CAUTION:

Make sure the air flow around the front, sides, and back of the device is not restricted.

Lifting Precautions

WARNING: Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming 
unstable or falling over. 

WARNING: Do not use the handles on the power supply units to lift or carry a Foundry device.

WARNING: Mount the devices you install in a rack or cabinet as low as possible.  Place the heaviest device at 
the bottom and progressively place lighter devices above.

Power Precautions

CAUTION:

Use a separate branch circuit for each AC power cord, which provides redundancy in case one of the 

circuits fails.

CAUTION:

Ensure that the device does not overload the power circuits, wiring, and over-current protection.  To 

determine the possibility of overloading the supply circuits, add the ampere (amp) ratings of all devices installed 
on the same circuit as the device.  Compare this total with the rating limit for the circuit.  The maximum ampere rat-
ings are usually printed on the devices near the input power connectors.

CAUTION:

All devices with DC power supplies are intended for installation in restricted access areas only.  A 

restricted access area is where access can be gained only by service personnel through the use of a special tool, 
lock and key, or other means of security, and is controlled by the authority responsible for the location.  

CAUTION:

For the DC input circuit to a ServerIron 4G Series, (DC power supply part number RPS5DC and 

RPS-X424-DC), make sure there is a 10-amp listed circuit breaker, minimum -48VDC, double pole, on the input to 
the terminal block.  The input wiring for connection to the product should be Listed copper wire, 14 AWG, marked 
VW-1, and rated 90 degrees Celsius.

CAUTION:

Make sure you insert the power supply right-side up.  It is possible to insert the supply upside down, 

although the supply will not engage with the power backplane when upside down.  The power supply is right-side 
up when the power connector is on the left and the fan vent is on the right.

CAUTION:

Remove the power cord from a power supply before you install it in or remove it from the device.  

Otherwise, the power supply or the device could be damaged as a result.  (The device can be running while a 
power supply is being installed or removed, but the power supply itself should not be connected to a power 
source.)

WARNING: Disconnect the power cord from all power sources to completely remove power from the device. 

WARNING: Make sure to choose the appropriate circuit device depending on the number of AC power supplies 
installed in the chassis. The minimum current draw for the system is one AC power supply. 

WARNING: Power supplies are hot swappable.  However, Foundry Networks recommends that you disconnect 
the power supply from AC power before installing or removing the supply.  The device can be running while a 
power supply is being installed or removed, but the power supply itself should not be connected to a power source.  
Otherwise, you could be injured or the power supply or other parts of the device could be damaged. 

Содержание ServerIron 4G

Страница 1: ...e eCommerce and service provider sites ServerIron 4G Series highlights include ASIC Based Application Processors Choice of non SSL and SSL Integrated switches Hardware SSL Acceleration ServerIron 4G S...

Страница 2: ...ponents This section describes hardware components that are common to the ServerIron 4G Series SSL and non SSL Stackable device switches Front Panel Figure 4 4 on page 4 3 shows the ServerIron 4G Seri...

Страница 3: ...tes power supply is not powered on or not present PS2 Green ON Indicates power supply is powered on OFF Indicates power supply is not powered on or not present BP Out Green ON Indicates BP is transmit...

Страница 4: ...of the other fan The following fan speeds are available low medium high You can change the settings of the temperature thresholds using the following command FastIron fan speed lo Syntax fan speed lo...

Страница 5: ...section describes the procedures required to prepare the site for installatoin Cabling Infrastructure Ensure that the proper cabling is installed in the site See Technical Specifications on page 4 21...

Страница 6: ...supply it might be easier to install it before mounting the device See Installing a Redundant Power Supply on page 4 8 3 Install the device on a desktop on the wall or in an equipment rack See Install...

Страница 7: ...DC input circuit to a ServerIron 4G Series DC power supply part number RPS5DC and RPS X424 DC make sure there is a 10 amp listed circuit breaker minimum 48VDC double pole on the input to the terminal...

Страница 8: ...r supply locking screw located in the center rear of the device illustrated below 2 If the empty power supply bay has a cover plate press inward on the two latches near the edges of the cover plate to...

Страница 9: ...tely in the slot so that the connectors on the back of the supply are fully engaged with the pins on the power backplane CAUTION Make sure you insert the power supply right side up It is possible to i...

Страница 10: ...as illustrated in Figure 4 7 on page 4 10 4 Proceed to Powering On the System on page 4 10 Figure 4 7 Installing the Device in a Rack Powering On the System After you complete the physical installati...

Страница 11: ...is your assurance that the power cord can be used safely with the device 4 Verify that the LED for each power supply is a solid green 5 Verify proper operation by observing the LEDs All the port LEDs...

Страница 12: ...sion parameters as follows Baud 9600 bps Data bits 8 Parity None Stop bits 1 Flow control None When you establish the serial connection to the system press Enter to display the CLI prompt in the termi...

Страница 13: ...a Terminal or PC Assigning Permanent Passwords By default the CLI is not protected by passwords To secure CLI access Foundry strongly recommends assigning passwords NOTE You cannot assign a password...

Страница 14: ...t enter the following command to change to the Privileged level of the EXEC mode FastIron enable 2 Access the CONFIG level of the CLI by entering the following command FastIron configure terminal Fast...

Страница 15: ...fault the CLI displays network masks in classical IP address format example 255 255 255 0 You can change the display to the prefix format NOTE If your network uses a BootStrap Protocol BootP server or...

Страница 16: ...r switches and routers via fiber ports See Connecting to a Fiber Port on page 4 16 Automatic MDI MDIX Detection All 100 1000 Ethernet Copper ports on the Foundry FastIron devices support automatic Med...

Страница 17: ...the Fiber Optic Connectors on page 4 17 3 Gently insert the cable connector s a tab on each connector should face upward into the port connector s until the tabs lock into place 4 Observe the link and...

Страница 18: ...perating correctly Verify that the transmit port on the Foundry device is connected to the receive port on the other network device and that the receive port on the Foundry device is connected to the...

Страница 19: ...is connected to the transmit port on the connected device Verify that the port has not been disabled through a configuration change You can use the CLI If you have configured an IP address on the dev...

Страница 20: ...at any CLI level Changing the Temperature Warning Level The Foundry device sends a warning message whenever the device s internal temperature reaches the default or configured warning temperature The...

Страница 21: ...e To do so enter the following command at any level of the CLI Syntax show cpu The CPU Usage field shows the percentage of management module CPU used by each task The total CPU usage may not add up to...

Страница 22: ...agnetic Emission ICES 003 Electromagnetic Emission FCC Class A EN 55022 CISPR 22 Class A VCCI Class A EN 61000 3 2 Power Line Harmonics EN 61000 3 3 Voltage Fluctuation Flicker EN 61000 6 3 Electromag...

Страница 23: ...d Weight of Chassis Height Width Depth Weight 2 60 in 6 6 cm 17 63 in 44 8 cm 19 6 in 47 2 cm 25 35 lbs 11 5 kg fully loaded including dual redundant power supplies 17 5 lbs 7 94 kg empty 4 lbs 18 kg...

Страница 24: ...be required to correct the interference at their own expense CAUTION Changes or modifications made to this device which are not expressly approved by Foundry Net works could void the user s authority...

Страница 25: ...PS5DC CISPR 22 Class A FCC Class A VCCI Class A IC ICES 003 Class A Canada EN55022 Class A Harmonic Current Emissions Class A EN61000 3 2 with Amendment 14 1999 Voltage Fluctuations and Flicker EN6100...

Страница 26: ...0 95 non condensing Operating altitude up to 10 000 feet above sea level Operating noise 47 dB A Storage temperature 40 to 185 F 40 to 85 C Storage altitude up to 15 000 feet above sea level Cooling...

Отзывы: