background image

 

Issue Date: 7-21-03       Rev. Date: 9-15-03       Rev. Level: 03       ECN: GP-5005       OIPM P/N: 3420367       

Page 7 of 7

 

 
 

  MAINTENANCE

 

 

 

 
 
 

 

 

1. 

Always disconnect heater from power 
supply before performing any 
maintenance or service

 

2.  Periodically clean the reflector with a 

dampened soft cloth using mild 
detergent.  Rinse with water and wipe 
dry with a clean soft cloth. 

 

ELECTRICAL SHOCK 
HAZARD 

 

• 

Serious injury or death 
may occur. 

 

• 

Disconnect from electrical 
supply before installing or 
servicing this heater. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   TROUBLESHOOTING

 
 

 

SYMPTOM POSSIBLE 

CAUSE(S) 

CORRECTIVE 

ACTION 

 

Element does not energize. 
 
 
Not enough heat. 
 
 
 
Too much heat. 
 
 
Hot spot in tube.

 

 

1. Defective 

element

2. Improper 

connection 

 
1.  Heater too small for application 
2.  Heater mounted too high or too far. 
 
 
1.  Heater too large for application 
2.  Heater mounted too low or too close. 
 
1.  Heater is not level. 
2.  Grease or moisture on tube. 

 

 

1. Replace 

element. 

2.  Check connection to power outlet. 

 

 
1.  Add additional heater(s) 
2.  Decrease mounting height or 

distance.  

 
1.  Replace with smaller heater. 
2.  Increase mounting height or distance. 
 
1.  Adjust to a level mount. 
2.  Clean tube-replace if problem 

persists. 

 

   LIMITED WARRANTY

The obligation of Fostoria Industries, Inc. under the terms of this warranty, shall be to
supply a new part, repair of defective part, or a refund, at the company’s option with no
cost to owner for the new or repaired part. Such parts are to be returned to the factory, or
such other location as the company may designate. This warranty does not obligate
Fostoria Industries, Inc. to bear the cost of labor in replacing any assembly, unit or
component part thereof, nor does the company assume any liability for secondary
charges, expenses for installing or removal, or any other consequential losses. The
company’s maximum liability shall not in any case exceed the list price for the product
claimed to be defective. 
 
The warranty shall not apply to any product or parts of products which have been repaired 
or altered outside of Seller’s factory in any manner. Warranty is void on products that have 
been determined to have been subjected to misuse, negligence or accident or which have 
been used in a manner contrary to Seller’s instructions.

 

The warranty herein set forth is in lieu of all other warranties expressed or
implied. 
 
Fostoria Industries, Inc. of Fostoria, Ohio 44830, warrants its products to the
owner against defects in material and workmanship for a twelve (12) month
period under normal use and service following date of manufacture or installation
when proof of such is provided to seller. 
 
This Warranty requires that the owner, or his agent, install the equipment in 
accordance with the National Electrical Code, any other applicable heating or 
electrical codes and the manufacturer’s installation instructions. It further requires 
that he perform reasonable and necessary maintenance on the unit. The 
company is not liable for abuse or misuse of product as may be finally 
determined by the company.

 

FOSTORIA INDUSTRIES, INC. - P.O. Box 986, Fostoria, Ohio 44830-0986 - (419) 435-9201

 

Содержание OCH–46-120V

Страница 1: ...N GP 5005 OIPM P N 3420367 Page 1 of 7 IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible Read understand and follow all safety information and instructions in this manual before using or servicing this product Retain these instructions for future reference CONTENTS Specifications Page 2 Tube Installation Page 3 Heater Installation Page 3 4 Wiring Page 5 Replacement Parts Page 6 ...

Страница 2: ...ion box adds 2 384 to Dim A Model P N Tube P N Watts Volts Amps Cordset Dim A Dim B Dim C OCH 46 120V 04804402 04432302 1500 120 12 5 YES 42 0 5 375 6 500 OCH 46 208V 04804502 04418102 2000 208 9 6 42 0 5 375 6 500 OCH 46 240V 04804602 04418002 2000 240 8 3 YES 42 0 5 375 6 500 OCH 46 277V 04804702 04419302 2000 277 7 2 NO 42 0 5 375 6 500 OCH 46 120V SS 04805202 04432302 1500 120 12 5 YES 42 0 5 ...

Страница 3: ...tubes are horizontal Failure to do this may cause the heating element within the tube to sag and cause premature burnout ELECTRICAL SHOCK HAZARD Serious injury or death may occur Disconnect from electrical supply before installing or servicing this heater HEATER INSTALLATION These heaters MUST be installed as follows 12 inches minimum from a vertical surface 24 inches minimum from ANY combustible ...

Страница 4: ...is shipped complete with hardware for overhead suspension in two different ways 1 In the hardware bag shipped with your heater you will find two adjustable mounting brackets and fastening screws that should be assembled as shown in figure 1 Once assembled to the heater and mounted these brackets enable the heater to be angled in 15 degree increments up to 45 degrees The mounting centers for the br...

Страница 5: ...upply Hi temp wires INTERNAL WIRING DIAGRAM OCH heaters are equipped with two 12 gauge hi temperature silicone lead wires and a ground termination For field wiring use 12 ga 90º C rated wire and connect to the two lead wires in the junction box with wire nuts Make sure ground wire is properly connected to the fixture s ground terminal located in the junction box Make certain the power source confo...

Страница 6: ...RIPTION 1 1 SEE HOUSING TABLE HOUSING 2 1 8561700 COVER JUNCTION BOX 3 1 8561400 8560300 WIRE CHANNEL OCH 46 series WIRE CHANNEL OCH 57 series 4 1 3104600 JUNCTION BOX 5 1 SEE CORDSET TABLE CORDSET STRAIN RELIEF not shown 6 2 8561200 END CAP 7 10 2326500 SCR HWHS 8 32 x 3 8 8 1 8521500 NIPPLE CHASE not shown 9 1 8500739 SPACER not shown 10 1 8561800 8560400 REFLECTOR OCH 46 series REFLECTOR OCH 57...

Страница 7: ...ocation as the company may designate This warranty does not obligate Fostoria Industries Inc to bear the cost of labor in replacing any assembly unit or component part thereof nor does the company assume any liability for secondary charges expenses for installing or removal or any other consequential losses The company s maximum liability shall not in any case exceed the list price for the product...

Отзывы: