67
4.11.3 Interval-temperature alarm
Choose “
” for ‘interval-temperature’ color alarm
1. The temperature areas that exceed a certain threshold are displayed with
yellow color, emphasizing regions that are between set thresholds. Under this
palette, temperature scale change mode is not available.
2. The value in the upper right corner indicates the current alarming threshold.
The alarm area is adjustable by touching the screen (which will turn it blue)
and by pressing up and down keys. The overall image areas display will
change according to the dynamic palette on the right side.
3. Touch the number icon’s value on the top-right corner to turn it blue, and
press up or lower direction keys to adjust temperature values. Pressing left or
right direction keys/touching on the other part of the screen/pressing ‘return’
key to turn it white. After turning white, pressing on the up/down direction
keys cannot adjust the value.