Issue Date: 12-02-97      Rev. Date: 05-05-08        Rev. Level: 06        EC0: 1-5888                OIPM P/N 8300       Page 3 of 6

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Part No. 

for 

FFH-512A

 

08838999 

08515100 

 

08515400 
08515229 

 

03193200 

 

03171300 

 


-

 

 
 

 

 

REPLACEMENT PARTS LIST and EXPLODED VIEW 

REF. 

NO. 

 

1. 
2. 
3. 

 

4. 
5. 
6. 

 

6. 

 

7. 
8. 
9. 

 

10. 
11.

 

 

 

DESCRIPTION 

 

Housing assembly 
Wireway cover 
Reflector 
 
End cap 
Quartz tube guard 
SO3 Socket w/o shunt 
 
Ceramic insulator 
 
Toggle switch 
18-3 Cordset 8' 
PHM P Screw 10-32 x1” 
 
Hex nut 10-32 
Wire nut

 

 

 

Part No. 

for 

FFH-912B

 

08050514 
08060114 
08060300 

 

08060400 
08060529 
07715002 

 

 

03110300 
03171300 
03401939 

 

1041 
3605

 

 

 

 

QTY. 

 



 



 

 



 


1

 

 

 

Part No. 

for 

FFH-512A

 

43882-001 

03440300 

 

04400802 

 

32113-002 

 

03190700 

5081 

32110-001 

28942-001

 

 

REF. 

NO. 

 

12. 
13. 
14. 

 

    15. 

 

16. 

 

17. 
18. 

 

19. 
20. 
21. 
22. 
23.

 

 

 

 

DESCRIPTION 

 

PHD P Screw #8-32 X3/8" 
Strain relief 
Jack chain (hdwr. pkg.) 

Two 4' chains 

Quartz tube 450W/120V 
Quartz tube 550W/120V 
Wire channel 
 
Socket shield 
18 ga. silicone wire 

(not shown) 

Sleeving (not shown) 
HHD Screw 8 x 1/2" 
PHM P Screw 10-32 5/16” 
Socket shunt (not shown) 
#10 ext. tooth lockwasher 

Part No. 

for 

FFH-912B

 

3602 

43882-001 

03452600 

 

04403502 

-

 

08050300 

 

08050200 

 

03190700 
03470800 

07711600

 

 

 

QTY. 

 



 



 


 





2

 

Figure 4 

Model FFH-512A 

Figure 3 

Model FFH-912B 

Top View 

13 

12 

12 

12 

10 

15 

11 

12 

10 

17 

13 

21 

23 

20 

21 

15 

21 

20 

23 

21 

 

 

 

Содержание FFH-912B

Страница 1: ...ructions before using this heater WARNING DO NOT DEPEND UPON A THERMOSTAT OR OTHER SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE HEATER ALWAYS UNPLUG THE HEATER FAILURE TO DO SO COULD RESULT IN FATAL ELECTRIC SHOCK 1 This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces Keep combustible materials such as furniture pillows bedding p...

Страница 2: ... dry with a clean soft cloth Periodically wipe the quartz tube s with alcohol and a clean soft cloth Allow to dry Repair or replace damaged cordsets immediately INSTALLATION OF HEATING ELEMENT MODEL FFH 512A Refer to Figure 2 1 Loosen screws on ceramic insulators 2 Position quartz tube in slots 3 Carefully wrap pigtail of quartz tube clockwise around screw and tighten screw Be sure to leave some s...

Страница 3: ... QTY 1 1 1 2 1 2 2 2 1 4 4 1 Part No for FFH 512A 43882 001 03440300 04400802 32113 002 03190700 5081 32110 001 28942 001 REF NO 12 13 14 15 16 17 18 19 20 21 22 23 DESCRIPTION PHD P Screw 8 32 X3 8 Strain relief Jack chain hdwr pkg Two 4 chains Quartz tube 450W 120V Quartz tube 550W 120V Wire channel Socket shield 18 ga silicone wire not shown Sleeving not shown HHD Screw 8 x 1 2 PHM P Screw 10 3...

Страница 4: ...eado Suspensión Dos cadenas de gato de 1 2 metros 4 pies Cordón eléctrico 18 3 de 2 4 metros 8 pies con clavija Nema 5 15P Fuente de electricidad 120 V 60 Hz IMPORTANTE INFORMACIÓN DE SEGURIDAD 1 ADVERTENCIA EVITE USAR TERMOSTATOS O TODO TIPO DE INTERRUPTOR COMO MEDIO ÚNICO DE DESCONECTAR LA ALIMENTACIÓN ELÉCTRICA AL INSTALAR O DAR SERVICIO AL CALENTADOR SIEMPRE DESCONECTE EL INTERRUPTOR PRINCIPAL...

Страница 5: ... presentes pueden aumentarse o disminuirse apagando o encendiendo los elementos calefactores El modelo FFH 912B cuenta con dos fuentes caloríficas tubos de cuarzo y apagando un tubo no se afecta la dirección del calor El ciclado constituye una forma alternativa al apagado y encendido de los tubos y se logra fácilmente mediante un controlador de entrada o un temporizador de porcentaje Ambos disposi...

Страница 6: ...nillo PHM 10 32 x 1 Tuerca hexagonal 10 32 Tuerca sujetacables Pieza No para FFH 912B 08050514 08060114 08060300 08060400 08060529 07715002 03110300 03171300 03401939 1041 3605 CANT 1 1 1 2 1 2 2 2 1 4 4 1 Pieza No para FFH 512A 43882 001 03440300 04400802 32113 002 03190700 5081 32110 001 28942 001 NO REF 12 13 14 15 16 17 18 19 20 21 22 23 DESCRIPCIÓN Tornillo PHD P 8 32 x 3 8 Protección contra ...

Отзывы: