0°C, and set the temperature 50.0°C

Method 2: 

Press         to enter the temperature setting sub-menu to adjust the

temperature as following steps:

For example:

the current temperature is 37.0°C, and set the temperature 50.0°C

8

The bath is in unheated status

Содержание Ironman III

Страница 1: ...Operating Instructions Water Bath WB301 Ironman...

Страница 2: ...ructions The appearance and specifications are subject to change without notice Contents Declaration of Conformity 1 Safety Instructions 2 Unpacking 3 Installation 4 Correct use 5 Operation 6 Calibrat...

Страница 3: ...ld read this manual carefully follow the instructions and procedures and be ware of all the cautions when using this instrument DECLARATION OF CONFORMITY This water bath complies with the relevant sta...

Страница 4: ...ion Surfaces can be hot during and after use Caution Socket must be earthed protective ground contact 2 UNPACKING Please unpack the device carefully and check it for damage It is important that any tr...

Страница 5: ...nts The water bath has three main components the bath the lid and the base tray The base tray fits into the bath with the feet downward so that it creates a gap between the bottom of the chamber and t...

Страница 6: ...ithout water Avoid using your bath without water in the chamber Dry start will affect the service life of the key component The bath has an inbuilt protection mechanism known as dry start protection w...

Страница 7: ...level and take reasonable precautions to prevent accidental spillage The drainage operation is as follows 1 Insert the drain pipe into the drain port according to the direction shown in the figure Dra...

Страница 8: ...e base tray can improve temperature control inside containers Don t put the containers or other items into the stainless steel chamber directly Avoid the containers or other items direct contact with...

Страница 9: ...FF Operation Display 50 0 37 0 Directly set the heating temperature you require Press the set key to save the value then exit it displays the current temperature OFF 5 3 Heating temperature setting Me...

Страница 10: ...presets The bath has 3 presets Temperature presets allow you to conveniently store or run bath temperature settings for you routinely use Before you can use presets you need to store the values you w...

Страница 11: ...n Display Running the preset as the following procedures For example run the preset P1 5 5 Switch between Fahrenheit Temperature F and Celsius Temperature C When the C indicator is on the unit of temp...

Страница 12: ...re and the alarm will be turned off 5 7 Setting the countdown timer The countdown timer range is 0 99H59min After the countdown is over an alarm will sound three times and the heating will stop OFF is...

Страница 13: ...er bath to 50 mm above the tray and place the thermometer in the center of the water bath 40 mm away from the tray 12 Operation Display When the countdown is 0 it displays and the current temperature...

Страница 14: ...een displays 40 0 C but the actual liquid temperature is 42 0 C After calibration the screen displays 41 8 C and the actual liquid temperature is 42 0 C High temperature point calibration For example...

Страница 15: ...the OTP setting value is too low Dry start alarm no water in the chamber or the water is less than the Min amount Symptom Action required Have a competent person check the temperature sensor or mother...

Страница 16: ...arts inside the unit 9 TECHNICAL DATA 10 WARRANTY You have purchased an original laboratory machine which meets the highest engineering and quality standards In accordance with our warranty conditions...

Страница 17: ...1 2 3 3 1 3 2 3 3 4 4 1 4 2 4 3 5 6 7 8 16 17 17 18 18 20 20 20 20 20 20 21 25 27 27 27 28...

Страница 18: ...17 2014 35 EU EN61010 1 2014 30 EU EN55011 B EN61326 1 YY91037 99...

Страница 19: ...18 1 2 Ironman 1 1 1 1 1...

Страница 20: ...19 3 3 1 3 2...

Страница 21: ...3 3 4 4 1 4 1 1 4 1 2 1 20...

Страница 22: ...2 4 1 3 60 4 1 4 4 2 4 2 1 21 C F...

Страница 23: ...22 4 2 3 50 0 37 0 55 0 37 0 1 4 2 4 50 0 37 0 OFF OFF 50 0 OFF OFF 4 2 2 OFF 50 0...

Страница 24: ...23 OFF 1 4 2 4 3 P1 50 0 37 0 P1 4 2 5 OFF OFF...

Страница 25: ...24 4 2 7 0 99 59 3 OFF 1 2 3 4 0 1 10 OFF...

Страница 26: ...25 4 2 8 4 3 4 3 1 10 1 C 30 50MM 40MM 4 3 2 LCP 30 40 HCP 55 40 0 42 0 41 8 42 0 00 00 01 00 01 00 01 10 01 10 0 0 10S...

Страница 27: ...26 5s 95 98 0 97 7 98 0 5s...

Страница 28: ...27 5 6 7 1 OTP 2 OTP 1 2 OTP W min mm L Kg lronman AC100 120V AC200 240V 50 60Hz 1000 5 99 9 0 3 0 1 0 99 59 348 349 427 13 7 4...

Страница 29: ...8 2 28 3 7 915013000...

Отзывы: