- 31 -
• A curving and long ducting run should be
avoided, as it will lower the performance of
the range hood.
• Strictly seal the connection between the duct
and duct hole with duct tape. Ensure that the
connection between the duct and the duct cover
is secure, and seal it with aluminum tape.
• A small duct hole will lower the performance
of the range hood. Therefore, it is highly
recommended that you cut a duct hole equal
to or larger than 6"(152.4mm) of the size.
• The bolts used in this product are metric-size
bolts, please do not apply any unqualified
bolts.
6.2 Product Dimensions
Max 29"
(735mm)
Min 15"
(380mm)
10 7/8"
(275mm)
17 7/16
"(442mm)
18 1/4"
(462mm)
13"
(330mm)
29 7/8"
(758mm)
Wall Preparation
The wall should be strong enough to support the
range hood. As for hollow wall or hollow plate, The
minimum thickness of the lumber should be 13/16"
(30mm). As for concrete wall, the installation can be
directly operated. The range hood should be firmly
fixed on the wall.
Ductwork Installation
Risk of Injury:
• Unplug the appliance from the mains or switch
off the circuit breaker in the fuse box before
installation, cleaning, maintenance and repair
in order to avoid electric shock.
• The range hood may have sharp edges. Be
careful to avoid cuts and abrasions during
installation and cleaning. Do wear qualified
protective gloves.
installation. Make sure to use the expansion
tube and expansion bolt provided by our
company, in case the range hood falls
down accidentally. The hole drilled into the
wall should precisely match the size of the
expansion tube, otherwise the range hood will
not be properly secured to the wall and may
fall down.
3. The range hood should be connected to a
standard power socket with safe grounding.
The midway connection, prolonged electric
line or multi-socket wiring may cause electric
shock, overheating and even fire.
Power off before wiring and make sure
proper measures have been taken to avoid
unexpected connection.
4.
During installation, switch off the circuit
breaker in the fuse box during installation.
If the supply cord is damaged, it must be
replaced by a special cord or assembly
available from the manufacturer or its service
agent.
5. The appliance should only be installed,
removed and maintained by qualified
technicians to prevent risks like electric
shocks, falling or fires from occurring.
Risk of Injury:
• Unplug the appliance from the mains or switch
off the circuit breaker in the fuse box before
installation, cleaning, maintenance and repair
in order to avoid electric shock.
• The range hood may have sharp edges. Be
careful to avoid cuts and abrasions during
installation and cleaning. Do wear qualified
protective gloves.
Warning Before Installation
• Prior to installation, ensure that the exhaust
outlet is free of debris, as they may damage
the range hood.
• A straight and short ducting run will ensure a
high performance of the range hood.